开发美白霜中的胶态银基汞传感器

Muhammad Hilmi Afthoni, Sherly Yunita, Eva Monica
{"title":"开发美白霜中的胶态银基汞传感器","authors":"Muhammad Hilmi Afthoni, Sherly Yunita, Eva Monica","doi":"10.20473/jfiki.v10i32023.272-279","DOIUrl":null,"url":null,"abstract":"Background: Mercury, a hazardous heavy metal known for its toxicity to the human body, finds application in cosmetics due to its capacity to inhibit melanin formation. Traditional mercury analysis relies on resource-intensive and time-consuming instrumentation. Objective: This study aims to devise cost-effective and practical sensors for mercury detection. Methods: The sensor development process involves immobilizing the sensor onto paper, reacting it with mercury, scanning the outcome using a scanner, and subsequently quantifying RGB values using the ImageJ software. Results: Optimization of reagent concentrations gave a ratio of methylene blue, AgNO3, gallic acid, and ascorbic acid at 0.5:7:1.5:1 generating the best results. Additionally, pH optimization within the range of 5 to 9 demonstrates stability without necessitating the inclusion of a buffer solution. Notably, the blue variant exhibits superior responsiveness during concentration optimization. Characterization of the sensor reveals a response time of 3 minutes and minimal interference of 2.145% from other substances. The sensor exhibits a linearity range of 0.5-250 ppm, regression equation y = 8.603x + 21.124, an R-value of 0.994, and an exceedingly low p-value of 6.9924589548512 x 10-9. The sensor boasts a limit of detection (LOD) of 0.206 and a limit of quantification (LOQ) of 0.265, indicative of its precision. Further assessments reveal a percent relative standard deviation (% RSD) precision of 2.017% and a recovery rate of 96.14%. Conclusion: The sensor has exhibited stability for over one month under room temperature storage conditions. A comparison between the UV-Vis spectrophotometer and the sensor signifies no significant difference between the two methods.","PeriodicalId":17684,"journal":{"name":"JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Colloidal Silver-based Mercury Sensors in Whitening Cream\",\"authors\":\"Muhammad Hilmi Afthoni, Sherly Yunita, Eva Monica\",\"doi\":\"10.20473/jfiki.v10i32023.272-279\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Mercury, a hazardous heavy metal known for its toxicity to the human body, finds application in cosmetics due to its capacity to inhibit melanin formation. Traditional mercury analysis relies on resource-intensive and time-consuming instrumentation. Objective: This study aims to devise cost-effective and practical sensors for mercury detection. Methods: The sensor development process involves immobilizing the sensor onto paper, reacting it with mercury, scanning the outcome using a scanner, and subsequently quantifying RGB values using the ImageJ software. Results: Optimization of reagent concentrations gave a ratio of methylene blue, AgNO3, gallic acid, and ascorbic acid at 0.5:7:1.5:1 generating the best results. Additionally, pH optimization within the range of 5 to 9 demonstrates stability without necessitating the inclusion of a buffer solution. Notably, the blue variant exhibits superior responsiveness during concentration optimization. Characterization of the sensor reveals a response time of 3 minutes and minimal interference of 2.145% from other substances. The sensor exhibits a linearity range of 0.5-250 ppm, regression equation y = 8.603x + 21.124, an R-value of 0.994, and an exceedingly low p-value of 6.9924589548512 x 10-9. The sensor boasts a limit of detection (LOD) of 0.206 and a limit of quantification (LOQ) of 0.265, indicative of its precision. Further assessments reveal a percent relative standard deviation (% RSD) precision of 2.017% and a recovery rate of 96.14%. Conclusion: The sensor has exhibited stability for over one month under room temperature storage conditions. A comparison between the UV-Vis spectrophotometer and the sensor signifies no significant difference between the two methods.\",\"PeriodicalId\":17684,\"journal\":{\"name\":\"JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20473/jfiki.v10i32023.272-279\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20473/jfiki.v10i32023.272-279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:汞是一种以对人体有毒而著称的有害重金属,因其具有抑制黑色素形成的能力而被应用于化妆品中。传统的汞分析依赖于耗费大量资源和时间的仪器。研究目的本研究旨在设计经济实用的汞检测传感器。方法:传感器的开发过程包括将传感器固定在纸上,与汞反应,使用扫描仪扫描结果,然后使用 ImageJ 软件量化 RGB 值。结果:通过优化试剂浓度,亚甲基蓝、AgNO3、没食子酸和抗坏血酸的比例为 0.5:7:1.5:1,结果最佳。此外,pH 值在 5 至 9 范围内的优化显示了稳定性,无需加入缓冲溶液。值得注意的是,蓝色变体在浓度优化过程中表现出更高的响应性。传感器的特性表明,其响应时间为 3 分钟,受其他物质的干扰极小,仅为 2.145%。传感器的线性范围为 0.5-250 ppm,回归方程为 y = 8.603x + 21.124,R 值为 0.994,P 值为 6.9924589548512 x 10-9,非常低。该传感器的检测限 (LOD) 为 0.206,定量限 (LOQ) 为 0.265,这表明了它的精确度。进一步评估显示,相对标准偏差 (RSD) 百分比精度为 2.017%,回收率为 96.14%。结论该传感器在室温储存条件下的稳定性超过一个月。紫外可见分光光度计与传感器之间的比较表明,两种方法之间没有明显差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of Colloidal Silver-based Mercury Sensors in Whitening Cream
Background: Mercury, a hazardous heavy metal known for its toxicity to the human body, finds application in cosmetics due to its capacity to inhibit melanin formation. Traditional mercury analysis relies on resource-intensive and time-consuming instrumentation. Objective: This study aims to devise cost-effective and practical sensors for mercury detection. Methods: The sensor development process involves immobilizing the sensor onto paper, reacting it with mercury, scanning the outcome using a scanner, and subsequently quantifying RGB values using the ImageJ software. Results: Optimization of reagent concentrations gave a ratio of methylene blue, AgNO3, gallic acid, and ascorbic acid at 0.5:7:1.5:1 generating the best results. Additionally, pH optimization within the range of 5 to 9 demonstrates stability without necessitating the inclusion of a buffer solution. Notably, the blue variant exhibits superior responsiveness during concentration optimization. Characterization of the sensor reveals a response time of 3 minutes and minimal interference of 2.145% from other substances. The sensor exhibits a linearity range of 0.5-250 ppm, regression equation y = 8.603x + 21.124, an R-value of 0.994, and an exceedingly low p-value of 6.9924589548512 x 10-9. The sensor boasts a limit of detection (LOD) of 0.206 and a limit of quantification (LOQ) of 0.265, indicative of its precision. Further assessments reveal a percent relative standard deviation (% RSD) precision of 2.017% and a recovery rate of 96.14%. Conclusion: The sensor has exhibited stability for over one month under room temperature storage conditions. A comparison between the UV-Vis spectrophotometer and the sensor signifies no significant difference between the two methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
26
审稿时长
12 weeks
期刊最新文献
Characterization of microencapsulated Saga Leaves Extract (Abrus precatorius L.) and Analgetic Activity Tests in Male Mice (Mus musculus) Formulation and Characterization of Instant Powder Combination of Ginger, Bangle, and Lemon Extract as an Antioxidant Analysis of Molecular Docking and Dynamics Simulation of Mahogany (Swietenia macrophylla King) Compounds Against the PLpro Enzyme SARS-COV-2 The Development and Validation of The Indonesian Insulin Adherence Influence Factor Questionnaire (IIAIFQ) Effect of CaCl2 Crosslinker Concentration On The Characteristics, Release and Stability of Ciprofloxacin HCl-Alginate-Carrageenan Microspheres
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1