{"title":"采用辐照后实验数据集的蒙特卡罗燃料组件模型验证","authors":"Lorenzo Loi, A. Cammi, S. Lorenzi, C. Introini","doi":"10.1115/1.4064308","DOIUrl":null,"url":null,"abstract":"\n Within a hybrid energy system, it is fundamental to have accurate and reliable computational tools to predict the plants; behaviour under different operating conditions; compared to other energy sources, analysis methods for nuclear systems must provide detailed information on reactor criticality and fuel evolution. Thanks to the advancements in computational hardware, using three-dimensional codes to obtain a local description of the reactor core has now become feasible both for deterministic codes and for Monte Carlo (MC) codes. Those computational methods must be compared with experimental measurements to assess their reliability. For this reason, the 3D MC code SERPENT is currently being validated for Light Water Reactor (LWR) fuel cycle simulations. This work will compare the isotopic concentrations measured in a Post Irradiation Experiment and the results of the MC routine, examining the Takahama-3 assembly test case. From literature reports, roughly 35 nuclide species have been measured at different axial locations by destructive analysis following several radiochemical techniques. A sensitivity analysis to evaluate the impact of design features on the results was carried out investigating the cross-section libraries, the simulation time discretisation and the imposition of an axial time-varying temperature. During the process, systematic sources of geometry-related errors were analysed as well. Overall, the model showed good agreement with the experimental data under an acceptable error threshold. The sensitivity studies also showed how the prediction capability could be increased up to +6%, adopting a realistic temperature mesh for the fuel instead of a uniform temperature approach.","PeriodicalId":16756,"journal":{"name":"Journal of Nuclear Engineering and Radiation Science","volume":" 14","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Monte Carlo Fuel Assembly Model Validation Adopting Post Irradiation Experiment Dataset\",\"authors\":\"Lorenzo Loi, A. Cammi, S. Lorenzi, C. Introini\",\"doi\":\"10.1115/1.4064308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Within a hybrid energy system, it is fundamental to have accurate and reliable computational tools to predict the plants; behaviour under different operating conditions; compared to other energy sources, analysis methods for nuclear systems must provide detailed information on reactor criticality and fuel evolution. Thanks to the advancements in computational hardware, using three-dimensional codes to obtain a local description of the reactor core has now become feasible both for deterministic codes and for Monte Carlo (MC) codes. Those computational methods must be compared with experimental measurements to assess their reliability. For this reason, the 3D MC code SERPENT is currently being validated for Light Water Reactor (LWR) fuel cycle simulations. This work will compare the isotopic concentrations measured in a Post Irradiation Experiment and the results of the MC routine, examining the Takahama-3 assembly test case. From literature reports, roughly 35 nuclide species have been measured at different axial locations by destructive analysis following several radiochemical techniques. A sensitivity analysis to evaluate the impact of design features on the results was carried out investigating the cross-section libraries, the simulation time discretisation and the imposition of an axial time-varying temperature. During the process, systematic sources of geometry-related errors were analysed as well. Overall, the model showed good agreement with the experimental data under an acceptable error threshold. The sensitivity studies also showed how the prediction capability could be increased up to +6%, adopting a realistic temperature mesh for the fuel instead of a uniform temperature approach.\",\"PeriodicalId\":16756,\"journal\":{\"name\":\"Journal of Nuclear Engineering and Radiation Science\",\"volume\":\" 14\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nuclear Engineering and Radiation Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4064308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Engineering and Radiation Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4064308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
在混合能源系统中,最重要的是要有准确可靠的计算工具来预测发电厂在不同运行条件下的行为;与其他能源相比,核系统的分析方法必须提供反应堆临界状态和燃料演变的详细信息。由于计算硬件的进步,无论是确定性代码还是蒙特卡罗(MC)代码,使用三维代码获得反应堆堆芯的局部描述现已变得可行。这些计算方法必须与实验测量结果进行比较,以评估其可靠性。因此,三维 MC 代码 SERPENT 目前正在进行轻水反应堆(LWR)燃料循环模拟验证。这项工作将比较在辐照后实验中测得的同位素浓度和 MC 程序的结果,并对高滨-3 号装配测试案例进行研究。根据文献报告,通过采用多种放射化学技术进行破坏性分析,在不同轴向位置测量了大约 35 种核素。对横截面库、模拟时间离散化和轴向时变温度进行了敏感性分析,以评估设计特征对结果的影响。在此过程中,还分析了几何相关误差的系统来源。总体而言,在可接受的误差阈值范围内,模型与实验数据显示出良好的一致性。灵敏度研究还表明,如果采用现实的燃料温度网格而不是均匀温度方法,预测能力最多可提高 6%。
A Monte Carlo Fuel Assembly Model Validation Adopting Post Irradiation Experiment Dataset
Within a hybrid energy system, it is fundamental to have accurate and reliable computational tools to predict the plants; behaviour under different operating conditions; compared to other energy sources, analysis methods for nuclear systems must provide detailed information on reactor criticality and fuel evolution. Thanks to the advancements in computational hardware, using three-dimensional codes to obtain a local description of the reactor core has now become feasible both for deterministic codes and for Monte Carlo (MC) codes. Those computational methods must be compared with experimental measurements to assess their reliability. For this reason, the 3D MC code SERPENT is currently being validated for Light Water Reactor (LWR) fuel cycle simulations. This work will compare the isotopic concentrations measured in a Post Irradiation Experiment and the results of the MC routine, examining the Takahama-3 assembly test case. From literature reports, roughly 35 nuclide species have been measured at different axial locations by destructive analysis following several radiochemical techniques. A sensitivity analysis to evaluate the impact of design features on the results was carried out investigating the cross-section libraries, the simulation time discretisation and the imposition of an axial time-varying temperature. During the process, systematic sources of geometry-related errors were analysed as well. Overall, the model showed good agreement with the experimental data under an acceptable error threshold. The sensitivity studies also showed how the prediction capability could be increased up to +6%, adopting a realistic temperature mesh for the fuel instead of a uniform temperature approach.
期刊介绍:
The Journal of Nuclear Engineering and Radiation Science is ASME’s latest title within the energy sector. The publication is for specialists in the nuclear/power engineering areas of industry, academia, and government.