热红外自动亮度温度辐射计的设计与验证

Yanna Zhang, Yunxiang Zhang, Wei Wei
{"title":"热红外自动亮度温度辐射计的设计与验证","authors":"Yanna Zhang, Yunxiang Zhang, Wei Wei","doi":"10.1117/12.3008010","DOIUrl":null,"url":null,"abstract":"In order to meet the requirements of high precision automatic measurement of surface brightness temperature, which is used for in-orbit calibration and product verification of infrared remote sensor, the design and verification of field thermal infrared brightness temperature radiometer are studied. The difference and compensation method is used to obtain the radiance of the ground target. First, the thermopile detector is used to measure the target and the background respectively for difference, and then the standard platinum resistance is used to improve the measurement accuracy. The optical spectrum of 8~14 μm, 8.2~9.2 μm, 10.3~ 11.3 μm, 11.5~l2.5 μm is achieved by the optical spectrum and rotation of the filter wheel, and the photoelectric amplification and acquisition are realized by the high-precision pre-amplification and acquisition circuit. After the radiometer is developed, radiation calibration based on the surface source blackbody is carried out, and the temperature measurement is compared with the laboratory water blackbody. The deviation of measurement is less than 0.14K. The field thermal infrared bright temperature radiometer was compared with thermal infrared radiometer CE312 in the field, and the average deviation of the two devices was less than 0.12K, which verified the feasibility and rationality of the temperature measurement method.","PeriodicalId":298662,"journal":{"name":"Applied Optics and Photonics China","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and verification of thermal infrared automatic brightness temperature radiometer\",\"authors\":\"Yanna Zhang, Yunxiang Zhang, Wei Wei\",\"doi\":\"10.1117/12.3008010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to meet the requirements of high precision automatic measurement of surface brightness temperature, which is used for in-orbit calibration and product verification of infrared remote sensor, the design and verification of field thermal infrared brightness temperature radiometer are studied. The difference and compensation method is used to obtain the radiance of the ground target. First, the thermopile detector is used to measure the target and the background respectively for difference, and then the standard platinum resistance is used to improve the measurement accuracy. The optical spectrum of 8~14 μm, 8.2~9.2 μm, 10.3~ 11.3 μm, 11.5~l2.5 μm is achieved by the optical spectrum and rotation of the filter wheel, and the photoelectric amplification and acquisition are realized by the high-precision pre-amplification and acquisition circuit. After the radiometer is developed, radiation calibration based on the surface source blackbody is carried out, and the temperature measurement is compared with the laboratory water blackbody. The deviation of measurement is less than 0.14K. The field thermal infrared bright temperature radiometer was compared with thermal infrared radiometer CE312 in the field, and the average deviation of the two devices was less than 0.12K, which verified the feasibility and rationality of the temperature measurement method.\",\"PeriodicalId\":298662,\"journal\":{\"name\":\"Applied Optics and Photonics China\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Optics and Photonics China\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.3008010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Optics and Photonics China","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3008010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了满足高精度地表亮度温度自动测量的要求,用于红外遥感器的在轨校准和产品验证,研究了野外热红外亮度温度辐射计的设计与验证。采用差分补偿法获得地面目标的辐射度。首先使用热电堆探测器分别测量目标和背景进行差分,然后使用标准铂电阻提高测量精度。通过光学光谱和旋转滤光轮实现 8~14 μm、8.2~9.2 μm、10.3~11.3 μm、11.5~l2.5 μm,通过高精度预放大和采集电路实现光电放大和采集。辐射计研制成功后,根据面源黑体进行了辐射校准,并与实验室水黑体进行了温度测量对比。测量偏差小于 0.14K。现场热红外亮温辐射计与现场热红外辐射计 CE312 进行对比,两台设备的平均偏差小于 0.12K,验证了温度测量方法的可行性和合理性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and verification of thermal infrared automatic brightness temperature radiometer
In order to meet the requirements of high precision automatic measurement of surface brightness temperature, which is used for in-orbit calibration and product verification of infrared remote sensor, the design and verification of field thermal infrared brightness temperature radiometer are studied. The difference and compensation method is used to obtain the radiance of the ground target. First, the thermopile detector is used to measure the target and the background respectively for difference, and then the standard platinum resistance is used to improve the measurement accuracy. The optical spectrum of 8~14 μm, 8.2~9.2 μm, 10.3~ 11.3 μm, 11.5~l2.5 μm is achieved by the optical spectrum and rotation of the filter wheel, and the photoelectric amplification and acquisition are realized by the high-precision pre-amplification and acquisition circuit. After the radiometer is developed, radiation calibration based on the surface source blackbody is carried out, and the temperature measurement is compared with the laboratory water blackbody. The deviation of measurement is less than 0.14K. The field thermal infrared bright temperature radiometer was compared with thermal infrared radiometer CE312 in the field, and the average deviation of the two devices was less than 0.12K, which verified the feasibility and rationality of the temperature measurement method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Composition disorder in InAs/InAsSb superlattice by STM Optical true time delay technique with bidirectional consistency based on unidirectional optical amplifier Large curvature concave metallic mesh with high optical transmittance and strong electromagnetic interference shielding efficiency DP-OOK to QPSK conversion based on vector phase-sensitive amplification bridging core and access networks Real-time digitized RoF transceiver technology based on FPGA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1