Hye Jin Lee, Jun Ho Oh, Yong Koo Kang, Dai Woo Kim, Byeong Jae Son
{"title":"内镜下泪囊鼻腔造口术中采用锤凿和钻孔技术创建上骨膜的手术效果","authors":"Hye Jin Lee, Jun Ho Oh, Yong Koo Kang, Dai Woo Kim, Byeong Jae Son","doi":"10.3341/jkos.2023.64.12.1127","DOIUrl":null,"url":null,"abstract":"Purpose: We introduce a “cold steel” hammer-chisel technique for endoscopic dacryocystorhinostomy, then compare postoperative outcomes between this technique and a drill technique.Methods: This study included 191 patients (297 eyes) with nasolacrimal duct stenoses or obstructions who underwent endoscopic dacryocystorhinostomy using the hammer-chisel or drill technique. Surgical outcomes were compared via follow-up screening for epiphora and anatomical complications such as granuloma and fibrous membrane formation, canalicular obstruction, and synechiae.Results: Postoperative anatomical complications occurred in 29 eyes (18.6%) in the hammer-chisel group and 51 eyes (36.2%) in the drill group (p = 0.001). The anatomical failure rate was higher in the drill group [28 eyes (19.9%)] than in the hammer-chisel group [18 eyes (11.5%); p = 0.038]. Functional failure was observed in 13 eyes (8.3%) in the hammer-chisel group and 13 eyes (9.2%) in the drill group (p = 0.787). The mean operation time was significantly longer in the drill group (35.5 ± 10.4 minutes vs. 25.4 ± 9.1 minutes) (p < 0.001).Conclusions: During endoscopic dacryocystorhinostomy, osteotomy with a hammer-chisel is more successful and leads to fewer complications than osteotomy with a drill.","PeriodicalId":17341,"journal":{"name":"Journal of The Korean Ophthalmological Society","volume":"315 5","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surgical Outcomes of Hammer-Chisel and Drill Techniques to Create Superior Bony Ostium During Endoscopic Dacryocystorhinostomy\",\"authors\":\"Hye Jin Lee, Jun Ho Oh, Yong Koo Kang, Dai Woo Kim, Byeong Jae Son\",\"doi\":\"10.3341/jkos.2023.64.12.1127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: We introduce a “cold steel” hammer-chisel technique for endoscopic dacryocystorhinostomy, then compare postoperative outcomes between this technique and a drill technique.Methods: This study included 191 patients (297 eyes) with nasolacrimal duct stenoses or obstructions who underwent endoscopic dacryocystorhinostomy using the hammer-chisel or drill technique. Surgical outcomes were compared via follow-up screening for epiphora and anatomical complications such as granuloma and fibrous membrane formation, canalicular obstruction, and synechiae.Results: Postoperative anatomical complications occurred in 29 eyes (18.6%) in the hammer-chisel group and 51 eyes (36.2%) in the drill group (p = 0.001). The anatomical failure rate was higher in the drill group [28 eyes (19.9%)] than in the hammer-chisel group [18 eyes (11.5%); p = 0.038]. Functional failure was observed in 13 eyes (8.3%) in the hammer-chisel group and 13 eyes (9.2%) in the drill group (p = 0.787). The mean operation time was significantly longer in the drill group (35.5 ± 10.4 minutes vs. 25.4 ± 9.1 minutes) (p < 0.001).Conclusions: During endoscopic dacryocystorhinostomy, osteotomy with a hammer-chisel is more successful and leads to fewer complications than osteotomy with a drill.\",\"PeriodicalId\":17341,\"journal\":{\"name\":\"Journal of The Korean Ophthalmological Society\",\"volume\":\"315 5\",\"pages\":\"\"},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2023-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Korean Ophthalmological Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3341/jkos.2023.64.12.1127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/jkos.2023.64.12.1127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Surgical Outcomes of Hammer-Chisel and Drill Techniques to Create Superior Bony Ostium During Endoscopic Dacryocystorhinostomy
Purpose: We introduce a “cold steel” hammer-chisel technique for endoscopic dacryocystorhinostomy, then compare postoperative outcomes between this technique and a drill technique.Methods: This study included 191 patients (297 eyes) with nasolacrimal duct stenoses or obstructions who underwent endoscopic dacryocystorhinostomy using the hammer-chisel or drill technique. Surgical outcomes were compared via follow-up screening for epiphora and anatomical complications such as granuloma and fibrous membrane formation, canalicular obstruction, and synechiae.Results: Postoperative anatomical complications occurred in 29 eyes (18.6%) in the hammer-chisel group and 51 eyes (36.2%) in the drill group (p = 0.001). The anatomical failure rate was higher in the drill group [28 eyes (19.9%)] than in the hammer-chisel group [18 eyes (11.5%); p = 0.038]. Functional failure was observed in 13 eyes (8.3%) in the hammer-chisel group and 13 eyes (9.2%) in the drill group (p = 0.787). The mean operation time was significantly longer in the drill group (35.5 ± 10.4 minutes vs. 25.4 ± 9.1 minutes) (p < 0.001).Conclusions: During endoscopic dacryocystorhinostomy, osteotomy with a hammer-chisel is more successful and leads to fewer complications than osteotomy with a drill.