Muhammad Farooq , Muhammad Riaz ur Rehman , Patricia Vazquez , William Wijns , Atif Shahzad , Marcin J. Kraśny
{"title":"动态心血管模型的开源控制器","authors":"Muhammad Farooq , Muhammad Riaz ur Rehman , Patricia Vazquez , William Wijns , Atif Shahzad , Marcin J. Kraśny","doi":"10.1016/j.ohx.2023.e00500","DOIUrl":null,"url":null,"abstract":"<div><p>Cardiovascular pressure sensors require dedicated, reliable, and customisable performance testing equipment. Devices available on the market, such as pulsatile pumps and pulse multipliers, offer limited adaptability to the needs of pressure sensor testing or are highly complex tools designed for other purposes. Therefore, there is a strong need to provide an adaptable and versatile device for characterisation during prototype development, prior to animal model testing. Early development requires detailed characterisation of a sensor performance in a realistic environmental scenario. To address this need, we adapted an off-the-shelf pressure chamber with a custom Arduino-based controller to achieve a rapid change in pressure that simulates the pulsatile profile of human blood pressure. The system is a highly customisable tool, and we have experimentally shown that it works successfully in a wide range of pressures from 30 mmHg to 400 mmHg with a resolution of 2 mmHg. By adjusting the chamber volume using a water balloon, we achieved a cycle rate of up to 120 beats per minute. The device can be operated directly from the Arduino IDE or with a customised graphical user interface developed by our research group. The proposed system is intended to assist other researchers in the development of industrial and biomedical pressure sensors.</p></div>","PeriodicalId":37503,"journal":{"name":"HardwareX","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2023-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2468067223001074/pdfft?md5=3e38158cf6a2b9be99df9221ffc21b6c&pid=1-s2.0-S2468067223001074-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Open-source controller for dynamic cardiovascular models\",\"authors\":\"Muhammad Farooq , Muhammad Riaz ur Rehman , Patricia Vazquez , William Wijns , Atif Shahzad , Marcin J. Kraśny\",\"doi\":\"10.1016/j.ohx.2023.e00500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Cardiovascular pressure sensors require dedicated, reliable, and customisable performance testing equipment. Devices available on the market, such as pulsatile pumps and pulse multipliers, offer limited adaptability to the needs of pressure sensor testing or are highly complex tools designed for other purposes. Therefore, there is a strong need to provide an adaptable and versatile device for characterisation during prototype development, prior to animal model testing. Early development requires detailed characterisation of a sensor performance in a realistic environmental scenario. To address this need, we adapted an off-the-shelf pressure chamber with a custom Arduino-based controller to achieve a rapid change in pressure that simulates the pulsatile profile of human blood pressure. The system is a highly customisable tool, and we have experimentally shown that it works successfully in a wide range of pressures from 30 mmHg to 400 mmHg with a resolution of 2 mmHg. By adjusting the chamber volume using a water balloon, we achieved a cycle rate of up to 120 beats per minute. The device can be operated directly from the Arduino IDE or with a customised graphical user interface developed by our research group. The proposed system is intended to assist other researchers in the development of industrial and biomedical pressure sensors.</p></div>\",\"PeriodicalId\":37503,\"journal\":{\"name\":\"HardwareX\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2468067223001074/pdfft?md5=3e38158cf6a2b9be99df9221ffc21b6c&pid=1-s2.0-S2468067223001074-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HardwareX\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2468067223001074\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HardwareX","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468067223001074","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Open-source controller for dynamic cardiovascular models
Cardiovascular pressure sensors require dedicated, reliable, and customisable performance testing equipment. Devices available on the market, such as pulsatile pumps and pulse multipliers, offer limited adaptability to the needs of pressure sensor testing or are highly complex tools designed for other purposes. Therefore, there is a strong need to provide an adaptable and versatile device for characterisation during prototype development, prior to animal model testing. Early development requires detailed characterisation of a sensor performance in a realistic environmental scenario. To address this need, we adapted an off-the-shelf pressure chamber with a custom Arduino-based controller to achieve a rapid change in pressure that simulates the pulsatile profile of human blood pressure. The system is a highly customisable tool, and we have experimentally shown that it works successfully in a wide range of pressures from 30 mmHg to 400 mmHg with a resolution of 2 mmHg. By adjusting the chamber volume using a water balloon, we achieved a cycle rate of up to 120 beats per minute. The device can be operated directly from the Arduino IDE or with a customised graphical user interface developed by our research group. The proposed system is intended to assist other researchers in the development of industrial and biomedical pressure sensors.
HardwareXEngineering-Industrial and Manufacturing Engineering
CiteScore
4.10
自引率
18.20%
发文量
124
审稿时长
24 weeks
期刊介绍:
HardwareX is an open access journal established to promote free and open source designing, building and customizing of scientific infrastructure (hardware). HardwareX aims to recognize researchers for the time and effort in developing scientific infrastructure while providing end-users with sufficient information to replicate and validate the advances presented. HardwareX is open to input from all scientific, technological and medical disciplines. Scientific infrastructure will be interpreted in the broadest sense. Including hardware modifications to existing infrastructure, sensors and tools that perform measurements and other functions outside of the traditional lab setting (such as wearables, air/water quality sensors, and low cost alternatives to existing tools), and the creation of wholly new tools for either standard or novel laboratory tasks. Authors are encouraged to submit hardware developments that address all aspects of science, not only the final measurement, for example, enhancements in sample preparation and handling, user safety, and quality control. The use of distributed digital manufacturing strategies (e.g. 3-D printing) is encouraged. All designs must be submitted under an open hardware license.