假体周围关节感染的 PJI-TNM 分类。

IF 4.7 2区 医学 Q2 CELL & TISSUE ENGINEERING Bone & Joint Research Pub Date : 2024-01-05 DOI:10.1302/2046-3758.131.BJR-2023-0012.R2
Susanne Baertl, Markus Rupp, Maximilian Kerschbaum, Mario Morgenstern, Florian Baumann, Christian Pfeifer, Michael Worlicek, Daniel Popp, Derek F Amanatullah, Volker Alt
{"title":"假体周围关节感染的 PJI-TNM 分类。","authors":"Susanne Baertl, Markus Rupp, Maximilian Kerschbaum, Mario Morgenstern, Florian Baumann, Christian Pfeifer, Michael Worlicek, Daniel Popp, Derek F Amanatullah, Volker Alt","doi":"10.1302/2046-3758.131.BJR-2023-0012.R2","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>This study aimed to evaluate the clinical application of the PJI-TNM classification for periprosthetic joint infection (PJI) by determining intraobserver and interobserver reliability. To facilitate its use in clinical practice, an educational app was subsequently developed and evaluated.</p><p><strong>Methods: </strong>A total of ten orthopaedic surgeons classified 20 cases of PJI based on the PJI-TNM classification. Subsequently, the classification was re-evaluated using the PJI-TNM app. Classification accuracy was calculated separately for each subcategory (reinfection, tissue and implant condition, non-human cells, and morbidity of the patient). Fleiss' kappa and Cohen's kappa were calculated for interobserver and intraobserver reliability, respectively.</p><p><strong>Results: </strong>Overall, interobserver and intraobserver agreements were substantial across the 20 classified cases. Analyses for the variable 'reinfection' revealed an almost perfect interobserver and intraobserver agreement with a classification accuracy of 94.8%. The category 'tissue and implant conditions' showed moderate interobserver and substantial intraobserver reliability, while the classification accuracy was 70.8%. For 'non-human cells,' accuracy was 81.0% and interobserver agreement was moderate with an almost perfect intraobserver reliability. The classification accuracy of the variable 'morbidity of the patient' reached 73.5% with a moderate interobserver agreement, whereas the intraobserver agreement was substantial. The application of the app yielded comparable results across all subgroups.</p><p><strong>Conclusion: </strong>The PJI-TNM classification system captures the heterogeneity of PJI and can be applied with substantial inter- and intraobserver reliability. The PJI-TNM educational app aims to facilitate application in clinical practice. A major limitation was the correct assessment of the implant situation. To eliminate this, a re-evaluation according to intraoperative findings is strongly recommended.</p>","PeriodicalId":9074,"journal":{"name":"Bone & Joint Research","volume":"13 1","pages":"19-27"},"PeriodicalIF":4.7000,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10766470/pdf/","citationCount":"0","resultStr":"{\"title\":\"The PJI-TNM classification for periprosthetic joint infections.\",\"authors\":\"Susanne Baertl, Markus Rupp, Maximilian Kerschbaum, Mario Morgenstern, Florian Baumann, Christian Pfeifer, Michael Worlicek, Daniel Popp, Derek F Amanatullah, Volker Alt\",\"doi\":\"10.1302/2046-3758.131.BJR-2023-0012.R2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>This study aimed to evaluate the clinical application of the PJI-TNM classification for periprosthetic joint infection (PJI) by determining intraobserver and interobserver reliability. To facilitate its use in clinical practice, an educational app was subsequently developed and evaluated.</p><p><strong>Methods: </strong>A total of ten orthopaedic surgeons classified 20 cases of PJI based on the PJI-TNM classification. Subsequently, the classification was re-evaluated using the PJI-TNM app. Classification accuracy was calculated separately for each subcategory (reinfection, tissue and implant condition, non-human cells, and morbidity of the patient). Fleiss' kappa and Cohen's kappa were calculated for interobserver and intraobserver reliability, respectively.</p><p><strong>Results: </strong>Overall, interobserver and intraobserver agreements were substantial across the 20 classified cases. Analyses for the variable 'reinfection' revealed an almost perfect interobserver and intraobserver agreement with a classification accuracy of 94.8%. The category 'tissue and implant conditions' showed moderate interobserver and substantial intraobserver reliability, while the classification accuracy was 70.8%. For 'non-human cells,' accuracy was 81.0% and interobserver agreement was moderate with an almost perfect intraobserver reliability. The classification accuracy of the variable 'morbidity of the patient' reached 73.5% with a moderate interobserver agreement, whereas the intraobserver agreement was substantial. The application of the app yielded comparable results across all subgroups.</p><p><strong>Conclusion: </strong>The PJI-TNM classification system captures the heterogeneity of PJI and can be applied with substantial inter- and intraobserver reliability. The PJI-TNM educational app aims to facilitate application in clinical practice. A major limitation was the correct assessment of the implant situation. To eliminate this, a re-evaluation according to intraoperative findings is strongly recommended.</p>\",\"PeriodicalId\":9074,\"journal\":{\"name\":\"Bone & Joint Research\",\"volume\":\"13 1\",\"pages\":\"19-27\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10766470/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bone & Joint Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1302/2046-3758.131.BJR-2023-0012.R2\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CELL & TISSUE ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/2046-3758.131.BJR-2023-0012.R2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在通过确定观察者内部和观察者之间的可靠性,评估PJI-TNM分类在假体周围关节感染(PJI)中的临床应用。为便于在临床实践中使用,研究人员随后开发并评估了一款教育应用程序:方法:共有 10 名骨科医生根据 PJI-TNM 分类法对 20 例 PJI 病例进行了分类。随后,使用 PJI-TNM 应用程序对分类进行了重新评估。分别计算了每个子类别(再感染、组织和植入物状况、非人类细胞和患者发病率)的分类准确性。弗莱斯卡帕和科恩卡帕分别用于计算观察者间和观察者内的可靠性:总体而言,在 20 个分类病例中,观察者之间和观察者内部的一致性都很高。对变量 "再感染 "的分析表明,观察者间和观察者内的一致性几乎达到了完美的程度,分类准确率为 94.8%。在 "组织和植入物条件 "类别中,观察者间的可靠性和观察者内的可靠性均处于中等水平,分类准确率为 70.8%。非人类细胞 "的准确率为 81.0%,观察者之间的一致性为中等,观察者内部的可靠性几乎为完美。病人发病率 "变量的分类准确率为 73.5%,观察者之间的一致性为中等,而观察者内部的一致性则很高。结论:PJI-TNM 分级系统在所有亚组中的应用结果都具有可比性:结论:PJI-TNM 分类系统捕捉到了 PJI 的异质性,其应用在观察者之间和观察者内部的可靠性都很高。PJI-TNM教育应用程序旨在促进临床实践中的应用。一个主要限制因素是对植入情况的正确评估。为消除这一问题,强烈建议根据术中发现进行重新评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The PJI-TNM classification for periprosthetic joint infections.

Aims: This study aimed to evaluate the clinical application of the PJI-TNM classification for periprosthetic joint infection (PJI) by determining intraobserver and interobserver reliability. To facilitate its use in clinical practice, an educational app was subsequently developed and evaluated.

Methods: A total of ten orthopaedic surgeons classified 20 cases of PJI based on the PJI-TNM classification. Subsequently, the classification was re-evaluated using the PJI-TNM app. Classification accuracy was calculated separately for each subcategory (reinfection, tissue and implant condition, non-human cells, and morbidity of the patient). Fleiss' kappa and Cohen's kappa were calculated for interobserver and intraobserver reliability, respectively.

Results: Overall, interobserver and intraobserver agreements were substantial across the 20 classified cases. Analyses for the variable 'reinfection' revealed an almost perfect interobserver and intraobserver agreement with a classification accuracy of 94.8%. The category 'tissue and implant conditions' showed moderate interobserver and substantial intraobserver reliability, while the classification accuracy was 70.8%. For 'non-human cells,' accuracy was 81.0% and interobserver agreement was moderate with an almost perfect intraobserver reliability. The classification accuracy of the variable 'morbidity of the patient' reached 73.5% with a moderate interobserver agreement, whereas the intraobserver agreement was substantial. The application of the app yielded comparable results across all subgroups.

Conclusion: The PJI-TNM classification system captures the heterogeneity of PJI and can be applied with substantial inter- and intraobserver reliability. The PJI-TNM educational app aims to facilitate application in clinical practice. A major limitation was the correct assessment of the implant situation. To eliminate this, a re-evaluation according to intraoperative findings is strongly recommended.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bone & Joint Research
Bone & Joint Research CELL & TISSUE ENGINEERING-ORTHOPEDICS
CiteScore
7.40
自引率
23.90%
发文量
156
审稿时长
12 weeks
期刊介绍: The gold open access journal for the musculoskeletal sciences. Included in PubMed and available in PubMed Central.
期刊最新文献
Corrigendum. Correlation of cross-linking as measured by the trans-vinylene index and in vitro wear of polyethylene from various acetabular liner brands. Multidimensional characteristics are associated with pain severity in osteonecrosis of the femoral head. Inhibition of PA28γ expression can alleviate osteoarthritis by inhibiting endoplasmic reticulum stress and promoting STAT3 phosphorylation. Urgent focus on enhanced recovery after surgery of AIDS patients with limb fractures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1