Jian Yu, Renhui Shen, Le Zhou, Zelin Jia, Yulong Hao
{"title":"混合调制模式三电平 ANPC 逆变器中的低速换向电压冲击问题研究","authors":"Jian Yu, Renhui Shen, Le Zhou, Zelin Jia, Yulong Hao","doi":"10.3390/machines12010027","DOIUrl":null,"url":null,"abstract":"With the development of the photovoltaic industry; there will be an increasing demand for efficient, high-power density, and low-cost grid interface converters. Compared with two-level inverters, multilevel inverters have the following advantages: (1) lower device voltage ratings; (2) better output filtering spectrum; (3) lower electromagnetic interference (EMI) noise; and (4) higher switching speed capability. However, the complex switching circuit of the multilevel inverter will bring more parasitic inductance, resulting in severe switching overvoltage (ringing). Especially in order to reduce the cost of the inverter, using the long-loop modulation mode, the commutation loop will introduce more parasitic inductance, which will make the overvoltage more serious. Consider that commonly used overvoltage absorption schemes are effective only for overvoltage or suppression of oscillations. Therefore, a new overvoltage absorption circuit is proposed in this paper, which can not only alleviate the overvoltage and ringing phenomena but also suppress the effect of voltage jumps during low-frequency switching on high-frequency input voltage. This overvoltage absorption circuit is characterized by low overvoltage, fast ringing damping, and minimum capacitance. Experiments and simulations are conducted to verify the effectiveness of this overvoltage absorption circuit using a three-level ANPC inverter as a prototype. The results show that the proposed overvoltage absorption circuit can significantly reduce the overvoltage level, shorten the oscillation time, and reduce the voltage difference between the upper and lower DC bus capacitors.","PeriodicalId":48519,"journal":{"name":"Machines","volume":" 6","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2023-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of a Low-Speed Commutation Voltage Shock Problem in Three-Level ANPC Inverter with Hybrid Modulation Mode\",\"authors\":\"Jian Yu, Renhui Shen, Le Zhou, Zelin Jia, Yulong Hao\",\"doi\":\"10.3390/machines12010027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the development of the photovoltaic industry; there will be an increasing demand for efficient, high-power density, and low-cost grid interface converters. Compared with two-level inverters, multilevel inverters have the following advantages: (1) lower device voltage ratings; (2) better output filtering spectrum; (3) lower electromagnetic interference (EMI) noise; and (4) higher switching speed capability. However, the complex switching circuit of the multilevel inverter will bring more parasitic inductance, resulting in severe switching overvoltage (ringing). Especially in order to reduce the cost of the inverter, using the long-loop modulation mode, the commutation loop will introduce more parasitic inductance, which will make the overvoltage more serious. Consider that commonly used overvoltage absorption schemes are effective only for overvoltage or suppression of oscillations. Therefore, a new overvoltage absorption circuit is proposed in this paper, which can not only alleviate the overvoltage and ringing phenomena but also suppress the effect of voltage jumps during low-frequency switching on high-frequency input voltage. This overvoltage absorption circuit is characterized by low overvoltage, fast ringing damping, and minimum capacitance. Experiments and simulations are conducted to verify the effectiveness of this overvoltage absorption circuit using a three-level ANPC inverter as a prototype. The results show that the proposed overvoltage absorption circuit can significantly reduce the overvoltage level, shorten the oscillation time, and reduce the voltage difference between the upper and lower DC bus capacitors.\",\"PeriodicalId\":48519,\"journal\":{\"name\":\"Machines\",\"volume\":\" 6\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Machines\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/machines12010027\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Machines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/machines12010027","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Investigation of a Low-Speed Commutation Voltage Shock Problem in Three-Level ANPC Inverter with Hybrid Modulation Mode
With the development of the photovoltaic industry; there will be an increasing demand for efficient, high-power density, and low-cost grid interface converters. Compared with two-level inverters, multilevel inverters have the following advantages: (1) lower device voltage ratings; (2) better output filtering spectrum; (3) lower electromagnetic interference (EMI) noise; and (4) higher switching speed capability. However, the complex switching circuit of the multilevel inverter will bring more parasitic inductance, resulting in severe switching overvoltage (ringing). Especially in order to reduce the cost of the inverter, using the long-loop modulation mode, the commutation loop will introduce more parasitic inductance, which will make the overvoltage more serious. Consider that commonly used overvoltage absorption schemes are effective only for overvoltage or suppression of oscillations. Therefore, a new overvoltage absorption circuit is proposed in this paper, which can not only alleviate the overvoltage and ringing phenomena but also suppress the effect of voltage jumps during low-frequency switching on high-frequency input voltage. This overvoltage absorption circuit is characterized by low overvoltage, fast ringing damping, and minimum capacitance. Experiments and simulations are conducted to verify the effectiveness of this overvoltage absorption circuit using a three-level ANPC inverter as a prototype. The results show that the proposed overvoltage absorption circuit can significantly reduce the overvoltage level, shorten the oscillation time, and reduce the voltage difference between the upper and lower DC bus capacitors.
期刊介绍:
Machines (ISSN 2075-1702) is an international, peer-reviewed journal on machinery and engineering. It publishes research articles, reviews, short communications and letters. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. Full experimental and/or methodical details must be provided. There are, in addition, unique features of this journal: *manuscripts regarding research proposals and research ideas will be particularly welcomed *electronic files or software regarding the full details of the calculation and experimental procedure - if unable to be published in a normal way - can be deposited as supplementary material Subject Areas: applications of automation, systems and control engineering, electronic engineering, mechanical engineering, computer engineering, mechatronics, robotics, industrial design, human-machine-interfaces, mechanical systems, machines and related components, machine vision, history of technology and industrial revolution, turbo machinery, machine diagnostics and prognostics (condition monitoring), machine design.