评估磷酸或 Er: YAG 激光对 980 激光辅助漂白后正畸托槽与珐琅质表面的剪切粘接强度的影响:一项体外研究

IF 1.4 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of lasers in medical sciences Pub Date : 2023-12-13 DOI:10.34172/jlms.2023.62
Mohammad Oladzad, N. Chiniforush, R. Bahrami, A. Mirhashemi
{"title":"评估磷酸或 Er: YAG 激光对 980 激光辅助漂白后正畸托槽与珐琅质表面的剪切粘接强度的影响:一项体外研究","authors":"Mohammad Oladzad, N. Chiniforush, R. Bahrami, A. Mirhashemi","doi":"10.34172/jlms.2023.62","DOIUrl":null,"url":null,"abstract":"Introduction: The residual oxygen remained on tooth surface after bleaching may interfere with adhesion of brackets to enamel surface. This study aimed to evaluate the influence of phosphoric acid and Er: YAG laser as an etching technique on the shear bond strength (SBS) of orthodontic brackets to enamel surfaces after 980-laser-assisted bleaching. Method: A total of 84 human premolars were recruited in the present study. Samples were divided into 6 groups including conventional bleaching with conventional etching, conventional bleaching with Er: YAG laser etching, laser-assisted bleaching with conventional etching, and Laser-assisted bleaching with Er: YAG laser etching, without bleaching with traditional etching, and without bleaching+Er: YAG laser etching. Following thermocycling, the debonding of brackets was conducted using a universal testing machine. Scanning electron microscope (SEM) microscope evaluation and adhesive remnant index (ARI) scores were assessed. The comparison of SBS values between groups was carried out by means of a one-way analysis of variance, followed by post-hoc tests. Results: The non-bleaching with conventional etching group showed the highest SBS mean value (23.45±5.16 MPa), whereas the conventional bleaching with conventional etching group represented the lowest SBS mean value (8.8±3.83 MPa). In all groups, the most common type of failure was classified as either score 1 or score 2. No significant difference was observed in terms of SBS mean between the groups (P=0.165); however, the average SBS of bleached teeth was significantly lower, compared to the non-bleached group (P=0.000). Honeycomb structure and porosity were observed following Er: YAG laser etching on the tooth surface. Conclusion: Increased bond strength of brackets was observed in bleached teeth following Er: YAG laser etching. Therefore, if necessary, bond the brackets on the same day of bleaching will be done, the application of Er:YAG laser as etching technique will can be recommended.","PeriodicalId":16224,"journal":{"name":"Journal of lasers in medical sciences","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Effect of Phosphoric Acid or Er: YAG Laser on the Shear Bond Strength of Orthodontic Brackets to Enamel Surfaces Followed by 980-Laser Assisted Bleaching: An In Vitro Study\",\"authors\":\"Mohammad Oladzad, N. Chiniforush, R. Bahrami, A. Mirhashemi\",\"doi\":\"10.34172/jlms.2023.62\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: The residual oxygen remained on tooth surface after bleaching may interfere with adhesion of brackets to enamel surface. This study aimed to evaluate the influence of phosphoric acid and Er: YAG laser as an etching technique on the shear bond strength (SBS) of orthodontic brackets to enamel surfaces after 980-laser-assisted bleaching. Method: A total of 84 human premolars were recruited in the present study. Samples were divided into 6 groups including conventional bleaching with conventional etching, conventional bleaching with Er: YAG laser etching, laser-assisted bleaching with conventional etching, and Laser-assisted bleaching with Er: YAG laser etching, without bleaching with traditional etching, and without bleaching+Er: YAG laser etching. Following thermocycling, the debonding of brackets was conducted using a universal testing machine. Scanning electron microscope (SEM) microscope evaluation and adhesive remnant index (ARI) scores were assessed. The comparison of SBS values between groups was carried out by means of a one-way analysis of variance, followed by post-hoc tests. Results: The non-bleaching with conventional etching group showed the highest SBS mean value (23.45±5.16 MPa), whereas the conventional bleaching with conventional etching group represented the lowest SBS mean value (8.8±3.83 MPa). In all groups, the most common type of failure was classified as either score 1 or score 2. No significant difference was observed in terms of SBS mean between the groups (P=0.165); however, the average SBS of bleached teeth was significantly lower, compared to the non-bleached group (P=0.000). Honeycomb structure and porosity were observed following Er: YAG laser etching on the tooth surface. Conclusion: Increased bond strength of brackets was observed in bleached teeth following Er: YAG laser etching. Therefore, if necessary, bond the brackets on the same day of bleaching will be done, the application of Er:YAG laser as etching technique will can be recommended.\",\"PeriodicalId\":16224,\"journal\":{\"name\":\"Journal of lasers in medical sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of lasers in medical sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/jlms.2023.62\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of lasers in medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/jlms.2023.62","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

简介漂白后残留在牙齿表面的氧气可能会干扰托槽与珐琅质表面的粘合。本研究旨在评估磷酸和 Er: YAG 激光作为蚀刻技术对 980 激光辅助漂白后正畸托槽与珐琅质表面的剪切粘结强度(SBS)的影响。方法:本研究共采集了 84 颗人类前臼齿。样本分为 6 组,包括传统漂白与传统蚀刻组、传统漂白与 Er: YAG 激光蚀刻组、激光辅助漂白与传统蚀刻组、激光辅助漂白与 Er: YAG 激光蚀刻组、无漂白与传统蚀刻组、无漂白+Er: YAG 激光蚀刻组。热循环后,使用万能试验机进行托架脱粘试验。扫描电子显微镜(SEM)显微镜评估和粘合剂残留指数(ARI)评分。通过单因素方差分析对各组的 SBS 值进行比较,然后进行事后检验。结果显示非漂白与传统蚀刻组的 SBS 平均值最高(23.45±5.16 MPa),而传统漂白与传统蚀刻组的 SBS 平均值最低(8.8±3.83 MPa)。在所有组别中,最常见的故障类型分为 1 级和 2 级。各组之间的 SBS 平均值无明显差异(P=0.165);但漂白牙齿的平均 SBS 值明显低于非漂白组(P=0.000)。在对牙齿表面进行 Er: YAG 激光蚀刻后,可观察到蜂窝状结构和多孔性。结论经 Er: YAG 激光蚀刻后,漂白牙的托槽粘接强度有所提高。因此,如果有必要在漂白当天粘接托槽,建议使用 Er:YAG 激光作为蚀刻技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the Effect of Phosphoric Acid or Er: YAG Laser on the Shear Bond Strength of Orthodontic Brackets to Enamel Surfaces Followed by 980-Laser Assisted Bleaching: An In Vitro Study
Introduction: The residual oxygen remained on tooth surface after bleaching may interfere with adhesion of brackets to enamel surface. This study aimed to evaluate the influence of phosphoric acid and Er: YAG laser as an etching technique on the shear bond strength (SBS) of orthodontic brackets to enamel surfaces after 980-laser-assisted bleaching. Method: A total of 84 human premolars were recruited in the present study. Samples were divided into 6 groups including conventional bleaching with conventional etching, conventional bleaching with Er: YAG laser etching, laser-assisted bleaching with conventional etching, and Laser-assisted bleaching with Er: YAG laser etching, without bleaching with traditional etching, and without bleaching+Er: YAG laser etching. Following thermocycling, the debonding of brackets was conducted using a universal testing machine. Scanning electron microscope (SEM) microscope evaluation and adhesive remnant index (ARI) scores were assessed. The comparison of SBS values between groups was carried out by means of a one-way analysis of variance, followed by post-hoc tests. Results: The non-bleaching with conventional etching group showed the highest SBS mean value (23.45±5.16 MPa), whereas the conventional bleaching with conventional etching group represented the lowest SBS mean value (8.8±3.83 MPa). In all groups, the most common type of failure was classified as either score 1 or score 2. No significant difference was observed in terms of SBS mean between the groups (P=0.165); however, the average SBS of bleached teeth was significantly lower, compared to the non-bleached group (P=0.000). Honeycomb structure and porosity were observed following Er: YAG laser etching on the tooth surface. Conclusion: Increased bond strength of brackets was observed in bleached teeth following Er: YAG laser etching. Therefore, if necessary, bond the brackets on the same day of bleaching will be done, the application of Er:YAG laser as etching technique will can be recommended.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of lasers in medical sciences
Journal of lasers in medical sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
13.30%
发文量
24
期刊介绍: The "Journal of Lasers in Medical Sciences " is a scientific quarterly publication of the Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences. This journal received a scientific and research rank from the national medical publication committee. This Journal accepts original papers, review articles, case reports, brief reports, case series, photo assays, letters to the editor, and commentaries in the field of laser, or light in any fields of medicine such as the following medical specialties: -Dermatology -General and Vascular Surgery -Oncology -Cardiology -Dentistry -Urology -Rehabilitation -Ophthalmology -Otorhinolaryngology -Gynecology & Obstetrics -Internal Medicine -Orthopedics -Neurosurgery -Radiology -Pain Medicine (Algology) -Basic Sciences (Stem cell, Cellular and Molecular application and physic)
期刊最新文献
Effects of Photobiomodulation Using Low-Power Diode Laser Therapy and Nano-bone on Mandibular Bone Regeneration in Rats. Comparison of the Effects of Gluma Gel, Sensodyne Repair and Protect Toothpaste, and an 810 nm Low Power Diode Laser on the Closure of Dentinal Tubules: An In Vitro Study. Photobiomodulation Improves Histological Parameters of Testis and Spermatogenesis in Adult Mice Exposed to Scrotal Hyperthermia in the Prepubertal Phase. Enhanced Therapeutic Efficacy of Gold Nanoparticle-Enhanced Laser Therapy for Oral Cancer: A Promising Photothermal Approach. Molecular Mechanism Analysis of Intensive Light-Induced Retinal Damages.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1