PT PLN(Persero)Payakumbuh 客户服务实施单位(UP3)20 KV 配电网络的电磁辐射暴露分析

Rinda Andhita Regia, Resti Ayu Lestari, Nidham Faadhil As'ad, Randy Zulkarnain
{"title":"PT PLN(Persero)Payakumbuh 客户服务实施单位(UP3)20 KV 配电网络的电磁辐射暴露分析","authors":"Rinda Andhita Regia, Resti Ayu Lestari, Nidham Faadhil As'ad, Randy Zulkarnain","doi":"10.14710/jil.21.4.755-765","DOIUrl":null,"url":null,"abstract":"Salah satu pekerjaan yang akan terdampak radiasi elektromagnetik ke pekerja perusahaan milik BUMN yaitu PT PLN (Persero). Kegiatan PT PLN (Persero) dalam menjalankan penyediaan tenaga listrik seperti kegiatan pembangkit, penyaluran dan distribusi. Tujuan penelitian ini adalah mengidentifikasi risiko paparan radiasi elektromagnetik pada lingkungan kerja bagian distribusi di PT PLN (Persero) UP3 Payakumbuh. Pengukuran radiasi medan magnet menggunakan alat EMF Field Tester (EMF-823). Pengukuran radiasi elektromagnetik pada lingkungan kerja PT PLN (Persero) UP3 Payakumbuh bagian jaringan distribusi seperti pekerjaan di area Tranformator (Trafo Step Down), Jaringan Tegangan Menengah (JTM), dan Load Break Switch (LBS). Pengukuran dilakukan di 26 lokasi terdiri dari 11 lokasi pekerjaan trafo, 3 lokasi pekerjaan JTM, dan 12 lokasi pekerjaan LBS. Lokasi penelitian dilaksanakan di 26 lokasi. Pengukuran dilakukan pada saat pekerjaan berlangsung dan setelah pekerjaan selesai dilaksanakan. Titik pengukuran pada pekerja dilakukan pada sumber, jarak 1 meter, 2 meter, dan 3 meter dari sumber radiasi, dan pada masyarakat yang berada dekat dengan sumber sebanyak 2 titik. Hasil penelitian menunjukkan nilai radiasi medan magnet yang terpapar ke pekerja pada saat pekerjaan untuk pekerjaan trafo berkisar antara 0,00-0,05 µT, pekerjaan tiang JTM yaitu 0,00 µT, dan untuk pekerjaan LBS yaitu 0,00-0,12 µT. Nilai radiasi medan magnet yang terpapar ke masyarakat yaitu 0,00 µT. Hal ini menandakan bahwa nilai radiasi medan magnet pada pekerja dan masyarakat masih memenuhi baku mutu Peraturan Menteri Kesehatan Republik Indonesia No. 70 tahun 2016 dan International Commission and Non-Ionizing Radiation Protection (ICNIRP) yang artinya masih aman dan tidak berisiko menimbulkan gangguan kesehatan pekerja dan masyarakat.Kata kunci: Medan magnet, PT. PLN UP3 Payakumbuh, Radiasi elektromagnetik ABSTRACTOne of the jobs that will be affected by electromagnetic radiation is PT PLN (Persero). PT PLN (Persero)'s activities in carrying out electricity such as generating, distribution, and distribution activities. This study aimed to identify the risk of exposure to electromagnetic radiation in the distribution division work environment at PT PLN (Persero) UP3 Payakumbuh. Measurement of magnetic field radiation using the EMF Field Tester (EMF-823). Measurement of electromagnetic radiation in the work environment of PT PLN (Persero) UP3 Payakumbuh in the distribution network section, such as work in the Transformer (Step Down) area, Medium Voltage Network (JTM), and Load Break Switch (LBS). This research was conducted at 26 locations consisting of 11 transformer workplaces, 3 JTM workplaces, and 12 LBS workplaces. The research location was carried out in 26 areas. It is made during the work in progress and after the work is completed. Measurement points for workers are carried out at the source, a distance of 1 meter, 2 meters, and 3 meters from the radiation source, and 2 points for the public. The results showed that the radiation value of the magnetic field exposed to workers at the time of work for transformer work ranged from 0.00-0.05 µT, JTM pole work was 0.00 µT, and for LBS work, it was 0.00-0.12 µT. The radiation value of the magnetic field exposed to the public is 0.00 µT. It indicates that the value of magnetic field radiation on workers and the public still meets the quality standards of the Regulation of the Minister of Health of the Republic of Indonesia No. 70 of 2016 and the International Commission and Non-Ionizing Radiation Protection (ICNIRP). So it is still safe and does not risk causing health problems for workers and the public.Keywords: Magnetic field, PT. PLN UP3 Payakumbuh, Electromagentic radiation","PeriodicalId":53112,"journal":{"name":"Jurnal Ilmu Lingkungan","volume":"40 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisis Paparan Radiasi Elektromagnetik di Jaringan Distribusi 20 KV PT PLN (Persero) Unit Pelaksana Pelayanan Pelanggan (UP3) Payakumbuh\",\"authors\":\"Rinda Andhita Regia, Resti Ayu Lestari, Nidham Faadhil As'ad, Randy Zulkarnain\",\"doi\":\"10.14710/jil.21.4.755-765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Salah satu pekerjaan yang akan terdampak radiasi elektromagnetik ke pekerja perusahaan milik BUMN yaitu PT PLN (Persero). Kegiatan PT PLN (Persero) dalam menjalankan penyediaan tenaga listrik seperti kegiatan pembangkit, penyaluran dan distribusi. Tujuan penelitian ini adalah mengidentifikasi risiko paparan radiasi elektromagnetik pada lingkungan kerja bagian distribusi di PT PLN (Persero) UP3 Payakumbuh. Pengukuran radiasi medan magnet menggunakan alat EMF Field Tester (EMF-823). Pengukuran radiasi elektromagnetik pada lingkungan kerja PT PLN (Persero) UP3 Payakumbuh bagian jaringan distribusi seperti pekerjaan di area Tranformator (Trafo Step Down), Jaringan Tegangan Menengah (JTM), dan Load Break Switch (LBS). Pengukuran dilakukan di 26 lokasi terdiri dari 11 lokasi pekerjaan trafo, 3 lokasi pekerjaan JTM, dan 12 lokasi pekerjaan LBS. Lokasi penelitian dilaksanakan di 26 lokasi. Pengukuran dilakukan pada saat pekerjaan berlangsung dan setelah pekerjaan selesai dilaksanakan. Titik pengukuran pada pekerja dilakukan pada sumber, jarak 1 meter, 2 meter, dan 3 meter dari sumber radiasi, dan pada masyarakat yang berada dekat dengan sumber sebanyak 2 titik. Hasil penelitian menunjukkan nilai radiasi medan magnet yang terpapar ke pekerja pada saat pekerjaan untuk pekerjaan trafo berkisar antara 0,00-0,05 µT, pekerjaan tiang JTM yaitu 0,00 µT, dan untuk pekerjaan LBS yaitu 0,00-0,12 µT. Nilai radiasi medan magnet yang terpapar ke masyarakat yaitu 0,00 µT. Hal ini menandakan bahwa nilai radiasi medan magnet pada pekerja dan masyarakat masih memenuhi baku mutu Peraturan Menteri Kesehatan Republik Indonesia No. 70 tahun 2016 dan International Commission and Non-Ionizing Radiation Protection (ICNIRP) yang artinya masih aman dan tidak berisiko menimbulkan gangguan kesehatan pekerja dan masyarakat.Kata kunci: Medan magnet, PT. PLN UP3 Payakumbuh, Radiasi elektromagnetik ABSTRACTOne of the jobs that will be affected by electromagnetic radiation is PT PLN (Persero). PT PLN (Persero)'s activities in carrying out electricity such as generating, distribution, and distribution activities. This study aimed to identify the risk of exposure to electromagnetic radiation in the distribution division work environment at PT PLN (Persero) UP3 Payakumbuh. Measurement of magnetic field radiation using the EMF Field Tester (EMF-823). Measurement of electromagnetic radiation in the work environment of PT PLN (Persero) UP3 Payakumbuh in the distribution network section, such as work in the Transformer (Step Down) area, Medium Voltage Network (JTM), and Load Break Switch (LBS). This research was conducted at 26 locations consisting of 11 transformer workplaces, 3 JTM workplaces, and 12 LBS workplaces. The research location was carried out in 26 areas. It is made during the work in progress and after the work is completed. Measurement points for workers are carried out at the source, a distance of 1 meter, 2 meters, and 3 meters from the radiation source, and 2 points for the public. The results showed that the radiation value of the magnetic field exposed to workers at the time of work for transformer work ranged from 0.00-0.05 µT, JTM pole work was 0.00 µT, and for LBS work, it was 0.00-0.12 µT. The radiation value of the magnetic field exposed to the public is 0.00 µT. It indicates that the value of magnetic field radiation on workers and the public still meets the quality standards of the Regulation of the Minister of Health of the Republic of Indonesia No. 70 of 2016 and the International Commission and Non-Ionizing Radiation Protection (ICNIRP). So it is still safe and does not risk causing health problems for workers and the public.Keywords: Magnetic field, PT. PLN UP3 Payakumbuh, Electromagentic radiation\",\"PeriodicalId\":53112,\"journal\":{\"name\":\"Jurnal Ilmu Lingkungan\",\"volume\":\"40 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Ilmu Lingkungan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14710/jil.21.4.755-765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Ilmu Lingkungan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/jil.21.4.755-765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

PT PLN(Persero)是受电磁辐射影响的国有企业员工工作岗位之一。PT PLN(Persero)的活动是提供电力,如发电、配电和分配活动。本研究旨在确定 PT PLN (Persero) UP3 Payakumbuh 配电部门工作环境中的电磁辐射暴露风险。使用电磁场测试仪(EMF-823)测量磁场辐射。测量PT PLN (Persero) UP3 Payakumbuh配电网络部门工作环境中的电磁辐射,如变压器区域(降压变压器)、中压网络(JTM)和负载断路开关(LBS)的工作环境。在 26 个地点进行了测量,包括 11 个变压器工作地点、3 个 JTM 工作地点和 12 个 LBS 工作地点。研究地点在 26 个地点进行。测量在工作期间和工作结束后进行。对工人的测量点分别在辐射源处、距离辐射源 1 米、2 米和 3 米的地方进行,在靠近辐射源的社区进行了多达 2 个点的测量。结果显示,工人在变压器工作时受到的磁场辐射值为 0.00-0.05 µT,JTM 电杆工作时为 0.00 µT,LBS 工作时为 0.00-0.12 µT。社区暴露的磁场辐射值为 0.00 µT。这表明工人和社区受到的磁场辐射值仍然符合印度尼西亚共和国卫生部长 2016 年第 70 号条例和国际非电离辐射防护委员会(ICNIRP)的质量标准,这意味着它仍然是安全的,不会对工人和社区造成健康问题:磁场,PT PLN UP3 Payakumbuh,电磁辐射 ABSTRACTO其中一个会受到电磁辐射影响的工作是PT PLN(Persero)。PT PLN(Persero)从事发电、配电和分销等电力活动。本研究旨在确定 PT PLN (Persero) UP3 Payakumbuh 配电部工作环境中暴露于电磁辐射的风险。使用电磁场测试仪(EMF-823)测量磁场辐射。测量PT PLN (Persero) UP3 Payakumbuh配电网络部门工作环境中的电磁辐射,如变压器(降压)区域、中压网络(JTM)和负载断路开关(LBS)的工作环境。这项研究在 26 个地点进行,包括 11 个变压器工作场所、3 个 JTM 工作场所和 12 个 LBS 工作场所。研究地点分布在 26 个区域。在工作进行中和工作结束后进行。工人的测量点在辐射源处、距离辐射源 1 米、2 米和 3 米处进行,公众的测量点为 2 个。结果显示,变压器工作时,工人暴露在磁场中的辐射值为 0.00-0.05 µT,JTM 电杆工作时为 0.00 µT,LBS 工作时为 0.00-0.12 µT。公众受到的磁场辐射值为 0.00 µT。这表明工人和公众受到的磁场辐射值仍然符合印度尼西亚共和国卫生部长 2016 年第 70 号条例和国际非电离辐射防护委员会(ICNIRP)的质量标准。因此,它仍然是安全的,不会对工人和公众造成健康问题:磁场 PT PLN UP3 Payakumbuh 电离辐射
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analisis Paparan Radiasi Elektromagnetik di Jaringan Distribusi 20 KV PT PLN (Persero) Unit Pelaksana Pelayanan Pelanggan (UP3) Payakumbuh
Salah satu pekerjaan yang akan terdampak radiasi elektromagnetik ke pekerja perusahaan milik BUMN yaitu PT PLN (Persero). Kegiatan PT PLN (Persero) dalam menjalankan penyediaan tenaga listrik seperti kegiatan pembangkit, penyaluran dan distribusi. Tujuan penelitian ini adalah mengidentifikasi risiko paparan radiasi elektromagnetik pada lingkungan kerja bagian distribusi di PT PLN (Persero) UP3 Payakumbuh. Pengukuran radiasi medan magnet menggunakan alat EMF Field Tester (EMF-823). Pengukuran radiasi elektromagnetik pada lingkungan kerja PT PLN (Persero) UP3 Payakumbuh bagian jaringan distribusi seperti pekerjaan di area Tranformator (Trafo Step Down), Jaringan Tegangan Menengah (JTM), dan Load Break Switch (LBS). Pengukuran dilakukan di 26 lokasi terdiri dari 11 lokasi pekerjaan trafo, 3 lokasi pekerjaan JTM, dan 12 lokasi pekerjaan LBS. Lokasi penelitian dilaksanakan di 26 lokasi. Pengukuran dilakukan pada saat pekerjaan berlangsung dan setelah pekerjaan selesai dilaksanakan. Titik pengukuran pada pekerja dilakukan pada sumber, jarak 1 meter, 2 meter, dan 3 meter dari sumber radiasi, dan pada masyarakat yang berada dekat dengan sumber sebanyak 2 titik. Hasil penelitian menunjukkan nilai radiasi medan magnet yang terpapar ke pekerja pada saat pekerjaan untuk pekerjaan trafo berkisar antara 0,00-0,05 µT, pekerjaan tiang JTM yaitu 0,00 µT, dan untuk pekerjaan LBS yaitu 0,00-0,12 µT. Nilai radiasi medan magnet yang terpapar ke masyarakat yaitu 0,00 µT. Hal ini menandakan bahwa nilai radiasi medan magnet pada pekerja dan masyarakat masih memenuhi baku mutu Peraturan Menteri Kesehatan Republik Indonesia No. 70 tahun 2016 dan International Commission and Non-Ionizing Radiation Protection (ICNIRP) yang artinya masih aman dan tidak berisiko menimbulkan gangguan kesehatan pekerja dan masyarakat.Kata kunci: Medan magnet, PT. PLN UP3 Payakumbuh, Radiasi elektromagnetik ABSTRACTOne of the jobs that will be affected by electromagnetic radiation is PT PLN (Persero). PT PLN (Persero)'s activities in carrying out electricity such as generating, distribution, and distribution activities. This study aimed to identify the risk of exposure to electromagnetic radiation in the distribution division work environment at PT PLN (Persero) UP3 Payakumbuh. Measurement of magnetic field radiation using the EMF Field Tester (EMF-823). Measurement of electromagnetic radiation in the work environment of PT PLN (Persero) UP3 Payakumbuh in the distribution network section, such as work in the Transformer (Step Down) area, Medium Voltage Network (JTM), and Load Break Switch (LBS). This research was conducted at 26 locations consisting of 11 transformer workplaces, 3 JTM workplaces, and 12 LBS workplaces. The research location was carried out in 26 areas. It is made during the work in progress and after the work is completed. Measurement points for workers are carried out at the source, a distance of 1 meter, 2 meters, and 3 meters from the radiation source, and 2 points for the public. The results showed that the radiation value of the magnetic field exposed to workers at the time of work for transformer work ranged from 0.00-0.05 µT, JTM pole work was 0.00 µT, and for LBS work, it was 0.00-0.12 µT. The radiation value of the magnetic field exposed to the public is 0.00 µT. It indicates that the value of magnetic field radiation on workers and the public still meets the quality standards of the Regulation of the Minister of Health of the Republic of Indonesia No. 70 of 2016 and the International Commission and Non-Ionizing Radiation Protection (ICNIRP). So it is still safe and does not risk causing health problems for workers and the public.Keywords: Magnetic field, PT. PLN UP3 Payakumbuh, Electromagentic radiation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
48
审稿时长
12 weeks
期刊最新文献
Pengendalian Pencemaran Air dengan API Separator Pada Air Limbah Produksi Kilang Ekstraksi Indeks Saprobik di Kawasan Mangrove Bedono, Kecamatan Sayung, Kabupaten Demak, Jawa Tengah Peran Stakeholder dalam Kajian Lingkungan Hidup Strategis Rencana Detail Tata Ruang Kawasan Perkotaan Manokwari Analisis Tingkat Erosi Hutan Jati di Kawasan Hutan dengan Tujuan Khusus (KHDTK) Cemoro Modang, Kabupaten Blora, Provinsi Jawa Tengah Jaringan Pengelolaan Sampah Rumah Tangga sebagai Bentuk Transisi Ekonomi Sirkular di Kota Surabaya
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1