Jiahao Chang, Chaoyang Zhu, Yuanpeng Song, Zhentao Wang
{"title":"具有网格结构的快速响应时间气体电离室探测器。","authors":"Jiahao Chang, Chaoyang Zhu, Yuanpeng Song, Zhentao Wang","doi":"10.3233/XST-230219","DOIUrl":null,"url":null,"abstract":"<p><p>The time response characteristic of the detector is crucial in radiation imaging systems. Unfortunately, existing parallel plate ionization chamber detectors have a slow response time, which leads to blurry radiation images. To enhance imaging quality, the electrode structure of the detector must be modified to reduce the response time. This paper proposes a gas detector with a grid structure that has a fast response time. In this study, the detector electrostatic field was calculated using COMSOL, while Garfield++ was utilized to simulate the detector's output signal. To validate the accuracy of simulation results, the experimental ionization chamber was tested on the experimental platform. The results revealed that the average electric field intensity in the induced region of the grid detector was increased by at least 33%. The detector response time was reduced to 27% -38% of that of the parallel plate detector, while the sensitivity of the detector was only reduced by 10%. Therefore, incorporating a grid structure within the parallel plate detector can significantly improve the time response characteristics of the gas detector, providing an insight for future detector enhancements.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A fast response time gas ionization chamber detector with a grid structure.\",\"authors\":\"Jiahao Chang, Chaoyang Zhu, Yuanpeng Song, Zhentao Wang\",\"doi\":\"10.3233/XST-230219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The time response characteristic of the detector is crucial in radiation imaging systems. Unfortunately, existing parallel plate ionization chamber detectors have a slow response time, which leads to blurry radiation images. To enhance imaging quality, the electrode structure of the detector must be modified to reduce the response time. This paper proposes a gas detector with a grid structure that has a fast response time. In this study, the detector electrostatic field was calculated using COMSOL, while Garfield++ was utilized to simulate the detector's output signal. To validate the accuracy of simulation results, the experimental ionization chamber was tested on the experimental platform. The results revealed that the average electric field intensity in the induced region of the grid detector was increased by at least 33%. The detector response time was reduced to 27% -38% of that of the parallel plate detector, while the sensitivity of the detector was only reduced by 10%. Therefore, incorporating a grid structure within the parallel plate detector can significantly improve the time response characteristics of the gas detector, providing an insight for future detector enhancements.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/XST-230219\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/XST-230219","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
A fast response time gas ionization chamber detector with a grid structure.
The time response characteristic of the detector is crucial in radiation imaging systems. Unfortunately, existing parallel plate ionization chamber detectors have a slow response time, which leads to blurry radiation images. To enhance imaging quality, the electrode structure of the detector must be modified to reduce the response time. This paper proposes a gas detector with a grid structure that has a fast response time. In this study, the detector electrostatic field was calculated using COMSOL, while Garfield++ was utilized to simulate the detector's output signal. To validate the accuracy of simulation results, the experimental ionization chamber was tested on the experimental platform. The results revealed that the average electric field intensity in the induced region of the grid detector was increased by at least 33%. The detector response time was reduced to 27% -38% of that of the parallel plate detector, while the sensitivity of the detector was only reduced by 10%. Therefore, incorporating a grid structure within the parallel plate detector can significantly improve the time response characteristics of the gas detector, providing an insight for future detector enhancements.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.