Miriam Hernández-Jiménez , Isabel Revilla , Ana M. Vivar-Quintana , Justyna Grabska , Krzysztof B. Beć , Christian W. Huck
{"title":"根据品种鉴别伊比利亚火腿的台式和便携式光谱设备的性能","authors":"Miriam Hernández-Jiménez , Isabel Revilla , Ana M. Vivar-Quintana , Justyna Grabska , Krzysztof B. Beć , Christian W. Huck","doi":"10.1016/j.crfs.2024.100675","DOIUrl":null,"url":null,"abstract":"<div><p>Iberian ham is a highly appreciated product and according to Spanish legislation different labels identify different products depending on the genetic purity. Consequently, “100% Iberian” ham from purebred Iberian animals is more expensive than “Iberian” ham from Iberian x Duroc crosses. The hypothesis of this study was that to avoid labelling fraud it is possible to distinguish the breed (Iberian or Iberian x Duroc) of acorn-fed pigs of Iberian ham without any prior preparation of the sample by using spectroscopy that is a rapid and reliable technology. Moreover, portable devices which can be used <em>in situ</em> could provide similar results to those of benchtop equipment. Therefore, the spectra of the 60 samples (24 samples of 100% Iberian ham and 36 samples of Iberian x Duroc crossbreed ham) were recorded only for the fat, only for the muscle, or for the whole slice with two benchtop near-infrared (NIR) spectrometers (Büchi NIRFlex N-500 and Foss NIRSystem 5000) and five portable spectrometers including four portable NIR devices (VIAVI MicroNIR 1700 ES, TellSpec Enterprise Sensor, Thermo Fischer Scientific microPHAZIR, and Consumer Physics SCiO Sensor), and one RAMAN device (BRAVO handheld). The results showed that, in general, the whole slice recording produced the best results for classification purposes. The SCiO device showed the highest percentages of correctly classified samples (97% in calibration and 92% in validation) followed by TellSpec (100% and 81%). The SCiO sensor also showed the highest percentages of success when the analyses were performed only on lean meat (97% in calibration and 83% in validation) followed by microPHAZIR (84% and 81%), while in the case of the fat tissue. Raman technology showed the best discrimination capacity (96% and 78%) followed by microPHAZIR (89% and 81%). Therefore, spectroscopy has proved to be a suitable technology for discriminating ham samples according to breed purity; portable devices have been shown to give even better results than benchtop spectrometers.</p></div>","PeriodicalId":10939,"journal":{"name":"Current Research in Food Science","volume":"8 ","pages":"Article 100675"},"PeriodicalIF":6.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2665927124000017/pdfft?md5=96eae69bb1e90510d5ca531d96a93995&pid=1-s2.0-S2665927124000017-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Performance of benchtop and portable spectroscopy equipment for discriminating Iberian ham according to breed\",\"authors\":\"Miriam Hernández-Jiménez , Isabel Revilla , Ana M. Vivar-Quintana , Justyna Grabska , Krzysztof B. Beć , Christian W. Huck\",\"doi\":\"10.1016/j.crfs.2024.100675\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Iberian ham is a highly appreciated product and according to Spanish legislation different labels identify different products depending on the genetic purity. Consequently, “100% Iberian” ham from purebred Iberian animals is more expensive than “Iberian” ham from Iberian x Duroc crosses. The hypothesis of this study was that to avoid labelling fraud it is possible to distinguish the breed (Iberian or Iberian x Duroc) of acorn-fed pigs of Iberian ham without any prior preparation of the sample by using spectroscopy that is a rapid and reliable technology. Moreover, portable devices which can be used <em>in situ</em> could provide similar results to those of benchtop equipment. Therefore, the spectra of the 60 samples (24 samples of 100% Iberian ham and 36 samples of Iberian x Duroc crossbreed ham) were recorded only for the fat, only for the muscle, or for the whole slice with two benchtop near-infrared (NIR) spectrometers (Büchi NIRFlex N-500 and Foss NIRSystem 5000) and five portable spectrometers including four portable NIR devices (VIAVI MicroNIR 1700 ES, TellSpec Enterprise Sensor, Thermo Fischer Scientific microPHAZIR, and Consumer Physics SCiO Sensor), and one RAMAN device (BRAVO handheld). The results showed that, in general, the whole slice recording produced the best results for classification purposes. The SCiO device showed the highest percentages of correctly classified samples (97% in calibration and 92% in validation) followed by TellSpec (100% and 81%). The SCiO sensor also showed the highest percentages of success when the analyses were performed only on lean meat (97% in calibration and 83% in validation) followed by microPHAZIR (84% and 81%), while in the case of the fat tissue. Raman technology showed the best discrimination capacity (96% and 78%) followed by microPHAZIR (89% and 81%). Therefore, spectroscopy has proved to be a suitable technology for discriminating ham samples according to breed purity; portable devices have been shown to give even better results than benchtop spectrometers.</p></div>\",\"PeriodicalId\":10939,\"journal\":{\"name\":\"Current Research in Food Science\",\"volume\":\"8 \",\"pages\":\"Article 100675\"},\"PeriodicalIF\":6.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2665927124000017/pdfft?md5=96eae69bb1e90510d5ca531d96a93995&pid=1-s2.0-S2665927124000017-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Research in Food Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2665927124000017\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Research in Food Science","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665927124000017","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
Performance of benchtop and portable spectroscopy equipment for discriminating Iberian ham according to breed
Iberian ham is a highly appreciated product and according to Spanish legislation different labels identify different products depending on the genetic purity. Consequently, “100% Iberian” ham from purebred Iberian animals is more expensive than “Iberian” ham from Iberian x Duroc crosses. The hypothesis of this study was that to avoid labelling fraud it is possible to distinguish the breed (Iberian or Iberian x Duroc) of acorn-fed pigs of Iberian ham without any prior preparation of the sample by using spectroscopy that is a rapid and reliable technology. Moreover, portable devices which can be used in situ could provide similar results to those of benchtop equipment. Therefore, the spectra of the 60 samples (24 samples of 100% Iberian ham and 36 samples of Iberian x Duroc crossbreed ham) were recorded only for the fat, only for the muscle, or for the whole slice with two benchtop near-infrared (NIR) spectrometers (Büchi NIRFlex N-500 and Foss NIRSystem 5000) and five portable spectrometers including four portable NIR devices (VIAVI MicroNIR 1700 ES, TellSpec Enterprise Sensor, Thermo Fischer Scientific microPHAZIR, and Consumer Physics SCiO Sensor), and one RAMAN device (BRAVO handheld). The results showed that, in general, the whole slice recording produced the best results for classification purposes. The SCiO device showed the highest percentages of correctly classified samples (97% in calibration and 92% in validation) followed by TellSpec (100% and 81%). The SCiO sensor also showed the highest percentages of success when the analyses were performed only on lean meat (97% in calibration and 83% in validation) followed by microPHAZIR (84% and 81%), while in the case of the fat tissue. Raman technology showed the best discrimination capacity (96% and 78%) followed by microPHAZIR (89% and 81%). Therefore, spectroscopy has proved to be a suitable technology for discriminating ham samples according to breed purity; portable devices have been shown to give even better results than benchtop spectrometers.
期刊介绍:
Current Research in Food Science is an international peer-reviewed journal dedicated to advancing the breadth of knowledge in the field of food science. It serves as a platform for publishing original research articles and short communications that encompass a wide array of topics, including food chemistry, physics, microbiology, nutrition, nutraceuticals, process and package engineering, materials science, food sustainability, and food security. By covering these diverse areas, the journal aims to provide a comprehensive source of the latest scientific findings and technological advancements that are shaping the future of the food industry. The journal's scope is designed to address the multidisciplinary nature of food science, reflecting its commitment to promoting innovation and ensuring the safety and quality of the food supply.