新型自消毒液在不可逆水胶体印模材料中的功效评估--一项实验研究。

Sunantha Selvaraj, Alarmelu, Dorairaj Jayachandran, Shanmuga Priya
{"title":"新型自消毒液在不可逆水胶体印模材料中的功效评估--一项实验研究。","authors":"Sunantha Selvaraj, Alarmelu, Dorairaj Jayachandran, Shanmuga Priya","doi":"10.4103/ijdr.ijdr_73_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Irreversible hydrocolloid materials are widely used for both diagnostic and definitive impression procedures. Impressions can be disinfected by immersion or spraying in any compatible disinfectant. Disinfectants should not adversely affect the dimensional stability of the impression and physical properties of impression material and subsequent dental cast.</p><p><strong>Objective: </strong>The study aims to evaluate the efficacy of a hypochlorous disinfectant solution mixed with irreversible hydrocolloid on setting time, antibacterial efficacy, and dimensional stability.</p><p><strong>Methodology: </strong>Three groups were made with one control group and three alginate impression was made for each participants in the maxillary arch with 24-hours intervals between one another using the same brand of commercially available chromatic alginate. The working and setting time were noted. Bacterial swabs were collected using a dry sterile cotton swab in the mid palatal region. Dental casts were made using type III gypsum.</p><p><strong>Result: </strong>The working and setting time had significant differences whereas the dimension among the cast has no significant difference. Microbial growth analysis had distinct differences among the groups.</p><p><strong>Conclusion: </strong>The self disinfection method using a pioneer solution of hypochlorous HOCl (100 ppm) to mix the alginate impression material rather than the water with the same powder-liquid ratio prescribed by the manufacturer had the same dimensional stability with improved antimicrobial action.</p>","PeriodicalId":13311,"journal":{"name":"Indian Journal of Dental Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Efficacy of Novel Self Disinfectant Solution in Irreversible Hydrocolloid Impression Material - An Experimental Study.\",\"authors\":\"Sunantha Selvaraj, Alarmelu, Dorairaj Jayachandran, Shanmuga Priya\",\"doi\":\"10.4103/ijdr.ijdr_73_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Irreversible hydrocolloid materials are widely used for both diagnostic and definitive impression procedures. Impressions can be disinfected by immersion or spraying in any compatible disinfectant. Disinfectants should not adversely affect the dimensional stability of the impression and physical properties of impression material and subsequent dental cast.</p><p><strong>Objective: </strong>The study aims to evaluate the efficacy of a hypochlorous disinfectant solution mixed with irreversible hydrocolloid on setting time, antibacterial efficacy, and dimensional stability.</p><p><strong>Methodology: </strong>Three groups were made with one control group and three alginate impression was made for each participants in the maxillary arch with 24-hours intervals between one another using the same brand of commercially available chromatic alginate. The working and setting time were noted. Bacterial swabs were collected using a dry sterile cotton swab in the mid palatal region. Dental casts were made using type III gypsum.</p><p><strong>Result: </strong>The working and setting time had significant differences whereas the dimension among the cast has no significant difference. Microbial growth analysis had distinct differences among the groups.</p><p><strong>Conclusion: </strong>The self disinfection method using a pioneer solution of hypochlorous HOCl (100 ppm) to mix the alginate impression material rather than the water with the same powder-liquid ratio prescribed by the manufacturer had the same dimensional stability with improved antimicrobial action.</p>\",\"PeriodicalId\":13311,\"journal\":{\"name\":\"Indian Journal of Dental Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ijdr.ijdr_73_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijdr.ijdr_73_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:不可逆水胶体材料广泛用于诊断性和确定性印模程序。可通过浸泡或喷洒任何兼容的消毒剂对印模进行消毒。消毒剂不应对印模的尺寸稳定性、印模材料的物理性质以及随后的牙科铸模造成不利影响:本研究旨在评估次氯酸消毒剂溶液与不可逆水胶体混合后对凝固时间、抗菌效果和尺寸稳定性的影响:使用同一品牌的市售色素藻酸盐,为上颌牙弓的每位参与者制作三个藻酸盐印模,每个印模之间间隔 24 小时。记录工作时间和凝固时间。用干的无菌棉签在腭中部区域采集细菌拭子。使用 III 型石膏制作牙模:结果:石膏的工作时间和凝固时间有显著差异,而石膏的尺寸没有显著差异。微生物生长分析在各组之间存在明显差异:结论:使用次氯酸 HOCl 先驱溶液(100 ppm)混合海藻酸盐印模材料,而不是制造商规定的相同粉液比例的水进行自我消毒的方法,具有相同的尺寸稳定性和更好的抗菌作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the Efficacy of Novel Self Disinfectant Solution in Irreversible Hydrocolloid Impression Material - An Experimental Study.

Background: Irreversible hydrocolloid materials are widely used for both diagnostic and definitive impression procedures. Impressions can be disinfected by immersion or spraying in any compatible disinfectant. Disinfectants should not adversely affect the dimensional stability of the impression and physical properties of impression material and subsequent dental cast.

Objective: The study aims to evaluate the efficacy of a hypochlorous disinfectant solution mixed with irreversible hydrocolloid on setting time, antibacterial efficacy, and dimensional stability.

Methodology: Three groups were made with one control group and three alginate impression was made for each participants in the maxillary arch with 24-hours intervals between one another using the same brand of commercially available chromatic alginate. The working and setting time were noted. Bacterial swabs were collected using a dry sterile cotton swab in the mid palatal region. Dental casts were made using type III gypsum.

Result: The working and setting time had significant differences whereas the dimension among the cast has no significant difference. Microbial growth analysis had distinct differences among the groups.

Conclusion: The self disinfection method using a pioneer solution of hypochlorous HOCl (100 ppm) to mix the alginate impression material rather than the water with the same powder-liquid ratio prescribed by the manufacturer had the same dimensional stability with improved antimicrobial action.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Dental Research
Indian Journal of Dental Research Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
80
审稿时长
38 weeks
期刊介绍: Indian Journal of Dental Research (IJDR) is the official publication of the Indian Society for Dental Research (ISDR), India section of the International Association for Dental Research (IADR), published quarterly. IJDR publishes scientific papers on well designed and controlled original research involving orodental sciences. Papers may also include reports on unusual and interesting case presentations and invited review papers on significant topics.
期刊最新文献
Effect of Bisoctrizole on Ultraviolet (UV) Absorption Properties of Silicone and Effect on Surface Roughness - An In Vitro Study. Effect of Densah Burs on Primary and Secondary Stability of Immediately Loaded Implants in Addition to Crestal Bone Loss and Gingival Probing Depth - An Evaluative Study. Effect of Fluoride-releasing Resin Cement on the Development of White Spot Lesions Around Orthodontic Brackets - A Retrospective Study. Effect of Reduced-Step Polishing Systems on Color Stability of Nanocomposites Submitted to Thermocycling Staining with Common Beverages - An In Vitro Study. Evaluation of Stresses Generated with Two Different Self-Ligating Orthodontic Bracket Systems - A Finite Element Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1