比较 CBCT 和模型扫描仪对牙科模型的扫描。体外成像精度研究

IF 1.8 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Orthodontics Pub Date : 2024-01-12 DOI:10.1016/j.ortho.2023.100840
Ioannis A. Tsolakis , Aliki Rontogianni , Apostolos I. Tsolakis , Moschos A. Papadopoulos
{"title":"比较 CBCT 和模型扫描仪对牙科模型的扫描。体外成像精度研究","authors":"Ioannis A. Tsolakis ,&nbsp;Aliki Rontogianni ,&nbsp;Apostolos I. Tsolakis ,&nbsp;Moschos A. Papadopoulos","doi":"10.1016/j.ortho.2023.100840","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p><span>The aim of this study is to compare the accuracy of cone beam computed tomography (CBCT) for </span>dental model scanning to the accuracy of model scanners.</p></div><div><h3>Methods</h3><p>Subjects from private practice were collected and scanned according to specific selection criteria. A total of 10 STL files were produced and used as reference files. They were printed with a three-dimensional (3D) printer and then scanned with CBCT and model scanner. For trueness evaluation, all models were scanned once with both equipments. Each file derived from each scan was compared with the corresponding reference model file. For the precision measurements, the physical model from the first master reference model file was scanned 10 times with each equipment and compared with the reference STL file. A reverse engineering software was used for all 3D best-fit comparisons.</p></div><div><h3>Results</h3><p>With regard to the measurement of trueness of each method, the calculated mean root mean square (RMS) value was 0.06<!--> <!-->±<!--> <!-->0.01<!--> <!-->mm for the CBCT, and 0.15<!--> <!-->±<!--> <!-->0.02<!--> <!-->mm for the model scanner. There was a significant difference between the two methods (<em>P</em> <!-->&lt;<!--> <!-->0.01). For the evaluation of precision of each scanner, the mean RMS value was 0.0056<!--> <!-->±<!--> <!-->0.001<!--> <!-->mm for the CBCT, and 0.153<!--> <!-->±<!--> <!-->0.002<!--> <!-->mm for model scanner. There was a significant difference between the two methods (<em>P</em> <!-->&lt;<!--> <!-->0.01).</p></div><div><h3>Conclusions</h3><p>Cone Beam Computed Tomography seems to be an accurate method for scanning dental models. CBCT performs better than model scanners to scan dental models in terms of trueness and precision.</p></div>","PeriodicalId":45449,"journal":{"name":"International Orthodontics","volume":"22 1","pages":"Article 100840"},"PeriodicalIF":1.8000,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparing CBCT to model scanner for dental model scanning. An in vitro imaging accuracy study\",\"authors\":\"Ioannis A. Tsolakis ,&nbsp;Aliki Rontogianni ,&nbsp;Apostolos I. Tsolakis ,&nbsp;Moschos A. Papadopoulos\",\"doi\":\"10.1016/j.ortho.2023.100840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p><span>The aim of this study is to compare the accuracy of cone beam computed tomography (CBCT) for </span>dental model scanning to the accuracy of model scanners.</p></div><div><h3>Methods</h3><p>Subjects from private practice were collected and scanned according to specific selection criteria. A total of 10 STL files were produced and used as reference files. They were printed with a three-dimensional (3D) printer and then scanned with CBCT and model scanner. For trueness evaluation, all models were scanned once with both equipments. Each file derived from each scan was compared with the corresponding reference model file. For the precision measurements, the physical model from the first master reference model file was scanned 10 times with each equipment and compared with the reference STL file. A reverse engineering software was used for all 3D best-fit comparisons.</p></div><div><h3>Results</h3><p>With regard to the measurement of trueness of each method, the calculated mean root mean square (RMS) value was 0.06<!--> <!-->±<!--> <!-->0.01<!--> <!-->mm for the CBCT, and 0.15<!--> <!-->±<!--> <!-->0.02<!--> <!-->mm for the model scanner. There was a significant difference between the two methods (<em>P</em> <!-->&lt;<!--> <!-->0.01). For the evaluation of precision of each scanner, the mean RMS value was 0.0056<!--> <!-->±<!--> <!-->0.001<!--> <!-->mm for the CBCT, and 0.153<!--> <!-->±<!--> <!-->0.002<!--> <!-->mm for model scanner. There was a significant difference between the two methods (<em>P</em> <!-->&lt;<!--> <!-->0.01).</p></div><div><h3>Conclusions</h3><p>Cone Beam Computed Tomography seems to be an accurate method for scanning dental models. CBCT performs better than model scanners to scan dental models in terms of trueness and precision.</p></div>\",\"PeriodicalId\":45449,\"journal\":{\"name\":\"International Orthodontics\",\"volume\":\"22 1\",\"pages\":\"Article 100840\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-01-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Orthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1761722723001195\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1761722723001195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在比较锥形束计算机断层扫描(CBCT)用于牙科模型扫描的准确性和模型扫描仪的准确性:方法: 收集来自私人诊所的受试者,并按照特定的选择标准进行扫描。共制作了 10 个 STL 文件作为参考文件。用三维(3D)打印机打印这些文件,然后用 CBCT 和模型扫描仪进行扫描。为了进行真实性评估,所有模型都用这两种设备扫描了一次。将每次扫描得到的每个文件与相应的参考模型文件进行比较。在精度测量方面,第一个主参考模型文件中的物理模型用每种设备扫描 10 次,并与参考 STL 文件进行比较。所有三维最佳拟合比较均使用逆向工程软件:关于每种方法的真实度测量,CBCT 的计算均方根(RMS)值为 0.06±0.01mm,而模型扫描仪的计算均方根(RMS)值为 0.15±0.02mm。两种方法之间存在明显差异(PC 结论:锥形束计算机断层扫描似乎是一种扫描牙科模型的精确方法。就真实度和精确度而言,锥形束计算机断层扫描比模型扫描仪扫描牙科模型的效果更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparing CBCT to model scanner for dental model scanning. An in vitro imaging accuracy study

Objective

The aim of this study is to compare the accuracy of cone beam computed tomography (CBCT) for dental model scanning to the accuracy of model scanners.

Methods

Subjects from private practice were collected and scanned according to specific selection criteria. A total of 10 STL files were produced and used as reference files. They were printed with a three-dimensional (3D) printer and then scanned with CBCT and model scanner. For trueness evaluation, all models were scanned once with both equipments. Each file derived from each scan was compared with the corresponding reference model file. For the precision measurements, the physical model from the first master reference model file was scanned 10 times with each equipment and compared with the reference STL file. A reverse engineering software was used for all 3D best-fit comparisons.

Results

With regard to the measurement of trueness of each method, the calculated mean root mean square (RMS) value was 0.06 ± 0.01 mm for the CBCT, and 0.15 ± 0.02 mm for the model scanner. There was a significant difference between the two methods (P < 0.01). For the evaluation of precision of each scanner, the mean RMS value was 0.0056 ± 0.001 mm for the CBCT, and 0.153 ± 0.002 mm for model scanner. There was a significant difference between the two methods (P < 0.01).

Conclusions

Cone Beam Computed Tomography seems to be an accurate method for scanning dental models. CBCT performs better than model scanners to scan dental models in terms of trueness and precision.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Orthodontics
International Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.50
自引率
13.30%
发文量
71
审稿时长
26 days
期刊介绍: Une revue de référence dans le domaine de orthodontie et des disciplines frontières Your reference in dentofacial orthopedics International Orthodontics adresse aux orthodontistes, aux dentistes, aux stomatologistes, aux chirurgiens maxillo-faciaux et aux plasticiens de la face, ainsi quà leurs assistant(e)s. International Orthodontics is addressed to orthodontists, dentists, stomatologists, maxillofacial surgeons and facial plastic surgeons, as well as their assistants.
期刊最新文献
Severe anterior open bite in a Class II hyperdivergent adult patient: A case report of clear aligner orthodontic camouflage treatment Editorial Board Contents Effect of post-curing parameters and material thickness on the color stability of 3D-printed dental resins: An in vitro study Acknowledgement to our Reviewers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1