设计具有机械宏观拓扑结构和微生物晶格的 3D 打印医疗植入物:用于胫骨高位截骨术的新型楔形垫片和生物力学研究

IF 6.8 3区 医学 Q1 ENGINEERING, BIOMEDICAL International Journal of Bioprinting Pub Date : 2024-01-10 DOI:10.36922/ijb.1584
Hsuan-Wen Wang, Chih-Hwa Chen, Kuan-Hao Chen, Yu-Hui Zeng, Chun-Li Lin
{"title":"设计具有机械宏观拓扑结构和微生物晶格的 3D 打印医疗植入物:用于胫骨高位截骨术的新型楔形垫片和生物力学研究","authors":"Hsuan-Wen Wang, Chih-Hwa Chen, Kuan-Hao Chen, Yu-Hui Zeng, Chun-Li Lin","doi":"10.36922/ijb.1584","DOIUrl":null,"url":null,"abstract":"Metal three-dimensional (3D) printing has become an important manufacturing process in medical implant development. Nevertheless, the metal 3D-printed implant needs to be considered with structural optimization to reduce the stress-shielding effects and to be incorporated with a lattice design to generate better bone ingrowth environment. This study combines topology optimization (TO) and lattice design to acquire an optimal wedge-shaped spacer (OWS) for high tibial osteotomy (HTO) fixation. The OWS was manufactured using titanium alloy 3D printing to conduct biomechanical fatigue testing for mechanical performance validation. A solid wedge-shaped spacer (SWS) with three embedded screws was designed using the HTO model. An OWS was obtained under physiological loads through finite element (FE) analysis and TO. A deformed YM lattice with a porosity of 60% and pore size of 700 μm was filled at the OWS posterior region. The HTO mechanical performance was simulated for SWS, OWS, and commercial T-shaped plate (TP) fixations using FE analysis. The displacement/fracture patterns under OWS and TP fixations were verified using fatigue testing. The manufacturing errors for all 3D-printed OWS features were found to be less than 1%. The FE results revealed that the OWS fixation demonstrated reductions of 56.46%, 11.98%, and 64.31% in displacement, stress in the implant and bone, respectively, compared to the TP fixation. The fatigue test indicated that the OWS fixation exhibited smaller displacement for the HTO, as well as a higher load capacity, minor bone fracture collapse, and a greater number of cycles than the TP system. This study concluded that medical implants can be designed by integrating macro TO and microlattice design to provide enough mechanical strength and an environment for bone ingrowth after surgery. Both FE analysis and biomechanical fatigue tests confirmed that OWS mechanical performance with lattice design was more stable than the HTO TP fixations.","PeriodicalId":48522,"journal":{"name":"International Journal of Bioprinting","volume":"41 12","pages":""},"PeriodicalIF":6.8000,"publicationDate":"2024-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Designing a 3D-printed medical implant with mechanically macrostructural topology and microbionic lattices: A novel wedge-shaped spacer for high tibial osteotomy and biomechanical study\",\"authors\":\"Hsuan-Wen Wang, Chih-Hwa Chen, Kuan-Hao Chen, Yu-Hui Zeng, Chun-Li Lin\",\"doi\":\"10.36922/ijb.1584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Metal three-dimensional (3D) printing has become an important manufacturing process in medical implant development. Nevertheless, the metal 3D-printed implant needs to be considered with structural optimization to reduce the stress-shielding effects and to be incorporated with a lattice design to generate better bone ingrowth environment. This study combines topology optimization (TO) and lattice design to acquire an optimal wedge-shaped spacer (OWS) for high tibial osteotomy (HTO) fixation. The OWS was manufactured using titanium alloy 3D printing to conduct biomechanical fatigue testing for mechanical performance validation. A solid wedge-shaped spacer (SWS) with three embedded screws was designed using the HTO model. An OWS was obtained under physiological loads through finite element (FE) analysis and TO. A deformed YM lattice with a porosity of 60% and pore size of 700 μm was filled at the OWS posterior region. The HTO mechanical performance was simulated for SWS, OWS, and commercial T-shaped plate (TP) fixations using FE analysis. The displacement/fracture patterns under OWS and TP fixations were verified using fatigue testing. The manufacturing errors for all 3D-printed OWS features were found to be less than 1%. The FE results revealed that the OWS fixation demonstrated reductions of 56.46%, 11.98%, and 64.31% in displacement, stress in the implant and bone, respectively, compared to the TP fixation. The fatigue test indicated that the OWS fixation exhibited smaller displacement for the HTO, as well as a higher load capacity, minor bone fracture collapse, and a greater number of cycles than the TP system. This study concluded that medical implants can be designed by integrating macro TO and microlattice design to provide enough mechanical strength and an environment for bone ingrowth after surgery. Both FE analysis and biomechanical fatigue tests confirmed that OWS mechanical performance with lattice design was more stable than the HTO TP fixations.\",\"PeriodicalId\":48522,\"journal\":{\"name\":\"International Journal of Bioprinting\",\"volume\":\"41 12\",\"pages\":\"\"},\"PeriodicalIF\":6.8000,\"publicationDate\":\"2024-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Bioprinting\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.36922/ijb.1584\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Bioprinting","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.36922/ijb.1584","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

金属三维(3D)打印已成为医疗植入物开发的重要制造工艺。然而,金属三维打印植入物需要考虑结构优化,以减少应力屏蔽效应,并与晶格设计相结合,以产生更好的骨生长环境。本研究将拓扑优化(TO)和晶格设计相结合,以获得用于高胫骨截骨术(HTO)固定的最佳楔形垫片(OWS)。OWS 采用钛合金 3D 打印技术制造,并进行了生物力学疲劳测试,以验证其机械性能。利用 HTO 模型设计了带有三个嵌入螺钉的实心楔形垫片(SWS)。通过有限元(FE)分析和 TO,获得了生理负荷下的 OWS。在 OWS 后部区域填充了孔隙率为 60%、孔径为 700 μm 的变形 YM 晶格。利用有限元分析模拟了 SWS、OWS 和商用 T 型钢板(TP)固定的 HTO 机械性能。通过疲劳测试验证了 OWS 和 TP 固定下的位移/断裂模式。所有 3D 打印 OWS 特征的制造误差均小于 1%。有限元分析结果显示,与 TP 固定相比,OWS 固定的位移、植入体和骨的应力分别减少了 56.46%、11.98% 和 64.31%。疲劳测试表明,与 TP 系统相比,OWS 固定器的 HTO 位移更小,承载能力更高,骨骨折塌陷更小,循环次数更多。这项研究得出结论,医疗植入物可以通过整合宏观 TO 和微格设计来提供足够的机械强度和术后骨生长环境。有限元分析和生物力学疲劳测试均证实,采用晶格设计的 OWS 机械性能比 HTO TP 固定装置更稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Designing a 3D-printed medical implant with mechanically macrostructural topology and microbionic lattices: A novel wedge-shaped spacer for high tibial osteotomy and biomechanical study
Metal three-dimensional (3D) printing has become an important manufacturing process in medical implant development. Nevertheless, the metal 3D-printed implant needs to be considered with structural optimization to reduce the stress-shielding effects and to be incorporated with a lattice design to generate better bone ingrowth environment. This study combines topology optimization (TO) and lattice design to acquire an optimal wedge-shaped spacer (OWS) for high tibial osteotomy (HTO) fixation. The OWS was manufactured using titanium alloy 3D printing to conduct biomechanical fatigue testing for mechanical performance validation. A solid wedge-shaped spacer (SWS) with three embedded screws was designed using the HTO model. An OWS was obtained under physiological loads through finite element (FE) analysis and TO. A deformed YM lattice with a porosity of 60% and pore size of 700 μm was filled at the OWS posterior region. The HTO mechanical performance was simulated for SWS, OWS, and commercial T-shaped plate (TP) fixations using FE analysis. The displacement/fracture patterns under OWS and TP fixations were verified using fatigue testing. The manufacturing errors for all 3D-printed OWS features were found to be less than 1%. The FE results revealed that the OWS fixation demonstrated reductions of 56.46%, 11.98%, and 64.31% in displacement, stress in the implant and bone, respectively, compared to the TP fixation. The fatigue test indicated that the OWS fixation exhibited smaller displacement for the HTO, as well as a higher load capacity, minor bone fracture collapse, and a greater number of cycles than the TP system. This study concluded that medical implants can be designed by integrating macro TO and microlattice design to provide enough mechanical strength and an environment for bone ingrowth after surgery. Both FE analysis and biomechanical fatigue tests confirmed that OWS mechanical performance with lattice design was more stable than the HTO TP fixations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.90
自引率
4.80%
发文量
81
期刊介绍: The International Journal of Bioprinting is a globally recognized publication that focuses on the advancements, scientific discoveries, and practical implementations of Bioprinting. Bioprinting, in simple terms, involves the utilization of 3D printing technology and materials that contain living cells or biological components to fabricate tissues or other biotechnological products. Our journal encompasses interdisciplinary research that spans across technology, science, and clinical applications within the expansive realm of Bioprinting.
期刊最新文献
Additive-manufactured synthetic bone model with biomimicking tunable mechanical properties for evaluation of medical implants Designing a 3D-printed medical implant with mechanically macrostructural topology and microbionic lattices: A novel wedge-shaped spacer for high tibial osteotomy and biomechanical study PBF-LB fabrication of microgrooves for induction of osteogenic differentiation of human mesenchymal stem cells Building a degradable scaffold with 3D printing using Masquelet technique to promote osteoblast differentiation and angiogenesis in chronic tibial osteomyelitis with bone defects Design of biomedical gradient porous scaffold via a minimal surface dual-unit continuous transition connection strategy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1