基于不同扫描模式和不同造影剂浓度的超重和肥胖患者腹部 CT 增强对比研究。

IF 1.7 3区 医学 Q3 INSTRUMENTS & INSTRUMENTATION Journal of X-Ray Science and Technology Pub Date : 2024-01-01 DOI:10.3233/XST-230327
Kai Gao, Ze-Peng Ma, Tian-Le Zhang, Yi-Wen Liu, Yong-Xia Zhao
{"title":"基于不同扫描模式和不同造影剂浓度的超重和肥胖患者腹部 CT 增强对比研究。","authors":"Kai Gao, Ze-Peng Ma, Tian-Le Zhang, Yi-Wen Liu, Yong-Xia Zhao","doi":"10.3233/XST-230327","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium.</p><p><strong>Methods: </strong>Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)< 30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected.</p><p><strong>Results: </strong>The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively.</p><p><strong>Conclusion: </strong>GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.</p>","PeriodicalId":49948,"journal":{"name":"Journal of X-Ray Science and Technology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative study of abdominal CT enhancement in overweight and obese patients based on different scanning modes combined with different contrast medium concentrations.\",\"authors\":\"Kai Gao, Ze-Peng Ma, Tian-Le Zhang, Yi-Wen Liu, Yong-Xia Zhao\",\"doi\":\"10.3233/XST-230327\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium.</p><p><strong>Methods: </strong>Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)< 30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected.</p><p><strong>Results: </strong>The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively.</p><p><strong>Conclusion: </strong>GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.</p>\",\"PeriodicalId\":49948,\"journal\":{\"name\":\"Journal of X-Ray Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of X-Ray Science and Technology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/XST-230327\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of X-Ray Science and Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/XST-230327","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较使用不同扫描模式和造影剂进行腹部计算机断层扫描(CT)增强的超重和肥胖患者的图像质量、碘摄入量和辐射剂量:将接受腹部 CT 增强检查的 90 名超重和肥胖患者(25 kg/m2≤ 体重指数(BMI)< 30 kg/m2 和 BMI≥30 kg/m2)随机分为三组(A、B 和 C),每组 30 人,分别使用宝石光谱成像(GSI)+320 mgI/ml、100 kVp + 370 mgI/ml 和 120 kVp + 370 mgI/ml 进行扫描。重建 A 组 50-70 千伏(间隔 5 千伏)的单色能量图像。记录并计算各组的碘摄入量和辐射剂量。采用单因素方差分析或 Kruskal-Wallis H 检验,比较 A 组与 B 组和 C 组各亚组图像的 CT 值、对比噪声比(CNR)和主观评分,并选择 A 组的最佳 KeV:结果:在 50-60 keV 下,A 组各部位的双相 CT 值和 CNR 均高于或接近于 B 组和 C 组;在 65 keV 和 70 keV 下,A 组各部位的双相 CT 值和 CNR 均接近或低于 B 组和 C 组。A 组双相图像的主观评分在 50 keV 和 55 keV 时低于 B 组和 C 组,而在 60-70 keV 时则无明显差异。与 B 组和 C 组相比,A 组的碘摄入量分别减少了 12.5%和 13.3%。A 组和 B 组的有效剂量分别比 C 组低 24.7% 和 25.8%:结论:GSI +320 mgI/ml 用于超重患者的腹部 CT 增强,既能满足图像质量要求,又能减少碘摄入量和辐射剂量,最佳 KeV 为 60 keV。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative study of abdominal CT enhancement in overweight and obese patients based on different scanning modes combined with different contrast medium concentrations.

Purpose: To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium.

Methods: Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)< 30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected.

Results: The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively.

Conclusion: GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.90
自引率
23.30%
发文量
150
审稿时长
3 months
期刊介绍: Research areas within the scope of the journal include: Interaction of x-rays with matter: x-ray phenomena, biological effects of radiation, radiation safety and optical constants X-ray sources: x-rays from synchrotrons, x-ray lasers, plasmas, and other sources, conventional or unconventional Optical elements: grazing incidence optics, multilayer mirrors, zone plates, gratings, other diffraction optics Optical instruments: interferometers, spectrometers, microscopes, telescopes, microprobes
期刊最新文献
Adaptive prior image constrained total generalized variation for low-dose dynamic cerebral perfusion CT reconstruction. A comprehensive guide to content-based image retrieval algorithms with visualsift ensembling. Multiscale unsupervised network for deformable image registration. Extracellular volume fraction of liver and pancreas using spectral CT in hypertensive patients: A comparative study. Dosimetric effect of collimator rotation on intensity modulated radiotherapy and volumetric modulated arc therapy for rectal cancer radiotherapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1