评估即刻植入和加载下颌覆盖义齿的种植体周围参数和功能效果:五年随访研究

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Oral health & preventive dentistry Pub Date : 2024-01-15 DOI:10.3290/j.ohpd.b4836045
Abdulaziz A AlHelal, Abdulaziz A Alzaid, Saad H Almujel, Mohammed Alsaloum, Khalid K Alanazi, Ramzi O Althubaitiy, Khulud A Al-Aali
{"title":"评估即刻植入和加载下颌覆盖义齿的种植体周围参数和功能效果:五年随访研究","authors":"Abdulaziz A AlHelal, Abdulaziz A Alzaid, Saad H Almujel, Mohammed Alsaloum, Khalid K Alanazi, Ramzi O Althubaitiy, Khulud A Al-Aali","doi":"10.3290/j.ohpd.b4836045","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the peri-implant parameters of immediately placed and loaded mandibular overdentures over a 5-year follow-up period.</p><p><strong>Materials and methods: </strong>All subjects who had been advised and planned for two-implant mandibular overdenture treatment were included in this study. The peri-implant parameters -including plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) as well as marginal bone loss (MBL) - were assessed. In addition, prosthodontic parameters including abutment-, implant- and denture-related complications were assessed. Patients were evaluated at follow-up visits, scheduled at 1, 12, 24, 36, 48, and 60 months. The data distribution was analysed with the Shapiro-Wilk test. Data within follow-up categories were compared using ANOVA and the Tukey-Kramer test. A p-value < 0.05 was considered statistically significant.</p><p><strong>Results: </strong>Among the 32 participants, 19 were males and 13 were females, with a mean age of 60.5 ± 7.33. The mean plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) varied over time. However, no statistically significant difference was observed in the plaque index, bleeding index and peri-implant pocket depth over time (p > 0.05). The mean value at baseline was found to be -0.9 ± 0.3. The values increased over time, with the highest value observed at 60 months 2.6 ± 0.7, which was statistically significant (p < 0.001).</p><p><strong>Conclusion: </strong>Immediately placed and loaded mandibular implant overdentures using two un-splinted implants with locator attachments showed acceptable PI, BI and PIPD at the 5-year follow-up. Statistically significantly greater marginal bone loss was observed from baseline to follow-up, but it was within acceptable limits. A moderate number of restorative and abutment complications were observed during the follow-up of IODs.</p>","PeriodicalId":19696,"journal":{"name":"Oral health & preventive dentistry","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Peri-Implant Parameters and Functional Outcome of Immediately Placed and Loaded Mandibular Overdentures: A 5-year Follow-up Study.\",\"authors\":\"Abdulaziz A AlHelal, Abdulaziz A Alzaid, Saad H Almujel, Mohammed Alsaloum, Khalid K Alanazi, Ramzi O Althubaitiy, Khulud A Al-Aali\",\"doi\":\"10.3290/j.ohpd.b4836045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the peri-implant parameters of immediately placed and loaded mandibular overdentures over a 5-year follow-up period.</p><p><strong>Materials and methods: </strong>All subjects who had been advised and planned for two-implant mandibular overdenture treatment were included in this study. The peri-implant parameters -including plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) as well as marginal bone loss (MBL) - were assessed. In addition, prosthodontic parameters including abutment-, implant- and denture-related complications were assessed. Patients were evaluated at follow-up visits, scheduled at 1, 12, 24, 36, 48, and 60 months. The data distribution was analysed with the Shapiro-Wilk test. Data within follow-up categories were compared using ANOVA and the Tukey-Kramer test. A p-value < 0.05 was considered statistically significant.</p><p><strong>Results: </strong>Among the 32 participants, 19 were males and 13 were females, with a mean age of 60.5 ± 7.33. The mean plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) varied over time. However, no statistically significant difference was observed in the plaque index, bleeding index and peri-implant pocket depth over time (p > 0.05). The mean value at baseline was found to be -0.9 ± 0.3. The values increased over time, with the highest value observed at 60 months 2.6 ± 0.7, which was statistically significant (p < 0.001).</p><p><strong>Conclusion: </strong>Immediately placed and loaded mandibular implant overdentures using two un-splinted implants with locator attachments showed acceptable PI, BI and PIPD at the 5-year follow-up. Statistically significantly greater marginal bone loss was observed from baseline to follow-up, but it was within acceptable limits. A moderate number of restorative and abutment complications were observed during the follow-up of IODs.</p>\",\"PeriodicalId\":19696,\"journal\":{\"name\":\"Oral health & preventive dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral health & preventive dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ohpd.b4836045\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral health & preventive dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ohpd.b4836045","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估即刻种植和加载下颌覆盖义齿在5年随访期内的种植体周围参数:研究对象包括所有已被建议并计划进行双种植体下颌覆盖义齿治疗的受试者。评估了种植体周围参数,包括菌斑指数(PI)、出血指数(BI)和种植体周围袋深度(PIPD)以及边缘骨量(MBL)。此外,还评估了修复参数,包括基台、种植体和义齿相关的并发症。患者分别在 1、12、24、36、48 和 60 个月时接受随访评估。数据分布采用 Shapiro-Wilk 检验进行分析。采用方差分析和Tukey-Kramer检验对随访类别内的数据进行比较。P值小于0.05为具有统计学意义:在 32 名参与者中,男性 19 人,女性 13 人,平均年龄为(60.5 ± 7.33)岁。平均斑块指数(PI)、出血指数(BI)和种植体周围窝洞深度(PIPD)随时间而变化。然而,随着时间的推移,牙菌斑指数、出血指数和种植体周围牙槽窝深度没有发现明显的统计学差异(P > 0.05)。基线平均值为-0.9 ± 0.3。随着时间的推移,这些值不断增加,最高值出现在 60 个月时,为 2.6 ± 0.7,具有显著的统计学意义(p < 0.001):结论:使用两个未夹板种植体和定位连接体的即刻种植和加载下颌种植覆盖义齿在5年的随访中显示出可接受的PI、BI和PIPD。据统计,从基线到随访期间的边缘骨量损失明显增大,但仍在可接受范围内。在对 IOD 的随访过程中,观察到了一定数量的修复和基台并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Peri-Implant Parameters and Functional Outcome of Immediately Placed and Loaded Mandibular Overdentures: A 5-year Follow-up Study.

Purpose: To evaluate the peri-implant parameters of immediately placed and loaded mandibular overdentures over a 5-year follow-up period.

Materials and methods: All subjects who had been advised and planned for two-implant mandibular overdenture treatment were included in this study. The peri-implant parameters -including plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) as well as marginal bone loss (MBL) - were assessed. In addition, prosthodontic parameters including abutment-, implant- and denture-related complications were assessed. Patients were evaluated at follow-up visits, scheduled at 1, 12, 24, 36, 48, and 60 months. The data distribution was analysed with the Shapiro-Wilk test. Data within follow-up categories were compared using ANOVA and the Tukey-Kramer test. A p-value < 0.05 was considered statistically significant.

Results: Among the 32 participants, 19 were males and 13 were females, with a mean age of 60.5 ± 7.33. The mean plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) varied over time. However, no statistically significant difference was observed in the plaque index, bleeding index and peri-implant pocket depth over time (p > 0.05). The mean value at baseline was found to be -0.9 ± 0.3. The values increased over time, with the highest value observed at 60 months 2.6 ± 0.7, which was statistically significant (p < 0.001).

Conclusion: Immediately placed and loaded mandibular implant overdentures using two un-splinted implants with locator attachments showed acceptable PI, BI and PIPD at the 5-year follow-up. Statistically significantly greater marginal bone loss was observed from baseline to follow-up, but it was within acceptable limits. A moderate number of restorative and abutment complications were observed during the follow-up of IODs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Oral health & preventive dentistry
Oral health & preventive dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.00
自引率
0.00%
发文量
51
审稿时长
>12 weeks
期刊介绍: Clinicians, general practitioners, teachers, researchers, and public health administrators will find this journal an indispensable source of essential, timely information about scientific progress in the fields of oral health and the prevention of caries, periodontal diseases, oral mucosal diseases, and dental trauma. Central topics, including oral hygiene, oral epidemiology, oral health promotion, and public health issues, are covered in peer-reviewed articles such as clinical and basic science research reports; reviews; invited focus articles, commentaries, and guest editorials; and symposium, workshop, and conference proceedings.
期刊最新文献
Self-monitoring of Oral Health Using Smartphone Selfie Powered by Artificial Intelligence: Implications for Preventive Dentistry. Does Non-surgical Periodontal Therapy With Adjunct Antimicrobial Photodynamic Therapy Help Reduce Periodontal Inflammation and Haemoglobin A1c Levels in Patients With Type-2 Diabetes Mellitus? A Systematic Review and Meta-analysis. Effect of Active Oxygen Fluid (Blue®m) as a Root Canal Irrigant Against Enterococcus Faecalis. Evaluation of Colour Changes in Nanocomposite-Based Bulk-Fill and Universal Composite Using Different Polishing Systems. The Mechanisms and Application Value of Postbiotics in Caries Prevention and Management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1