{"title":"克服立体定向放射手术单等中心容积调制弧治疗计划中多目标偏移距离造成的问题","authors":"Takaaki Ito, Kazuki Kubo, Hajime Monzen, Yuya Yanagi, Kenji Nakamura, Yusuke Sakai, Yasumasa Nishimura","doi":"10.4103/jmp.jmp_8_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the study is to investigate the impact of large target offset distances on the dose distribution and gamma passing rate (GPR) in single-isocenter multiple-target stereotactic radiosurgery (SIMT SRS) using volumetric modulated arc therapy (VMAT) with a flattening filter-free (FFF) beam from a linear accelerator.</p><p><strong>Methods: </strong>Two targets with a diameter of 1 cm were offset by \"±2, ±4, and ±6 cm from the isocenter in a verification phantom for head SRS (20 Gy/fr). The VMAT plans were created using collimator angles that ensured the two targets did not share a leaf pair from the multi-leaf collimator. To evaluate the low-dose spread intermediate dose spill (R<sub>50%</sub>), GPRs were measured with a criterion of 3%/2 mm using an electronic portal imaging device and evaluated using monitor unit (MU), modulation complexity score for VMAT (MCS<sub>v</sub>), and leaf travel (LT) parameters.</p><p><strong>Results: </strong>For offsets of 2, 4, and 6 cm, the respective parameters were: R<sub>50%</sub>, 4.75 ± 0.36, 5.13 ± 0.36, and 5.11 ± 0.33; GPR, 95.01%, 93.82%, and 90.67%; MU, 5893 ± 186, 5825 ± 286, and 5810 ± 396; MCS<sub>v</sub>, 0.24, 0.16, and 0.13; and LT, 189.21 ± 36.04, 327.69 ± 67.01, and 430.39 ± 114.34 mm. There was a spread in the low-dose region from offsets of ≥4 cm and the GPR negatively correlated with LT (<i>r</i> = -0.762). There was minimal correlation between GPR and MU or MCS<sub>v</sub>.</p><p><strong>Conclusions: </strong>In SIMT SRS VMAT plans with an FFF beam from a linear accelerator, target offsets of <4 cm from the isocenter can minimize the volume of the low-dose region receiving 10 Gy or more. During treatment planning, it is important to choose gantry, couch, and collimator angles that minimize LT and thereby improve the GPR.</p>","PeriodicalId":51719,"journal":{"name":"Journal of Medical Physics","volume":"48 4","pages":"365-372"},"PeriodicalIF":0.7000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10783189/pdf/","citationCount":"0","resultStr":"{\"title\":\"Overcoming Problems Caused by Offset Distance of Multiple Targets in Single-isocenter Volumetric Modulated Arc Therapy Planning for Stereotactic Radiosurgery.\",\"authors\":\"Takaaki Ito, Kazuki Kubo, Hajime Monzen, Yuya Yanagi, Kenji Nakamura, Yusuke Sakai, Yasumasa Nishimura\",\"doi\":\"10.4103/jmp.jmp_8_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of the study is to investigate the impact of large target offset distances on the dose distribution and gamma passing rate (GPR) in single-isocenter multiple-target stereotactic radiosurgery (SIMT SRS) using volumetric modulated arc therapy (VMAT) with a flattening filter-free (FFF) beam from a linear accelerator.</p><p><strong>Methods: </strong>Two targets with a diameter of 1 cm were offset by \\\"±2, ±4, and ±6 cm from the isocenter in a verification phantom for head SRS (20 Gy/fr). The VMAT plans were created using collimator angles that ensured the two targets did not share a leaf pair from the multi-leaf collimator. To evaluate the low-dose spread intermediate dose spill (R<sub>50%</sub>), GPRs were measured with a criterion of 3%/2 mm using an electronic portal imaging device and evaluated using monitor unit (MU), modulation complexity score for VMAT (MCS<sub>v</sub>), and leaf travel (LT) parameters.</p><p><strong>Results: </strong>For offsets of 2, 4, and 6 cm, the respective parameters were: R<sub>50%</sub>, 4.75 ± 0.36, 5.13 ± 0.36, and 5.11 ± 0.33; GPR, 95.01%, 93.82%, and 90.67%; MU, 5893 ± 186, 5825 ± 286, and 5810 ± 396; MCS<sub>v</sub>, 0.24, 0.16, and 0.13; and LT, 189.21 ± 36.04, 327.69 ± 67.01, and 430.39 ± 114.34 mm. There was a spread in the low-dose region from offsets of ≥4 cm and the GPR negatively correlated with LT (<i>r</i> = -0.762). There was minimal correlation between GPR and MU or MCS<sub>v</sub>.</p><p><strong>Conclusions: </strong>In SIMT SRS VMAT plans with an FFF beam from a linear accelerator, target offsets of <4 cm from the isocenter can minimize the volume of the low-dose region receiving 10 Gy or more. During treatment planning, it is important to choose gantry, couch, and collimator angles that minimize LT and thereby improve the GPR.</p>\",\"PeriodicalId\":51719,\"journal\":{\"name\":\"Journal of Medical Physics\",\"volume\":\"48 4\",\"pages\":\"365-372\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10783189/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jmp.jmp_8_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmp.jmp_8_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Overcoming Problems Caused by Offset Distance of Multiple Targets in Single-isocenter Volumetric Modulated Arc Therapy Planning for Stereotactic Radiosurgery.
Purpose: The purpose of the study is to investigate the impact of large target offset distances on the dose distribution and gamma passing rate (GPR) in single-isocenter multiple-target stereotactic radiosurgery (SIMT SRS) using volumetric modulated arc therapy (VMAT) with a flattening filter-free (FFF) beam from a linear accelerator.
Methods: Two targets with a diameter of 1 cm were offset by "±2, ±4, and ±6 cm from the isocenter in a verification phantom for head SRS (20 Gy/fr). The VMAT plans were created using collimator angles that ensured the two targets did not share a leaf pair from the multi-leaf collimator. To evaluate the low-dose spread intermediate dose spill (R50%), GPRs were measured with a criterion of 3%/2 mm using an electronic portal imaging device and evaluated using monitor unit (MU), modulation complexity score for VMAT (MCSv), and leaf travel (LT) parameters.
Results: For offsets of 2, 4, and 6 cm, the respective parameters were: R50%, 4.75 ± 0.36, 5.13 ± 0.36, and 5.11 ± 0.33; GPR, 95.01%, 93.82%, and 90.67%; MU, 5893 ± 186, 5825 ± 286, and 5810 ± 396; MCSv, 0.24, 0.16, and 0.13; and LT, 189.21 ± 36.04, 327.69 ± 67.01, and 430.39 ± 114.34 mm. There was a spread in the low-dose region from offsets of ≥4 cm and the GPR negatively correlated with LT (r = -0.762). There was minimal correlation between GPR and MU or MCSv.
Conclusions: In SIMT SRS VMAT plans with an FFF beam from a linear accelerator, target offsets of <4 cm from the isocenter can minimize the volume of the low-dose region receiving 10 Gy or more. During treatment planning, it is important to choose gantry, couch, and collimator angles that minimize LT and thereby improve the GPR.
期刊介绍:
JOURNAL OF MEDICAL PHYSICS is the official journal of Association of Medical Physicists of India (AMPI). The association has been bringing out a quarterly publication since 1976. Till the end of 1993, it was known as Medical Physics Bulletin, which then became Journal of Medical Physics. The main objective of the Journal is to serve as a vehicle of communication to highlight all aspects of the practice of medical radiation physics. The areas covered include all aspects of the application of radiation physics to biological sciences, radiotherapy, radiodiagnosis, nuclear medicine, dosimetry and radiation protection. Papers / manuscripts dealing with the aspects of physics related to cancer therapy / radiobiology also fall within the scope of the journal.