评估用于间接复合材料修复的高填充可流动复合材料

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of oral science Pub Date : 2024-01-16 DOI:10.2334/josnusd.23-0166
Özlem Kanar, Simge Meşeli, Bora Korkut, Serhat Köken, Dilek Tağtekin, Funda Yanıkoğlu
{"title":"评估用于间接复合材料修复的高填充可流动复合材料","authors":"Özlem Kanar, Simge Meşeli, Bora Korkut, Serhat Köken, Dilek Tağtekin, Funda Yanıkoğlu","doi":"10.2334/josnusd.23-0166","DOIUrl":null,"url":null,"abstract":"</p><p><b>Purpose:</b> To compare the shear-bond-strength (SBS) of a highly-filled-flowable composite (HFFC) and a paste-type composite for indirect composite repair and to evaluate the effect of different surface treatments (ST), concerning the composite repair protocol.</p><p><b>Methods:</b> Eighty-four 5 × 5 × 2 mm cylindrical specimens were prepared using Gradia Plus and SR Nexco indirect composite materials. The samples were thermocycled 5,000 times. According to the ST, the samples were divided into three groups (control, bur, and air-abrasion). After ST, the sample subgroups were divided into two sub-groups according to the repair material: paste-type composite and HFFC (<i>n</i> = 7). Another 5,000 cycles of aging were performed. SBS values were measured with a universal testing machine (Shimadzu, Japan). Shapiro-Wilk, 3-way ANOVA, and Tukey HSD test were used to evaluate data (<i>P</i> &lt; 0.05).</p><p><b>Results:</b> ST was considered significant for SBS (<i>P</i> &lt; 0.001). The mean values were (13.9 ± 5.7), (17.0 ± 6.4), (20.4 ± 4.9) MPa for the control, bur and phosphoric acid, and air-abrasion groups, respectively. The surface treatment and repair material interaction was considered significant for SBS (<i>P</i> = 0.044). The highest mean bond strength (24.5 ± 4.5 MPa) was observed for the interaction of SR Nexco, air-abrasion ST, and HFFC repair.</p><p><b>Conclusion:</b> Repairing with HFFC following air abrasion might enhance the SBS for indirect composite restorations.</p>\n<p></p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of a highly-filled flowable composite for the repair of indirect composites\",\"authors\":\"Özlem Kanar, Simge Meşeli, Bora Korkut, Serhat Köken, Dilek Tağtekin, Funda Yanıkoğlu\",\"doi\":\"10.2334/josnusd.23-0166\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"</p><p><b>Purpose:</b> To compare the shear-bond-strength (SBS) of a highly-filled-flowable composite (HFFC) and a paste-type composite for indirect composite repair and to evaluate the effect of different surface treatments (ST), concerning the composite repair protocol.</p><p><b>Methods:</b> Eighty-four 5 × 5 × 2 mm cylindrical specimens were prepared using Gradia Plus and SR Nexco indirect composite materials. The samples were thermocycled 5,000 times. According to the ST, the samples were divided into three groups (control, bur, and air-abrasion). After ST, the sample subgroups were divided into two sub-groups according to the repair material: paste-type composite and HFFC (<i>n</i> = 7). Another 5,000 cycles of aging were performed. SBS values were measured with a universal testing machine (Shimadzu, Japan). Shapiro-Wilk, 3-way ANOVA, and Tukey HSD test were used to evaluate data (<i>P</i> &lt; 0.05).</p><p><b>Results:</b> ST was considered significant for SBS (<i>P</i> &lt; 0.001). The mean values were (13.9 ± 5.7), (17.0 ± 6.4), (20.4 ± 4.9) MPa for the control, bur and phosphoric acid, and air-abrasion groups, respectively. The surface treatment and repair material interaction was considered significant for SBS (<i>P</i> = 0.044). The highest mean bond strength (24.5 ± 4.5 MPa) was observed for the interaction of SR Nexco, air-abrasion ST, and HFFC repair.</p><p><b>Conclusion:</b> Repairing with HFFC following air abrasion might enhance the SBS for indirect composite restorations.</p>\\n<p></p>\",\"PeriodicalId\":16646,\"journal\":{\"name\":\"Journal of oral science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of oral science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2334/josnusd.23-0166\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.23-0166","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较用于间接复合材料修复的高填充可流动复合材料(HFFC)和粘贴型复合材料的剪切-粘结-强度(SBS),并评估不同表面处理(ST)对复合材料修复方案的影响:使用 Gradia Plus 和 SR Nexco 间接复合材料制备了 84 个 5 × 5 × 2 毫米的圆柱形试样。样品经过 5000 次热循环处理。根据 ST 将样品分为三组(对照组、毛刺组和气磨组)。ST 后,根据修复材料的不同,样品分组又分为两组:粘贴型复合材料和 HFFC(n = 7)。再进行 5000 次老化循环。SBS 值用万能试验机(日本岛津)测量。采用 Shapiro-Wilk、3 方方差分析和 Tukey HSD 检验来评估数据(P < 0.05):ST 被认为对 SBS 有显著影响(P <0.001)。对照组、锉刀和磷酸组、气磨组的平均值分别为(13.9 ± 5.7)、(17.0 ± 6.4)、(20.4 ± 4.9)MPa。对于 SBS 而言,表面处理与修复材料的交互作用被认为是显著的(P = 0.044)。在 SR Nexco、气磨 ST 和 HFFC 修复的相互作用下,观察到最高的平均粘接强度(24.5 ± 4.5 MPa):结论:在气磨后使用 HFFC 进行修复可提高间接复合材料修复体的 SBS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of a highly-filled flowable composite for the repair of indirect composites

Purpose: To compare the shear-bond-strength (SBS) of a highly-filled-flowable composite (HFFC) and a paste-type composite for indirect composite repair and to evaluate the effect of different surface treatments (ST), concerning the composite repair protocol.

Methods: Eighty-four 5 × 5 × 2 mm cylindrical specimens were prepared using Gradia Plus and SR Nexco indirect composite materials. The samples were thermocycled 5,000 times. According to the ST, the samples were divided into three groups (control, bur, and air-abrasion). After ST, the sample subgroups were divided into two sub-groups according to the repair material: paste-type composite and HFFC (n = 7). Another 5,000 cycles of aging were performed. SBS values were measured with a universal testing machine (Shimadzu, Japan). Shapiro-Wilk, 3-way ANOVA, and Tukey HSD test were used to evaluate data (P < 0.05).

Results: ST was considered significant for SBS (P < 0.001). The mean values were (13.9 ± 5.7), (17.0 ± 6.4), (20.4 ± 4.9) MPa for the control, bur and phosphoric acid, and air-abrasion groups, respectively. The surface treatment and repair material interaction was considered significant for SBS (P = 0.044). The highest mean bond strength (24.5 ± 4.5 MPa) was observed for the interaction of SR Nexco, air-abrasion ST, and HFFC repair.

Conclusion: Repairing with HFFC following air abrasion might enhance the SBS for indirect composite restorations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
期刊最新文献
A micro-computed tomographic evaluation of maxillary first molar accessory root canal morphology in a Black South African subpopulation. Attitudes of general and specialist French practitioners toward stage III-IV grade C periodontitis with familial aggregation. Clinical behavior and survival of endodontically treated teeth with or without post placement: a systematic review and meta-analysis. CAD-CAM for removable partial denture fabrication after marginal mandibulectomy based on a well-adjusted pre-existing denture. Assessment of cytotoxicity, odontoblast-like differentiation, shear bond strength, and microhardness of four orthodontic adhesive composites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1