基于还原氧化石墨烯-氧化钆功能化纸的免疫传感器,用于电化学检测庆大霉素

IF 10.61 Q3 Biochemistry, Genetics and Molecular Biology Biosensors and Bioelectronics: X Pub Date : 2024-01-19 DOI:10.1016/j.biosx.2024.100442
Jayendra Kumar Himanshu , G.B.V.S. Lakshmi , Akhilesh Kumar Singh , Pratima R. Solanki
{"title":"基于还原氧化石墨烯-氧化钆功能化纸的免疫传感器,用于电化学检测庆大霉素","authors":"Jayendra Kumar Himanshu ,&nbsp;G.B.V.S. Lakshmi ,&nbsp;Akhilesh Kumar Singh ,&nbsp;Pratima R. Solanki","doi":"10.1016/j.biosx.2024.100442","DOIUrl":null,"url":null,"abstract":"<div><p>Excessive consumption of antibiotics like gentamicin (GEN) can lead to hostile effects as antibiotic resistance. Therefore, the detection is important for which, reduced graphene oxide-Gadolinium oxide nanocomposite (rGO@Gd<sub>2</sub>O<sub>3</sub> NC) was composed through co-precipitation method for the detection of GEN. The structural, morphological and functional group characterizations were done using XRD, FT-IR, SEM and TEM techniques. The cyclic voltammetry (CV) showed excellent electrocatalytic activity and superior performance towards GEN detection. Through the use of GEN monoclonal antibodies (anti-GEN) on a screen-printed electrode (SPE), a very sensitive electrochemical immunosensor was fabricated. Covalent interactions were employed to construct the electrochemical immunosensor, while bovine serum albumin (BSA) was employed as a blocking agent on the anti-GEN/rGO@Gd<sub>2</sub>O<sub>3</sub>/SPE electrode surface. The analysis of the CV response of the BSA/anti-GEN/rGO@Gd<sub>2</sub>O<sub>3</sub>/SPE bioelectrode demonstrated linear detection range from 1 pM – 100 μM, along with limit of detection (LOD) of 0.424 pM and sensitivity of 44.87 μA pM<sup>-1</sup> cm<sup>− 2</sup>. Additionally, rGO@Gd<sub>2</sub>O<sub>3</sub> immunosensor, exhibited a good level of linearity with R<sup>2</sup> value of 0.978. These findings indicate the excellent potential of the rGO@Gd<sub>2</sub>O<sub>3</sub> electrochemical immunosensor for accurately detecting GEN in spiked milk samples at different concentrations.</p></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"17 ","pages":"Article 100442"},"PeriodicalIF":10.6100,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2590137024000062/pdfft?md5=faab388e2f48a6ab8362314cdf7a22e5&pid=1-s2.0-S2590137024000062-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Reduced graphene oxide-gadolinium oxide-functionalized paper based immunosensor for electrochemical detection of gentamicin\",\"authors\":\"Jayendra Kumar Himanshu ,&nbsp;G.B.V.S. Lakshmi ,&nbsp;Akhilesh Kumar Singh ,&nbsp;Pratima R. Solanki\",\"doi\":\"10.1016/j.biosx.2024.100442\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Excessive consumption of antibiotics like gentamicin (GEN) can lead to hostile effects as antibiotic resistance. Therefore, the detection is important for which, reduced graphene oxide-Gadolinium oxide nanocomposite (rGO@Gd<sub>2</sub>O<sub>3</sub> NC) was composed through co-precipitation method for the detection of GEN. The structural, morphological and functional group characterizations were done using XRD, FT-IR, SEM and TEM techniques. The cyclic voltammetry (CV) showed excellent electrocatalytic activity and superior performance towards GEN detection. Through the use of GEN monoclonal antibodies (anti-GEN) on a screen-printed electrode (SPE), a very sensitive electrochemical immunosensor was fabricated. Covalent interactions were employed to construct the electrochemical immunosensor, while bovine serum albumin (BSA) was employed as a blocking agent on the anti-GEN/rGO@Gd<sub>2</sub>O<sub>3</sub>/SPE electrode surface. The analysis of the CV response of the BSA/anti-GEN/rGO@Gd<sub>2</sub>O<sub>3</sub>/SPE bioelectrode demonstrated linear detection range from 1 pM – 100 μM, along with limit of detection (LOD) of 0.424 pM and sensitivity of 44.87 μA pM<sup>-1</sup> cm<sup>− 2</sup>. Additionally, rGO@Gd<sub>2</sub>O<sub>3</sub> immunosensor, exhibited a good level of linearity with R<sup>2</sup> value of 0.978. These findings indicate the excellent potential of the rGO@Gd<sub>2</sub>O<sub>3</sub> electrochemical immunosensor for accurately detecting GEN in spiked milk samples at different concentrations.</p></div>\",\"PeriodicalId\":260,\"journal\":{\"name\":\"Biosensors and Bioelectronics: X\",\"volume\":\"17 \",\"pages\":\"Article 100442\"},\"PeriodicalIF\":10.6100,\"publicationDate\":\"2024-01-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2590137024000062/pdfft?md5=faab388e2f48a6ab8362314cdf7a22e5&pid=1-s2.0-S2590137024000062-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics: X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590137024000062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137024000062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

摘要

过量使用庆大霉素(GEN)等抗生素会导致抗生素耐药性的产生。因此,检测就显得尤为重要,为此,我们通过共沉淀法利用还原氧化石墨烯-氧化钆纳米复合材料(rGO@Gd2O3 NC)来检测庆大霉素。利用 XRD、FT-IR、SEM 和 TEM 技术对其结构、形态和官能团进行了表征。循环伏安法(CV)显示了其出色的电催化活性和检测 GEN 的卓越性能。通过在丝网印刷电极(SPE)上使用 GEN 单克隆抗体(抗 GEN),制备出了一种非常灵敏的电化学免疫传感器。电化学免疫传感器的构建采用了共价相互作用,而牛血清白蛋白(BSA)被用作抗 GEN/rGO@Gd2O3/SPE 电极表面的阻断剂。对 BSA/抗-GEN/rGO@Gd2O3/SPE 生物电极 CV 响应的分析表明,其线性检测范围为 1 pM - 100 μM,检测限(LOD)为 0.424 pM,灵敏度为 44.87 μA pM-1 cm- 2。此外,rGO@Gd2O3 免疫传感器表现出良好的线性关系,R2 值为 0.981。这些研究结果表明,rGO@Gd2O3 电化学免疫传感器在准确检测含有添加浓度的牛奶样品中的 GEN 方面具有极大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reduced graphene oxide-gadolinium oxide-functionalized paper based immunosensor for electrochemical detection of gentamicin

Excessive consumption of antibiotics like gentamicin (GEN) can lead to hostile effects as antibiotic resistance. Therefore, the detection is important for which, reduced graphene oxide-Gadolinium oxide nanocomposite (rGO@Gd2O3 NC) was composed through co-precipitation method for the detection of GEN. The structural, morphological and functional group characterizations were done using XRD, FT-IR, SEM and TEM techniques. The cyclic voltammetry (CV) showed excellent electrocatalytic activity and superior performance towards GEN detection. Through the use of GEN monoclonal antibodies (anti-GEN) on a screen-printed electrode (SPE), a very sensitive electrochemical immunosensor was fabricated. Covalent interactions were employed to construct the electrochemical immunosensor, while bovine serum albumin (BSA) was employed as a blocking agent on the anti-GEN/rGO@Gd2O3/SPE electrode surface. The analysis of the CV response of the BSA/anti-GEN/rGO@Gd2O3/SPE bioelectrode demonstrated linear detection range from 1 pM – 100 μM, along with limit of detection (LOD) of 0.424 pM and sensitivity of 44.87 μA pM-1 cm− 2. Additionally, rGO@Gd2O3 immunosensor, exhibited a good level of linearity with R2 value of 0.978. These findings indicate the excellent potential of the rGO@Gd2O3 electrochemical immunosensor for accurately detecting GEN in spiked milk samples at different concentrations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
期刊最新文献
Printed dry and ready-to-use in vitro diagnostic culture media devices for differentiation and antimicrobial susceptibility testing of bacteria Development of novel DNA aptamers and colorimetric nanozyme aptasensor for targeting multi-drug-resistant, invasive Salmonella typhimurium strain SMC25 Performance of label-free biosensors as a function of layer thickness Simple and sensitive method for in vitro monitoring of red blood cell viscoelasticity by Quartz Crystal Microbalance with dissipation monitoring (QCM-D) Targeted biosensors for intracellular lipid droplet content detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1