从微量采样的干燥血斑和血浆中定量检测奥希替尼及其代谢物 AZ5104 和 AZ7550 的验证化验。

IF 2.8 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Therapeutic Drug Monitoring Pub Date : 2024-06-01 Epub Date: 2024-01-24 DOI:10.1097/FTD.0000000000001157
Bharat Venkatesh, Alex Yuile, Matthew J McKay, Sathya Narayanan, Helen Wheeler, Malinda Itchins, Nick Pavlakis, Stephen J Clarke, Mark P Molloy
{"title":"从微量采样的干燥血斑和血浆中定量检测奥希替尼及其代谢物 AZ5104 和 AZ7550 的验证化验。","authors":"Bharat Venkatesh, Alex Yuile, Matthew J McKay, Sathya Narayanan, Helen Wheeler, Malinda Itchins, Nick Pavlakis, Stephen J Clarke, Mark P Molloy","doi":"10.1097/FTD.0000000000001157","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Osimertinib is an oral small-molecule tyrosine kinase receptor inhibitor used to treat non-small cell lung cancer (NSCLC) with a sensitizing epidermal growth factor receptor mutation. Patients may experience drug toxicity and require dose deescalation. The study aimed to quantitate osimertinib and its 2 active metabolites, AZ5104 and AZ7550, in microsampled dried blood spots (DBS) collected from patients with NSCLC using a hemaPEN device and compare them with plasma drug levels.</p><p><strong>Methods: </strong>A 6-min ultrahigh-performance liquid chromatography-tandem mass spectrometry method was developed and validated using plasma and DBS. The accuracy, selectivity, matrix effect, recovery, and stability were assessed using bioanalytical validation criteria. The hematocrit effect was investigated in DBS. Drug levels were measured in 15 patients with NSCLC, and the Bland-Altman method was used to compare measurements between plasma and DBS.</p><p><strong>Results: </strong>The validated assay determined accurate and precise quantities, respectively, for osimertinib in both plasma (93.2%-99.3%; 0.2%-2.3%) and DBS (96.7%-99.6%; 0.5%-10.3%) over a concentration of 1-729 ng/mL. The osimertinib metabolites, AZ5104 and AZ7550, were similarly validated in accordance with bioanalytical guidelines. For 30%-60% patient hematocrit, no hematocrit bias was observed with DBS for all analytes. The Bland-Altman method showed high concordance between plasma and DBS analyte levels. Stability experiments revealed that osimertinib and its metabolites were poorly stable in plasma at room temperature, whereas all analytes were stable in DBS for 10 days at room temperature.</p><p><strong>Conclusions: </strong>The measurement of osimertinib, AZ5104, and AZ7550 from hemaPEN microsampled DBS is a convenient and reliable approach for therapeutic drug monitoring that produces measurements consistent with plasma drug levels.</p>","PeriodicalId":23052,"journal":{"name":"Therapeutic Drug Monitoring","volume":" ","pages":"332-343"},"PeriodicalIF":2.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11078286/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Validated Assay to Quantify Osimertinib and Its Metabolites, AZ5104 and AZ7550, from Microsampled Dried Blood Spots and Plasma.\",\"authors\":\"Bharat Venkatesh, Alex Yuile, Matthew J McKay, Sathya Narayanan, Helen Wheeler, Malinda Itchins, Nick Pavlakis, Stephen J Clarke, Mark P Molloy\",\"doi\":\"10.1097/FTD.0000000000001157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Osimertinib is an oral small-molecule tyrosine kinase receptor inhibitor used to treat non-small cell lung cancer (NSCLC) with a sensitizing epidermal growth factor receptor mutation. Patients may experience drug toxicity and require dose deescalation. The study aimed to quantitate osimertinib and its 2 active metabolites, AZ5104 and AZ7550, in microsampled dried blood spots (DBS) collected from patients with NSCLC using a hemaPEN device and compare them with plasma drug levels.</p><p><strong>Methods: </strong>A 6-min ultrahigh-performance liquid chromatography-tandem mass spectrometry method was developed and validated using plasma and DBS. The accuracy, selectivity, matrix effect, recovery, and stability were assessed using bioanalytical validation criteria. The hematocrit effect was investigated in DBS. Drug levels were measured in 15 patients with NSCLC, and the Bland-Altman method was used to compare measurements between plasma and DBS.</p><p><strong>Results: </strong>The validated assay determined accurate and precise quantities, respectively, for osimertinib in both plasma (93.2%-99.3%; 0.2%-2.3%) and DBS (96.7%-99.6%; 0.5%-10.3%) over a concentration of 1-729 ng/mL. The osimertinib metabolites, AZ5104 and AZ7550, were similarly validated in accordance with bioanalytical guidelines. For 30%-60% patient hematocrit, no hematocrit bias was observed with DBS for all analytes. The Bland-Altman method showed high concordance between plasma and DBS analyte levels. Stability experiments revealed that osimertinib and its metabolites were poorly stable in plasma at room temperature, whereas all analytes were stable in DBS for 10 days at room temperature.</p><p><strong>Conclusions: </strong>The measurement of osimertinib, AZ5104, and AZ7550 from hemaPEN microsampled DBS is a convenient and reliable approach for therapeutic drug monitoring that produces measurements consistent with plasma drug levels.</p>\",\"PeriodicalId\":23052,\"journal\":{\"name\":\"Therapeutic Drug Monitoring\",\"volume\":\" \",\"pages\":\"332-343\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11078286/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Drug Monitoring\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/FTD.0000000000001157\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Drug Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/FTD.0000000000001157","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景介绍奥希替尼是一种口服小分子酪氨酸激酶受体抑制剂,用于治疗表皮生长因子受体突变的非小细胞肺癌(NSCLC)。患者可能会出现药物毒性,需要降低剂量。该研究旨在使用hemaPEN装置定量检测从NSCLC患者身上采集的微采样干血斑(DBS)中的奥西替尼及其2种活性代谢物AZ5104和AZ7550,并将其与血浆药物水平进行比较:方法:利用血浆和干血样,开发并验证了 6 分钟超高效液相色谱-串联质谱法。采用生物分析验证标准评估了该方法的准确性、选择性、基质效应、回收率和稳定性。在 DBS 中研究了血细胞比容的影响。对 15 名 NSCLC 患者的药物水平进行了测定,并采用 Bland-Altman 法对血浆和 DBS 的测定结果进行了比较:结果:经过验证的检测方法能准确、精确地测定血浆(93.2%-99.3%;0.2%-2.3%)和DBS(96.7%-99.6%;0.5%-10.3%)中1-729纳克/毫升浓度范围内的奥希替尼含量。奥西替尼代谢物 AZ5104 和 AZ7550 也同样按照生物分析指南进行了验证。在患者血细胞比容为 30%-60% 的情况下,所有分析物的 DBS 方法均未观察到血细胞比容偏差。Bland-Altman 方法显示血浆和 DBS 分析物水平高度一致。稳定性实验表明,奥希替尼及其代谢物在室温下的稳定性很差,而所有分析物在室温下的 DBS 中都能稳定 10 天:利用 hemaPEN 微采样 DBS 测量奥希替尼、AZ5104 和 AZ7550 是一种方便可靠的治疗药物监测方法,其测量结果与血浆药物水平一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Validated Assay to Quantify Osimertinib and Its Metabolites, AZ5104 and AZ7550, from Microsampled Dried Blood Spots and Plasma.

Background: Osimertinib is an oral small-molecule tyrosine kinase receptor inhibitor used to treat non-small cell lung cancer (NSCLC) with a sensitizing epidermal growth factor receptor mutation. Patients may experience drug toxicity and require dose deescalation. The study aimed to quantitate osimertinib and its 2 active metabolites, AZ5104 and AZ7550, in microsampled dried blood spots (DBS) collected from patients with NSCLC using a hemaPEN device and compare them with plasma drug levels.

Methods: A 6-min ultrahigh-performance liquid chromatography-tandem mass spectrometry method was developed and validated using plasma and DBS. The accuracy, selectivity, matrix effect, recovery, and stability were assessed using bioanalytical validation criteria. The hematocrit effect was investigated in DBS. Drug levels were measured in 15 patients with NSCLC, and the Bland-Altman method was used to compare measurements between plasma and DBS.

Results: The validated assay determined accurate and precise quantities, respectively, for osimertinib in both plasma (93.2%-99.3%; 0.2%-2.3%) and DBS (96.7%-99.6%; 0.5%-10.3%) over a concentration of 1-729 ng/mL. The osimertinib metabolites, AZ5104 and AZ7550, were similarly validated in accordance with bioanalytical guidelines. For 30%-60% patient hematocrit, no hematocrit bias was observed with DBS for all analytes. The Bland-Altman method showed high concordance between plasma and DBS analyte levels. Stability experiments revealed that osimertinib and its metabolites were poorly stable in plasma at room temperature, whereas all analytes were stable in DBS for 10 days at room temperature.

Conclusions: The measurement of osimertinib, AZ5104, and AZ7550 from hemaPEN microsampled DBS is a convenient and reliable approach for therapeutic drug monitoring that produces measurements consistent with plasma drug levels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Therapeutic Drug Monitoring
Therapeutic Drug Monitoring 医学-毒理学
CiteScore
5.00
自引率
8.00%
发文量
213
审稿时长
4-8 weeks
期刊介绍: Therapeutic Drug Monitoring is a peer-reviewed, multidisciplinary journal directed to an audience of pharmacologists, clinical chemists, laboratorians, pharmacists, drug researchers and toxicologists. It fosters the exchange of knowledge among the various disciplines–clinical pharmacology, pathology, toxicology, analytical chemistry–that share a common interest in Therapeutic Drug Monitoring. The journal presents studies detailing the various factors that affect the rate and extent drugs are absorbed, metabolized, and excreted. Regular features include review articles on specific classes of drugs, original articles, case reports, technical notes, and continuing education articles.
期刊最新文献
Midazolam Boosting With Cobicistat in a Patient With Drug-Resistant Epilepsy and Focal Status Epilepticus. New Developments and Therapeutic Drug Monitoring Options in Costimulatory Blockade in Solid Organ Transplantation: A Systematic Critical Review. Implementation of Volumetric Finger-Prick Self-Sampling for TDM of Immunosuppressants After Kidney Transplantation: Lessons Learned from the Practice. Examining Whole Blood, Total and Free Plasma Tacrolimus in Elderly Kidney Transplant Recipients. Precision Dosing of Intravenous Tocilizumab: Development of Pharmacokinetic Model-Derived Tapering Strategies for Patients With Rheumatoid Arthritis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1