从经济、环境和稳健性角度评估采用无柱捕获替代品的端到端连续抗体生产。

IF 2.5 3区 生物学 Q3 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Biotechnology Progress Pub Date : 2024-01-30 DOI:10.1002/btpr.3427
Catarina P. G. Neves, Jonathan L. Coffman, Suzanne S. Farid
{"title":"从经济、环境和稳健性角度评估采用无柱捕获替代品的端到端连续抗体生产。","authors":"Catarina P. G. Neves,&nbsp;Jonathan L. Coffman,&nbsp;Suzanne S. Farid","doi":"10.1002/btpr.3427","DOIUrl":null,"url":null,"abstract":"<p>Process intensification efforts have renewed interest in the potential of end-to-end continuous manufacture with column-free capture alternatives. This article describes a decisional tool that encompasses mass balance and design equations, process economics, stochastic simulation and multi-criteria decision-making and enables the evaluation of different batch, and continuous flowsheets for monoclonal antibody (mAb) manufacture. The traditional batch process was compared with end-to-end continuous bioprocesses with either protein A capture or column-free capture employing aqueous two-phase extraction or precipitation from economic, environmental, and robustness perspectives. The cost of goods analysis predicted that continuous flowsheets could offer substantial cost savings (~20%–40%) over the batch process at low and medium annual commercial demands (100–500 kg); however, at tonnage demands they resulted in either comparable or higher costs. Comparing the continuous options, the continuous flowsheets with protein A or precipitation yielded similar COG/g values, while aqueous two-phase extraction presented higher costs. The analysis of overall process mass intensities accounting for water and consumables suggested that the continuous flowsheet with protein A would result in the lowest environmental burden. When the economic, environmental, and operational criteria were reconciled using multi-criteria decision-making analysis, the continuous protein A-based flowsheet was found to be the most favorable. A target analysis highlighted the need for process improvements in the following parameters to reduce the manufacturing costs of the continuous column-free capture options below that of protein A: the perfusion volumetric productivity, the harvested cell culture fluid percentage in column-free operations, the column-free step yields along with the implementation of buffer concentrates.</p>","PeriodicalId":8856,"journal":{"name":"Biotechnology Progress","volume":"40 4","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/btpr.3427","citationCount":"0","resultStr":"{\"title\":\"Evaluating end-to-end continuous antibody manufacture with column-free capture alternatives from economic, environmental, and robustness perspectives\",\"authors\":\"Catarina P. G. Neves,&nbsp;Jonathan L. Coffman,&nbsp;Suzanne S. Farid\",\"doi\":\"10.1002/btpr.3427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Process intensification efforts have renewed interest in the potential of end-to-end continuous manufacture with column-free capture alternatives. This article describes a decisional tool that encompasses mass balance and design equations, process economics, stochastic simulation and multi-criteria decision-making and enables the evaluation of different batch, and continuous flowsheets for monoclonal antibody (mAb) manufacture. The traditional batch process was compared with end-to-end continuous bioprocesses with either protein A capture or column-free capture employing aqueous two-phase extraction or precipitation from economic, environmental, and robustness perspectives. The cost of goods analysis predicted that continuous flowsheets could offer substantial cost savings (~20%–40%) over the batch process at low and medium annual commercial demands (100–500 kg); however, at tonnage demands they resulted in either comparable or higher costs. Comparing the continuous options, the continuous flowsheets with protein A or precipitation yielded similar COG/g values, while aqueous two-phase extraction presented higher costs. The analysis of overall process mass intensities accounting for water and consumables suggested that the continuous flowsheet with protein A would result in the lowest environmental burden. When the economic, environmental, and operational criteria were reconciled using multi-criteria decision-making analysis, the continuous protein A-based flowsheet was found to be the most favorable. A target analysis highlighted the need for process improvements in the following parameters to reduce the manufacturing costs of the continuous column-free capture options below that of protein A: the perfusion volumetric productivity, the harvested cell culture fluid percentage in column-free operations, the column-free step yields along with the implementation of buffer concentrates.</p>\",\"PeriodicalId\":8856,\"journal\":{\"name\":\"Biotechnology Progress\",\"volume\":\"40 4\",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-01-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/btpr.3427\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotechnology Progress\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/btpr.3427\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology Progress","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/btpr.3427","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

工艺强化工作重新激发了人们对采用无色谱柱捕获替代技术进行端到端连续生产的潜力的兴趣。本文介绍了一种决策工具,该工具包含质量平衡和设计方程、工艺经济学、随机模拟和多标准决策,可对单克隆抗体(mAb)生产的不同批次和连续流程进行评估。从经济、环境和稳健性的角度,比较了传统的间歇式工艺和端到端的连续式生物工艺,前者采用蛋白 A 捕捉法,后者则采用水性两相萃取或沉淀的无柱捕获法。根据商品成本分析预测,在中低年商业需求量(100-500 千克)条件下,连续式工艺流程比间歇式工艺流程可节省大量成本(约 20%-40%);但在吨位需求条件下,其成本与间歇式工艺流程相当或更高。在对连续式方案进行比较时,采用蛋白 A 或沉淀法的连续式流程图的 COG/g 值相近,而采用水基两相萃取法的成本较高。对水和消耗品的总体工艺质量强度的分析表明,使用蛋白质 A 的连续流程会带来最低的环境负担。当使用多标准决策分析来协调经济、环境和操作标准时,发现基于蛋白质 A 的连续流程图最为有利。目标分析突出表明,需要对以下参数进行工艺改进,以将连续无柱捕获方案的生产成本降至低于蛋白 A 方案的成本:灌流容积生产率、无柱操作中收获的细胞培养液百分比、无柱步骤产量以及缓冲浓缩物的使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluating end-to-end continuous antibody manufacture with column-free capture alternatives from economic, environmental, and robustness perspectives

Process intensification efforts have renewed interest in the potential of end-to-end continuous manufacture with column-free capture alternatives. This article describes a decisional tool that encompasses mass balance and design equations, process economics, stochastic simulation and multi-criteria decision-making and enables the evaluation of different batch, and continuous flowsheets for monoclonal antibody (mAb) manufacture. The traditional batch process was compared with end-to-end continuous bioprocesses with either protein A capture or column-free capture employing aqueous two-phase extraction or precipitation from economic, environmental, and robustness perspectives. The cost of goods analysis predicted that continuous flowsheets could offer substantial cost savings (~20%–40%) over the batch process at low and medium annual commercial demands (100–500 kg); however, at tonnage demands they resulted in either comparable or higher costs. Comparing the continuous options, the continuous flowsheets with protein A or precipitation yielded similar COG/g values, while aqueous two-phase extraction presented higher costs. The analysis of overall process mass intensities accounting for water and consumables suggested that the continuous flowsheet with protein A would result in the lowest environmental burden. When the economic, environmental, and operational criteria were reconciled using multi-criteria decision-making analysis, the continuous protein A-based flowsheet was found to be the most favorable. A target analysis highlighted the need for process improvements in the following parameters to reduce the manufacturing costs of the continuous column-free capture options below that of protein A: the perfusion volumetric productivity, the harvested cell culture fluid percentage in column-free operations, the column-free step yields along with the implementation of buffer concentrates.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biotechnology Progress
Biotechnology Progress 工程技术-生物工程与应用微生物
CiteScore
6.50
自引率
3.40%
发文量
83
审稿时长
4 months
期刊介绍: Biotechnology Progress , an official, bimonthly publication of the American Institute of Chemical Engineers and its technological community, the Society for Biological Engineering, features peer-reviewed research articles, reviews, and descriptions of emerging techniques for the development and design of new processes, products, and devices for the biotechnology, biopharmaceutical and bioprocess industries. Widespread interest includes application of biological and engineering principles in fields such as applied cellular physiology and metabolic engineering, biocatalysis and bioreactor design, bioseparations and downstream processing, cell culture and tissue engineering, biosensors and process control, bioinformatics and systems biology, biomaterials and artificial organs, stem cell biology and genetics, and plant biology and food science. Manuscripts concerning the design of related processes, products, or devices are also encouraged. Four types of manuscripts are printed in the Journal: Research Papers, Topical or Review Papers, Letters to the Editor, and R & D Notes.
期刊最新文献
Electrospun gelatin/hyaluronic acid nanofibers as a platform for uric acid delivery to neural tissue. Non-thermal plasma decontamination of microbes: a state of the art. Mechanistic model of minute virus of mice elution behavior in anion exchange chromatography purification. Comparing in silico flowsheet optimization strategies in biopharmaceutical downstream processes. General strategies for IgG-like bispecific antibody purification.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1