{"title":"接受起搏器或除颤器手术患者的设备感染:使用 PADIT 评分进行风险分层。","authors":"John de Heide, Marisa van der Graaf, Marijn J Holl, Mark G Hoogendijk, Rohit E Bhagwandien, Sip A Wijchers, Dominic A M J Theuns, Tamas Szili-Torok, Felix Zijlstra, Mattie J Lenzen, Sing-Chien Yap","doi":"10.1007/s10840-024-01759-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center.</p><p><strong>Methods: </strong>This was a retrospective single-center study of consecutive patients undergoing a CIED procedure between January 2016 and November 2021. Patients who received an antibacterial envelope were excluded from this study. The primary endpoint was hospitalization for a CIED infection in the first year after the procedure.</p><p><strong>Results: </strong>A total of 2333 CIED procedures were performed in the study period (mean age 61.6 ± 16.3 years, male sex 64.5%, previous CIED infection 1.7%, immunocompromised 5.4%). The median PADIT score was 4 (interquartile range, 2-6). CIED infection occurred in 10 patients (0.43%). The PADIT score had good discrimination in predicting major CIED infection (C-statistic 0.70; 95% confidence interval [CI] 0.54 to 0.86, P = 0.03). Using an optimal PADIT score cut-off value of 7, the risk of CIED infection was higher in the patients with a PADIT score of ≥ 7 in comparison to those with a lower PADIT score (1.23% vs. 0.26%, P = 0.02; odds ratio 4.8, 95% CI 1.4 to 16.6, P = 0.01).</p><p><strong>Conclusions: </strong>The PADIT score is a clinically useful score for identifying patients at high risk of developing CIED infection. The use of an antibacterial envelope in these high-risk patients may be cost-effective.</p>","PeriodicalId":16202,"journal":{"name":"Journal of Interventional Cardiac Electrophysiology","volume":" ","pages":"1419-1426"},"PeriodicalIF":2.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379746/pdf/","citationCount":"0","resultStr":"{\"title\":\"Device infection in patients undergoing pacemaker or defibrillator surgery: risk stratification using the PADIT score.\",\"authors\":\"John de Heide, Marisa van der Graaf, Marijn J Holl, Mark G Hoogendijk, Rohit E Bhagwandien, Sip A Wijchers, Dominic A M J Theuns, Tamas Szili-Torok, Felix Zijlstra, Mattie J Lenzen, Sing-Chien Yap\",\"doi\":\"10.1007/s10840-024-01759-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center.</p><p><strong>Methods: </strong>This was a retrospective single-center study of consecutive patients undergoing a CIED procedure between January 2016 and November 2021. Patients who received an antibacterial envelope were excluded from this study. The primary endpoint was hospitalization for a CIED infection in the first year after the procedure.</p><p><strong>Results: </strong>A total of 2333 CIED procedures were performed in the study period (mean age 61.6 ± 16.3 years, male sex 64.5%, previous CIED infection 1.7%, immunocompromised 5.4%). The median PADIT score was 4 (interquartile range, 2-6). CIED infection occurred in 10 patients (0.43%). The PADIT score had good discrimination in predicting major CIED infection (C-statistic 0.70; 95% confidence interval [CI] 0.54 to 0.86, P = 0.03). Using an optimal PADIT score cut-off value of 7, the risk of CIED infection was higher in the patients with a PADIT score of ≥ 7 in comparison to those with a lower PADIT score (1.23% vs. 0.26%, P = 0.02; odds ratio 4.8, 95% CI 1.4 to 16.6, P = 0.01).</p><p><strong>Conclusions: </strong>The PADIT score is a clinically useful score for identifying patients at high risk of developing CIED infection. The use of an antibacterial envelope in these high-risk patients may be cost-effective.</p>\",\"PeriodicalId\":16202,\"journal\":{\"name\":\"Journal of Interventional Cardiac Electrophysiology\",\"volume\":\" \",\"pages\":\"1419-1426\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379746/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Interventional Cardiac Electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10840-024-01759-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interventional Cardiac Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10840-024-01759-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:对心脏植入式电子装置(CIED)感染高风险患者使用抗菌包膜具有成本效益。临床风险评分可帮助识别这些高风险患者。本研究旨在评估 PADIT 评分在三级学术中心接受 CIED 手术患者中识别高风险患者的能力:这是一项回顾性单中心研究,研究对象为2016年1月至2021年11月期间接受CIED手术的连续患者。本研究不包括接受抗菌包膜治疗的患者。主要终点是术后第一年内因CIED感染而住院:研究期间共进行了2333例CIED手术(平均年龄61.6±16.3岁,男性占64.5%,既往CIED感染1.7%,免疫力低下5.4%)。PADIT评分中位数为4分(四分位间范围为2-6分)。10名患者(0.43%)感染了CIED。PADIT评分在预测重大CIED感染方面具有良好的区分度(C统计量为0.70;95%置信区间[CI] 0.54至0.86,P = 0.03)。采用最佳的PADIT评分临界值7,与PADIT评分较低的患者相比,PADIT评分≥7的患者发生CIED感染的风险更高(1.23% vs. 0.26%,P = 0.02;几率比4.8,95% CI 1.4 to 16.6,P = 0.01):PADIT评分是一种临床实用的评分方法,可用于识别CIED感染高风险患者。对这些高危患者使用抗菌包膜可能具有成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Device infection in patients undergoing pacemaker or defibrillator surgery: risk stratification using the PADIT score.

Background: The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center.

Methods: This was a retrospective single-center study of consecutive patients undergoing a CIED procedure between January 2016 and November 2021. Patients who received an antibacterial envelope were excluded from this study. The primary endpoint was hospitalization for a CIED infection in the first year after the procedure.

Results: A total of 2333 CIED procedures were performed in the study period (mean age 61.6 ± 16.3 years, male sex 64.5%, previous CIED infection 1.7%, immunocompromised 5.4%). The median PADIT score was 4 (interquartile range, 2-6). CIED infection occurred in 10 patients (0.43%). The PADIT score had good discrimination in predicting major CIED infection (C-statistic 0.70; 95% confidence interval [CI] 0.54 to 0.86, P = 0.03). Using an optimal PADIT score cut-off value of 7, the risk of CIED infection was higher in the patients with a PADIT score of ≥ 7 in comparison to those with a lower PADIT score (1.23% vs. 0.26%, P = 0.02; odds ratio 4.8, 95% CI 1.4 to 16.6, P = 0.01).

Conclusions: The PADIT score is a clinically useful score for identifying patients at high risk of developing CIED infection. The use of an antibacterial envelope in these high-risk patients may be cost-effective.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.30
自引率
11.10%
发文量
320
审稿时长
4-8 weeks
期刊介绍: The Journal of Interventional Cardiac Electrophysiology is an international publication devoted to fostering research in and development of interventional techniques and therapies for the management of cardiac arrhythmias. It is designed primarily to present original research studies and scholarly scientific reviews of basic and applied science and clinical research in this field. The Journal will adopt a multidisciplinary approach to link physical, experimental, and clinical sciences as applied to the development of and practice in interventional electrophysiology. The Journal will examine techniques ranging from molecular, chemical and pharmacologic therapies to device and ablation technology. Accordingly, original research in clinical, epidemiologic and basic science arenas will be considered for publication. Applied engineering or physical science studies pertaining to interventional electrophysiology will be encouraged. The Journal is committed to providing comprehensive and detailed treatment of major interventional therapies and innovative techniques in a structured and clinically relevant manner. It is directed at clinical practitioners and investigators in the rapidly growing field of interventional electrophysiology. The editorial staff and board reflect this bias and include noted international experts in this area with a wealth of expertise in basic and clinical investigation. Peer review of all submissions, conflict of interest guidelines and periodic editorial board review of all Journal policies have been established.
期刊最新文献
A new stepwise approach to minimize phrenic nerve injury during cryoballoon pulmonary vein isolation. Catheter ablation in rate-controlled atrial fibrillation with severely reduced ejection fraction: intervention for irregularity-mediated cardiomyopathy. Efficacy, safety, and somatosensory comparison of pulsed-field ablation and thermal ablation: outcomes from a 2-year follow-up. Differential and synergistic effects of right and left atrial ganglionated plexi ablation in patients undergoing cardioneuroablation: results from the ELEGANCE multicenter study. Upstream targeting for the prevention of atrial fibrillation: Targeting Risk Interventions and Metformin for Atrial Fibrillation (TRIM-AF)-rationale and study design.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1