电分析概述:毒药铊的测定

IF 4.1 Q1 CHEMISTRY, ANALYTICAL Talanta Open Pub Date : 2024-01-29 DOI:10.1016/j.talo.2024.100291
Robert D. Crapnell, Craig E. Banks
{"title":"电分析概述:毒药铊的测定","authors":"Robert D. Crapnell,&nbsp;Craig E. Banks","doi":"10.1016/j.talo.2024.100291","DOIUrl":null,"url":null,"abstract":"<div><p>In this overview, we explore the electroanalytical determination of the poisoner's poison: thallium. Thallium was named after the Greek word \"thallos,\" meaning \"green shoot\" or \"twig,\" due to its bright green spectral emission lines. It is toxic, tasteless, odourless and dissolves into water, and has been used by murderers as a challenging poison to detect and there is the need for the analytical determination of thallium. Laboratory based analytical instrumentation provide a routine methodology to measure thallium, but there is scope to develop in-the-field analytical measurements that are comparable to laboratory equipment and in some cases, they can provide even more sensitive analytical approaches. Electrochemistry can support such endeavours, where instrumentation are readily portable where electroanalytical sensors provide highly selective and sensitive outputs but yet are economical to support on-site analysis. In this review, we provide an electroanalytical overview of the current research directed toward the measurement of thallium and offer insights to future research.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2024-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666831924000055/pdfft?md5=23507a9dfded8cfa9fcb62f63dcbdb73&pid=1-s2.0-S2666831924000055-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Electroanalysis overview: The determination of the poisoner's poison, thallium\",\"authors\":\"Robert D. Crapnell,&nbsp;Craig E. Banks\",\"doi\":\"10.1016/j.talo.2024.100291\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this overview, we explore the electroanalytical determination of the poisoner's poison: thallium. Thallium was named after the Greek word \\\"thallos,\\\" meaning \\\"green shoot\\\" or \\\"twig,\\\" due to its bright green spectral emission lines. It is toxic, tasteless, odourless and dissolves into water, and has been used by murderers as a challenging poison to detect and there is the need for the analytical determination of thallium. Laboratory based analytical instrumentation provide a routine methodology to measure thallium, but there is scope to develop in-the-field analytical measurements that are comparable to laboratory equipment and in some cases, they can provide even more sensitive analytical approaches. Electrochemistry can support such endeavours, where instrumentation are readily portable where electroanalytical sensors provide highly selective and sensitive outputs but yet are economical to support on-site analysis. In this review, we provide an electroanalytical overview of the current research directed toward the measurement of thallium and offer insights to future research.</p></div>\",\"PeriodicalId\":436,\"journal\":{\"name\":\"Talanta Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-01-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666831924000055/pdfft?md5=23507a9dfded8cfa9fcb62f63dcbdb73&pid=1-s2.0-S2666831924000055-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666831924000055\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831924000055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在本综述中,我们将探讨电分析法测定毒药的方法:铊。铊的名字来源于希腊语 "thallos",意为 "绿芽 "或 "树枝",这是因为它具有明亮的绿色光谱发射线。铊有毒、无味、无臭,可溶解于水,曾被谋杀犯用来作为一种难以检测的毒药,因此有必要对铊进行分析测定。基于实验室的分析仪器提供了测量铊的常规方法,但还可以开发与实验室设备相当的现场分析测量方法,在某些情况下,它们甚至可以提供更灵敏的分析方法。电化学可为此类工作提供支持,因为仪器便于携带,电分析传感器可提供高选择性和高灵敏度的输出结果,而且经济实惠,可支持现场分析。在本综述中,我们将概述目前针对铊测量的电分析研究,并对未来研究提出见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electroanalysis overview: The determination of the poisoner's poison, thallium

In this overview, we explore the electroanalytical determination of the poisoner's poison: thallium. Thallium was named after the Greek word "thallos," meaning "green shoot" or "twig," due to its bright green spectral emission lines. It is toxic, tasteless, odourless and dissolves into water, and has been used by murderers as a challenging poison to detect and there is the need for the analytical determination of thallium. Laboratory based analytical instrumentation provide a routine methodology to measure thallium, but there is scope to develop in-the-field analytical measurements that are comparable to laboratory equipment and in some cases, they can provide even more sensitive analytical approaches. Electrochemistry can support such endeavours, where instrumentation are readily portable where electroanalytical sensors provide highly selective and sensitive outputs but yet are economical to support on-site analysis. In this review, we provide an electroanalytical overview of the current research directed toward the measurement of thallium and offer insights to future research.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Rapid classification of rice according to storage duration via near-infrared spectroscopy and machine learning Measurement uncertainty revealed: The impacts of Certified Reference Material (CRM) on cannabinoid concentrations in the cannabis testing industry Phage based biosensors: Enhancing early detection of emerging pathogens in diagnostics Comparison of Head Space Solid Phase Micro Extraction with Conventional and Comprehensive Gas Chromatography Mass Spectrometry for Volatile Profiling of Irish whiskey Emerging techniques for the trace elemental analysis of plants and food-based extracts: A comprehensive review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1