Alexey Kozinetz, Bogdan Sus, Olga Tsymbalyuk, Sergii Litvinenko
{"title":"作为乳酸脱氢酶活性实时测定系统的光电重组传感器","authors":"Alexey Kozinetz, Bogdan Sus, Olga Tsymbalyuk, Sergii Litvinenko","doi":"10.1016/j.sbsr.2024.100620","DOIUrl":null,"url":null,"abstract":"<div><p>The application of a recombination sensor for real-time detection of Lactate Dehydrogenase (LDH) activities has been demonstrated. LDH activity in biological fluids, particularly in blood serum, is a critical diagnostic indicator of human health. Therefore, the development of methods for monitoring it remains a crucial task in modern bioengineering. The parameter directly measured in real-time is the photocurrent through a deep-barrier structure under light illumination from the region of strong optical absorption in silicon. The detection of enzyme presence can be achieved because the flow of the dehydrogenase reaction (in the presence of LDH activation) is accompanied by changes in charge at the system's interface. Such a change in the effective charge of the reactants can be detected through the amplitude of the sensor structure's photocurrent. The main factor in this approach is the influence on the recombination center parameters at the interface. It has been shown that the combined use of modulated signal illumination and constant illumination allows obtaining additional information about the analyte and reaction kinetics. A promising approach is proposed, which can be considered a simple and sensitive method for real-time detection of lactate dehydrogenase activity.</p></div>","PeriodicalId":424,"journal":{"name":"Sensing and Bio-Sensing Research","volume":"43 ","pages":"Article 100620"},"PeriodicalIF":5.4000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2214180424000023/pdfft?md5=130b6c0828d6be014dd94043819b7e9e&pid=1-s2.0-S2214180424000023-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Photovoltaic recombination sensor as system for real-time determination of lactate dehydrogenase activity\",\"authors\":\"Alexey Kozinetz, Bogdan Sus, Olga Tsymbalyuk, Sergii Litvinenko\",\"doi\":\"10.1016/j.sbsr.2024.100620\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The application of a recombination sensor for real-time detection of Lactate Dehydrogenase (LDH) activities has been demonstrated. LDH activity in biological fluids, particularly in blood serum, is a critical diagnostic indicator of human health. Therefore, the development of methods for monitoring it remains a crucial task in modern bioengineering. The parameter directly measured in real-time is the photocurrent through a deep-barrier structure under light illumination from the region of strong optical absorption in silicon. The detection of enzyme presence can be achieved because the flow of the dehydrogenase reaction (in the presence of LDH activation) is accompanied by changes in charge at the system's interface. Such a change in the effective charge of the reactants can be detected through the amplitude of the sensor structure's photocurrent. The main factor in this approach is the influence on the recombination center parameters at the interface. It has been shown that the combined use of modulated signal illumination and constant illumination allows obtaining additional information about the analyte and reaction kinetics. A promising approach is proposed, which can be considered a simple and sensitive method for real-time detection of lactate dehydrogenase activity.</p></div>\",\"PeriodicalId\":424,\"journal\":{\"name\":\"Sensing and Bio-Sensing Research\",\"volume\":\"43 \",\"pages\":\"Article 100620\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2214180424000023/pdfft?md5=130b6c0828d6be014dd94043819b7e9e&pid=1-s2.0-S2214180424000023-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensing and Bio-Sensing Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214180424000023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing and Bio-Sensing Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214180424000023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Photovoltaic recombination sensor as system for real-time determination of lactate dehydrogenase activity
The application of a recombination sensor for real-time detection of Lactate Dehydrogenase (LDH) activities has been demonstrated. LDH activity in biological fluids, particularly in blood serum, is a critical diagnostic indicator of human health. Therefore, the development of methods for monitoring it remains a crucial task in modern bioengineering. The parameter directly measured in real-time is the photocurrent through a deep-barrier structure under light illumination from the region of strong optical absorption in silicon. The detection of enzyme presence can be achieved because the flow of the dehydrogenase reaction (in the presence of LDH activation) is accompanied by changes in charge at the system's interface. Such a change in the effective charge of the reactants can be detected through the amplitude of the sensor structure's photocurrent. The main factor in this approach is the influence on the recombination center parameters at the interface. It has been shown that the combined use of modulated signal illumination and constant illumination allows obtaining additional information about the analyte and reaction kinetics. A promising approach is proposed, which can be considered a simple and sensitive method for real-time detection of lactate dehydrogenase activity.
期刊介绍:
Sensing and Bio-Sensing Research is an open access journal dedicated to the research, design, development, and application of bio-sensing and sensing technologies. The editors will accept research papers, reviews, field trials, and validation studies that are of significant relevance. These submissions should describe new concepts, enhance understanding of the field, or offer insights into the practical application, manufacturing, and commercialization of bio-sensing and sensing technologies.
The journal covers a wide range of topics, including sensing principles and mechanisms, new materials development for transducers and recognition components, fabrication technology, and various types of sensors such as optical, electrochemical, mass-sensitive, gas, biosensors, and more. It also includes environmental, process control, and biomedical applications, signal processing, chemometrics, optoelectronic, mechanical, thermal, and magnetic sensors, as well as interface electronics. Additionally, it covers sensor systems and applications, µTAS (Micro Total Analysis Systems), development of solid-state devices for transducing physical signals, and analytical devices incorporating biological materials.