牙龈微循环激光多普勒血流测量仪的再现性。对六种不同方案的研究

IF 2.9 4区 医学 Q2 PERIPHERAL VASCULAR DISEASE Microvascular research Pub Date : 2024-01-30 DOI:10.1016/j.mvr.2024.104666
Aida Ajan , Karin Roberg , Ingemar Fredriksson , Jahan Abtahi
{"title":"牙龈微循环激光多普勒血流测量仪的再现性。对六种不同方案的研究","authors":"Aida Ajan ,&nbsp;Karin Roberg ,&nbsp;Ingemar Fredriksson ,&nbsp;Jahan Abtahi","doi":"10.1016/j.mvr.2024.104666","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva.</p></div><div><h3>Methods</h3><p>Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 °C, 3; LDF with thermoprobe 45 °C, 4; LDF with thermoprobe 42 °C and MN, 5; LDF with thermoprobe 45 °C and MN and 6; LDF with MN.</p></div><div><h3>Results</h3><p>Intra-individual reproducibility was assessed by the within-subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9–10.3 and ICC 0.82–0.93. The topically applied MN yielded increased blood flow.</p></div><div><h3>Conclusion</h3><p>This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.</p></div>","PeriodicalId":18534,"journal":{"name":"Microvascular research","volume":"153 ","pages":"Article 104666"},"PeriodicalIF":2.9000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0026286224000153/pdfft?md5=dbdab5af41c701f75c44eb89532ce89a&pid=1-s2.0-S0026286224000153-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols\",\"authors\":\"Aida Ajan ,&nbsp;Karin Roberg ,&nbsp;Ingemar Fredriksson ,&nbsp;Jahan Abtahi\",\"doi\":\"10.1016/j.mvr.2024.104666\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><p>Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva.</p></div><div><h3>Methods</h3><p>Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 °C, 3; LDF with thermoprobe 45 °C, 4; LDF with thermoprobe 42 °C and MN, 5; LDF with thermoprobe 45 °C and MN and 6; LDF with MN.</p></div><div><h3>Results</h3><p>Intra-individual reproducibility was assessed by the within-subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9–10.3 and ICC 0.82–0.93. The topically applied MN yielded increased blood flow.</p></div><div><h3>Conclusion</h3><p>This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.</p></div>\",\"PeriodicalId\":18534,\"journal\":{\"name\":\"Microvascular research\",\"volume\":\"153 \",\"pages\":\"Article 104666\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-01-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0026286224000153/pdfft?md5=dbdab5af41c701f75c44eb89532ce89a&pid=1-s2.0-S0026286224000153-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microvascular research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0026286224000153\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microvascular research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0026286224000153","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

目的激光多普勒血流测量仪(LDF)是一种评估组织血流的无创技术,但提高其再现性将有助于开展纵向研究。本研究的目的是评估激光多普勒血流测量仪(LDF)在静止、局部温度升高以及使用血管扩张剂烟酸甲酯(MN)的情况下,在六个相互关联的方案中测量牙龈微血管床供血情况的周间重现性。使用定制的丙烯酸夹板进行周间 LDF 测量。在不同的感兴趣区(ROI)采用了六种方案:1;基础 LDF;2;42 °C热探针 LDF;3;45 °C热探针 LDF;4;42 °C热探针和 MN LDF;5;45 °C热探针和 MN LDF;6;MN LDF。结果个体间的可重复性通过受试者内变异系数(wCV)和类内相关系数(ICC)进行评估。基础 LDF 测量的重现性很高,2 分钟内 wCV 为 11.1,5 分钟内为 10.3。加热和 MN 后的 wCV 为 4.9-10.3,ICC 为 0.82-0.93。这是对牙龈基础 LDF 与单次或多次血管扩张刺激相比的可重复性进行评估的首次研究。建议使用多个集束纤维探针和稳定丙烯酸夹板。血管扩张刺激显示出更高的可重复性。此外,MN 可使牙龈血管扩张。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols

Objectives

Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva.

Methods

Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 °C, 3; LDF with thermoprobe 45 °C, 4; LDF with thermoprobe 42 °C and MN, 5; LDF with thermoprobe 45 °C and MN and 6; LDF with MN.

Results

Intra-individual reproducibility was assessed by the within-subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9–10.3 and ICC 0.82–0.93. The topically applied MN yielded increased blood flow.

Conclusion

This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microvascular research
Microvascular research 医学-外周血管病
CiteScore
6.00
自引率
3.20%
发文量
158
审稿时长
43 days
期刊介绍: Microvascular Research is dedicated to the dissemination of fundamental information related to the microvascular field. Full-length articles presenting the results of original research and brief communications are featured. Research Areas include: • Angiogenesis • Biochemistry • Bioengineering • Biomathematics • Biophysics • Cancer • Circulatory homeostasis • Comparative physiology • Drug delivery • Neuropharmacology • Microvascular pathology • Rheology • Tissue Engineering.
期刊最新文献
Editorial Board Functional heterogeneity of endothelium-dependent vasorelaxation in different order branches of mesenteric artery in female/male mice. Pulse wave analysis as a tool to assess endothelial function following lipid lowering intervention in hypercholesterolemia Retinal vascular alterations are associated with cognitive function and neuroimaging in white matter hyperintensities Cardioprotective effects of l-glutamine in an ischemic rat heart model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1