{"title":"绿色合成银纳米粒子涂层钛微型植入物与无涂层微型植入物的毒性评估:动物模型研究中的比较。","authors":"Swapna Sreenivasagan, Aravind Kumar Subramanian, Karthik Ganesh Mohanraj, Rajesh S Kumar","doi":"10.5005/jp-journals-10024-3577","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To assess the potential for systemic toxicity when silver nanoparticle-coated mini-implants were implanted in Wistar albino rats conducted as a comparative study in the animal model by assessing the blood biochemistry, liver and kidney function, and histology of the implanted site.</p><p><strong>Materials and methods: </strong>The surface of the mini-implant was coated with a green-mediated silver nanoparticle. Uncoated mini-implants were placed in two groups of eight Wistar albino rats, and silver nanoparticle-coated mini-implants were placed in another eight rats. The bone's general conditions, blood biochemistry assessing for ALT, AST, GPT, GOT, and histological sections using H and E stain and Masson's Trichrome stain were examined at 7, 14, and 28-day intervals.</p><p><strong>Results: </strong>The creatinine, urea, ALP, and ALT showed no signs of systemic toxicity during the 28-day follow-up period in the Wistar rats both in the test and control groups. The histological evaluation, which was conducted using HE and MTS stain, revealed osteogenesis and adequate healing of the insertion site in the group where coated mini-implant was placed. The bone sample revealed no abnormalities in the control group with uncoated mini-implants.</p><p><strong>Conclusion: </strong>Green synthesized silver nanoparticle-coated mini-implant does not cause systemic toxicity as indicated by no abnormalities in the levels of creatinine, urea, ALT, ALP, GPT, and GOT. The bone histology indicates that the coated mini-implants placed in animal bone healed with adequate osteogenesis.</p><p><strong>Clinical significance: </strong>Silver nanoparticles have potential for antimicrobial activity. Mini-implants placed as temporary anchorage devices in orthodontics often fail due to inflammation and plaque. Silver nanoparticle-coated mini-implants would reduce the risk of mini-implant failure as it would have antimicrobial potential and eliminate this cause for failure of mini-implants. How to cite this article: Sreenivasagan S, Subramanian AK, Mohanraj KG, <i>et al</i>. Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study. J Contemp Dent Pract 2023;24(12):944-950.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study.\",\"authors\":\"Swapna Sreenivasagan, Aravind Kumar Subramanian, Karthik Ganesh Mohanraj, Rajesh S Kumar\",\"doi\":\"10.5005/jp-journals-10024-3577\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To assess the potential for systemic toxicity when silver nanoparticle-coated mini-implants were implanted in Wistar albino rats conducted as a comparative study in the animal model by assessing the blood biochemistry, liver and kidney function, and histology of the implanted site.</p><p><strong>Materials and methods: </strong>The surface of the mini-implant was coated with a green-mediated silver nanoparticle. Uncoated mini-implants were placed in two groups of eight Wistar albino rats, and silver nanoparticle-coated mini-implants were placed in another eight rats. The bone's general conditions, blood biochemistry assessing for ALT, AST, GPT, GOT, and histological sections using H and E stain and Masson's Trichrome stain were examined at 7, 14, and 28-day intervals.</p><p><strong>Results: </strong>The creatinine, urea, ALP, and ALT showed no signs of systemic toxicity during the 28-day follow-up period in the Wistar rats both in the test and control groups. The histological evaluation, which was conducted using HE and MTS stain, revealed osteogenesis and adequate healing of the insertion site in the group where coated mini-implant was placed. The bone sample revealed no abnormalities in the control group with uncoated mini-implants.</p><p><strong>Conclusion: </strong>Green synthesized silver nanoparticle-coated mini-implant does not cause systemic toxicity as indicated by no abnormalities in the levels of creatinine, urea, ALT, ALP, GPT, and GOT. The bone histology indicates that the coated mini-implants placed in animal bone healed with adequate osteogenesis.</p><p><strong>Clinical significance: </strong>Silver nanoparticles have potential for antimicrobial activity. Mini-implants placed as temporary anchorage devices in orthodontics often fail due to inflammation and plaque. Silver nanoparticle-coated mini-implants would reduce the risk of mini-implant failure as it would have antimicrobial potential and eliminate this cause for failure of mini-implants. How to cite this article: Sreenivasagan S, Subramanian AK, Mohanraj KG, <i>et al</i>. Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study. J Contemp Dent Pract 2023;24(12):944-950.</p>\",\"PeriodicalId\":35792,\"journal\":{\"name\":\"Journal of Contemporary Dental Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Contemporary Dental Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10024-3577\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3577","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:作为一项动物模型比较研究,通过评估血液生化、肝肾功能和植入部位的组织学,评估银纳米粒子涂层微型植入体植入 Wistar 白化大鼠体内可能产生的全身毒性:微型植入体表面涂有绿色介导的银纳米粒子。在两组 8 只 Wistar 白化大鼠中植入未涂层的微型植入体,在另外 8 只大鼠中植入银纳米粒子涂层的微型植入体。每隔 7 天、14 天和 28 天对大鼠骨骼的一般状况、血液生化指标(ALT、AST、GPT、GOT)以及组织学切片(H 和 E 染色和 Masson 三色染色)进行检查:结果:在 28 天的随访期间,试验组和对照组 Wistar 大鼠的肌酐、尿素、谷丙转氨酶和谷草转氨酶均未显示出系统毒性迹象。使用 HE 和 MTS 染色法进行的组织学评估显示,在植入涂层微型种植体的组中,插入部位的骨生成和愈合充分。未涂层微型种植体对照组的骨样本未发现异常:结论:绿色合成银纳米粒子涂层微型种植体不会引起全身中毒,肌酐、尿素、谷丙转氨酶、谷草转氨酶、谷丙转氨酶和谷草转氨酶水平均未出现异常。骨组织学表明,将涂层微型植入物植入动物骨骼后,其骨质充分愈合:临床意义:银纳米粒子具有潜在的抗菌活性。在牙齿矫正过程中,作为临时固定装置的微型植入体往往会因炎症和菌斑而失效。纳米银涂层微型种植体具有抗菌潜力,可降低微型种植体失败的风险,消除微型种植体失败的原因。本文引用方式Sreenivasagan S, Subramanian AK, Mohanraj KG, et al. Green Synthesized Silver Nanoparticle coated Titanium Mini-implants with Uncoated Mini-implants 的毒性评估:动物模型研究中的比较。J Contemp Dent Pract 2023;24(12):944-950.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study.

Aim: To assess the potential for systemic toxicity when silver nanoparticle-coated mini-implants were implanted in Wistar albino rats conducted as a comparative study in the animal model by assessing the blood biochemistry, liver and kidney function, and histology of the implanted site.

Materials and methods: The surface of the mini-implant was coated with a green-mediated silver nanoparticle. Uncoated mini-implants were placed in two groups of eight Wistar albino rats, and silver nanoparticle-coated mini-implants were placed in another eight rats. The bone's general conditions, blood biochemistry assessing for ALT, AST, GPT, GOT, and histological sections using H and E stain and Masson's Trichrome stain were examined at 7, 14, and 28-day intervals.

Results: The creatinine, urea, ALP, and ALT showed no signs of systemic toxicity during the 28-day follow-up period in the Wistar rats both in the test and control groups. The histological evaluation, which was conducted using HE and MTS stain, revealed osteogenesis and adequate healing of the insertion site in the group where coated mini-implant was placed. The bone sample revealed no abnormalities in the control group with uncoated mini-implants.

Conclusion: Green synthesized silver nanoparticle-coated mini-implant does not cause systemic toxicity as indicated by no abnormalities in the levels of creatinine, urea, ALT, ALP, GPT, and GOT. The bone histology indicates that the coated mini-implants placed in animal bone healed with adequate osteogenesis.

Clinical significance: Silver nanoparticles have potential for antimicrobial activity. Mini-implants placed as temporary anchorage devices in orthodontics often fail due to inflammation and plaque. Silver nanoparticle-coated mini-implants would reduce the risk of mini-implant failure as it would have antimicrobial potential and eliminate this cause for failure of mini-implants. How to cite this article: Sreenivasagan S, Subramanian AK, Mohanraj KG, et al. Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study. J Contemp Dent Pract 2023;24(12):944-950.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Contemporary Dental Practice
Journal of Contemporary Dental Practice Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
174
期刊介绍: The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.
期刊最新文献
Bibliometric Analysis of Botulinum Toxin and Bruxism: Impact, Visualization, and Collaborative Networks. Comparative Evaluation of Antimicrobial Efficacy of Silver Nanoparticles Infused with Azadirachta indica Extract and Chlorhexidine Against Red-complex Pathogens. Comparative Evaluation of Platelet-rich Fibrin and Treated Dentin Matrix in Regenerative Endodontic Treatment of Nonvital Immature Permanent Teeth: A Randomized Clinical Trial. Comparison of Direct Intraoral Scan and Traditional Impression for CAD/CAM Mandibular Overdenture Base: RCT on Peri-implant Marginal Bone Changes. Comparison of Khoury's Bone Shell Technique vs Titanium-reinforced Polytetrafluoroethylene Membrane for 3D-bone Augmentation in Atrophic Posterior Mandible: A Randomized Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1