Georg C Feuerriegel, Sophia S Goller, Constantin von Deuster, Reto Sutter
{"title":"炎性膝关节滑膜炎:加速 FLAIR 序列与标准对比增强成像的比较评估","authors":"Georg C Feuerriegel, Sophia S Goller, Constantin von Deuster, Reto Sutter","doi":"10.1097/RLI.0000000000001065","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to assess the diagnostic value and accuracy of a deep learning (DL)-accelerated fluid attenuated inversion recovery (FLAIR) sequence with fat saturation (FS) in patients with inflammatory synovitis of the knee.</p><p><strong>Materials and methods: </strong>Patients with suspected knee synovitis were retrospectively included between January and September 2023. All patients underwent a 3 T knee magnetic resonance imaging including a DL-accelerated noncontrast FLAIR FS sequence (acquisition time: 1 minute 38 seconds) and a contrast-enhanced (CE) T1-weighted FS sequence (acquisition time: 4 minutes 50 seconds), which served as reference standard. All knees were scored by 2 radiologists using the semiquantitative modified knee synovitis score, effusion synovitis score, and Hoffa inflammation score. Diagnostic confidence, image quality, and image artifacts were rated on separate Likert scales. Wilcoxon signed rank test was used to compare the semiquantitative scores. Interreader and intrareader reproducibility were calculated using Cohen κ.</p><p><strong>Results: </strong>Fifty-five patients (mean age, 52 ± 17 years; 28 females) were included in the study. Twenty-seven patients (49%) had mild to moderate synovitis (synovitis score 6-13), and 17 patients (31%) had severe synovitis (synovitis score >14). No signs of synovitis were detected in 11 patients (20%) (synovitis score <5). Semiquantitative assessment of the whole knee synovitis score showed no significant difference between the DL-accelerated FLAIR sequence and the CE T1-weighted sequence (mean FLAIR score: 10.69 ± 8.83, T1 turbo spin-echo FS: 10.74 ± 10.32; P = 0.521). Both interreader and intrareader reproducibility were excellent (range Cohen κ [0.82-0.96]).</p><p><strong>Conclusions: </strong>Assessment of inflammatory knee synovitis using a DL-accelerated noncontrast FLAIR FS sequence was feasible and equivalent to CE T1-weighted FS imaging.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":"599-604"},"PeriodicalIF":7.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inflammatory Knee Synovitis: Evaluation of an Accelerated FLAIR Sequence Compared With Standard Contrast-Enhanced Imaging.\",\"authors\":\"Georg C Feuerriegel, Sophia S Goller, Constantin von Deuster, Reto Sutter\",\"doi\":\"10.1097/RLI.0000000000001065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of this study was to assess the diagnostic value and accuracy of a deep learning (DL)-accelerated fluid attenuated inversion recovery (FLAIR) sequence with fat saturation (FS) in patients with inflammatory synovitis of the knee.</p><p><strong>Materials and methods: </strong>Patients with suspected knee synovitis were retrospectively included between January and September 2023. All patients underwent a 3 T knee magnetic resonance imaging including a DL-accelerated noncontrast FLAIR FS sequence (acquisition time: 1 minute 38 seconds) and a contrast-enhanced (CE) T1-weighted FS sequence (acquisition time: 4 minutes 50 seconds), which served as reference standard. All knees were scored by 2 radiologists using the semiquantitative modified knee synovitis score, effusion synovitis score, and Hoffa inflammation score. Diagnostic confidence, image quality, and image artifacts were rated on separate Likert scales. Wilcoxon signed rank test was used to compare the semiquantitative scores. Interreader and intrareader reproducibility were calculated using Cohen κ.</p><p><strong>Results: </strong>Fifty-five patients (mean age, 52 ± 17 years; 28 females) were included in the study. Twenty-seven patients (49%) had mild to moderate synovitis (synovitis score 6-13), and 17 patients (31%) had severe synovitis (synovitis score >14). No signs of synovitis were detected in 11 patients (20%) (synovitis score <5). Semiquantitative assessment of the whole knee synovitis score showed no significant difference between the DL-accelerated FLAIR sequence and the CE T1-weighted sequence (mean FLAIR score: 10.69 ± 8.83, T1 turbo spin-echo FS: 10.74 ± 10.32; P = 0.521). Both interreader and intrareader reproducibility were excellent (range Cohen κ [0.82-0.96]).</p><p><strong>Conclusions: </strong>Assessment of inflammatory knee synovitis using a DL-accelerated noncontrast FLAIR FS sequence was feasible and equivalent to CE T1-weighted FS imaging.</p>\",\"PeriodicalId\":14486,\"journal\":{\"name\":\"Investigative Radiology\",\"volume\":\" \",\"pages\":\"599-604\"},\"PeriodicalIF\":7.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Investigative Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RLI.0000000000001065\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001065","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Inflammatory Knee Synovitis: Evaluation of an Accelerated FLAIR Sequence Compared With Standard Contrast-Enhanced Imaging.
Objectives: The aim of this study was to assess the diagnostic value and accuracy of a deep learning (DL)-accelerated fluid attenuated inversion recovery (FLAIR) sequence with fat saturation (FS) in patients with inflammatory synovitis of the knee.
Materials and methods: Patients with suspected knee synovitis were retrospectively included between January and September 2023. All patients underwent a 3 T knee magnetic resonance imaging including a DL-accelerated noncontrast FLAIR FS sequence (acquisition time: 1 minute 38 seconds) and a contrast-enhanced (CE) T1-weighted FS sequence (acquisition time: 4 minutes 50 seconds), which served as reference standard. All knees were scored by 2 radiologists using the semiquantitative modified knee synovitis score, effusion synovitis score, and Hoffa inflammation score. Diagnostic confidence, image quality, and image artifacts were rated on separate Likert scales. Wilcoxon signed rank test was used to compare the semiquantitative scores. Interreader and intrareader reproducibility were calculated using Cohen κ.
Results: Fifty-five patients (mean age, 52 ± 17 years; 28 females) were included in the study. Twenty-seven patients (49%) had mild to moderate synovitis (synovitis score 6-13), and 17 patients (31%) had severe synovitis (synovitis score >14). No signs of synovitis were detected in 11 patients (20%) (synovitis score <5). Semiquantitative assessment of the whole knee synovitis score showed no significant difference between the DL-accelerated FLAIR sequence and the CE T1-weighted sequence (mean FLAIR score: 10.69 ± 8.83, T1 turbo spin-echo FS: 10.74 ± 10.32; P = 0.521). Both interreader and intrareader reproducibility were excellent (range Cohen κ [0.82-0.96]).
Conclusions: Assessment of inflammatory knee synovitis using a DL-accelerated noncontrast FLAIR FS sequence was feasible and equivalent to CE T1-weighted FS imaging.
期刊介绍:
Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.