比较纤维扫描、剪切波弹性成像和剪切波频散测量在评估肝活检患者纤维化和坏死性炎症中的应用

IF 0.7 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Ultrasound Quarterly Pub Date : 2024-03-01 DOI:10.1097/RUQ.0000000000000677
Sinan Seyrek, Hakan Ayyildiz, Mesut Bulakci, Artur Salmaslioglu, Fatmatuzzehra Seyrek, Burak Gultekin, Bilger Cavus, Neslihan Berker, Melek Buyuk, Servet Yuce
{"title":"比较纤维扫描、剪切波弹性成像和剪切波频散测量在评估肝活检患者纤维化和坏死性炎症中的应用","authors":"Sinan Seyrek, Hakan Ayyildiz, Mesut Bulakci, Artur Salmaslioglu, Fatmatuzzehra Seyrek, Burak Gultekin, Bilger Cavus, Neslihan Berker, Melek Buyuk, Servet Yuce","doi":"10.1097/RUQ.0000000000000677","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).</p><p><strong>Materials and methods: </strong>In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.</p><p><strong>Results: </strong>Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).</p><p><strong>Conclusions: </strong>Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.\",\"authors\":\"Sinan Seyrek, Hakan Ayyildiz, Mesut Bulakci, Artur Salmaslioglu, Fatmatuzzehra Seyrek, Burak Gultekin, Bilger Cavus, Neslihan Berker, Melek Buyuk, Servet Yuce\",\"doi\":\"10.1097/RUQ.0000000000000677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).</p><p><strong>Materials and methods: </strong>In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.</p><p><strong>Results: </strong>Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).</p><p><strong>Conclusions: </strong>Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.</p>\",\"PeriodicalId\":49116,\"journal\":{\"name\":\"Ultrasound Quarterly\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Quarterly\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RUQ.0000000000000677\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000677","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们的目的是利用二维剪切波弹性成像(2D-SWE)、瞬态弹性成像(Fibroscan,TE)和剪切波频散(SWD)的测量结果预测肝纤维化和坏死性炎症的这些阶段:在这项前瞻性设计的研究中,纳入了非特异性病因的慢性肝病患者,他们的活检时间最长为 1 周。进行了二维 SWE、SWD 和 TE 测量。组织病理学评估采用 METAVIR 和 F-ISHAK 分类:结果:二维 SWE 和 TE 被认为对检测肝纤维化具有重要意义。在区分≥F2时,二维SWE的接收者操作特征下面积(AUROC)为0.86(置信区间[CI],0.75-0.96),临界值为8.05 kPa(P = 0.003);TE的接收者操作特征下面积(AUROC)为0.79(置信区间[CI],0.65-0.94),临界值为10.4 kPa(P < 0.001)。TE在区分≥F3方面无显著性差异(P = 0.132)。然而,对于 2D-SWE 而言,≥F3 的临界值为 10.45 kPa(P < 0.001),AUROC = 0.87(CI,0.78-0.97)。剪切波频散度能确定是否存在坏死性炎症(P = 0.016),计算得出≥A2 的临界值为 15.25(米/秒)/千赫兹([米/秒]/千赫兹)(P = 0.006),AUROC 为 0.71(CI,0.57-0.85)。此外,17.25 (m/s)/kHz (P = 0.023) 和 AUROC = 0.72 (CI, 0.51-0.93)的临界值可检测出严重的坏死性炎症。SWD的临界值为15.25 (m/s)/kHz (P = 0.013),用于检测纤维化可逆阶段(F0、F1和F2)的≥A2,AUROC = 0.72 (CI, 0.56-0.88):二维SWE和TE测量在无创检测肝纤维化的不可逆阶段和应治疗阶段方面具有重要意义。剪切波频散测量在无创检测坏死性炎症方面具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.

Objective: Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).

Materials and methods: In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.

Results: Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).

Conclusions: Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound Quarterly
Ultrasound Quarterly RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.50
自引率
7.70%
发文量
105
审稿时长
>12 weeks
期刊介绍: Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography. Official Journal of the Society of Radiologists in Ultrasound
期刊最新文献
Objective Analysis of Predictive Value of Ultrasound Quantitative Scoring System for Treatment Method Selection in Cesarean Scar Pregnancy. Role of Combining Grayscale Findings With Superb Microvascular Imaging and Shear Wave Elastography in Standardization and Management of NON-MASS Breast Lesions. Nonvisualized Ovaries on Ultrasound: Correlation With Surgical Pathology. Reliability of a 2D-Panoramic Ultrasound System for the Determination of Muscle Volume in Older Hospitalized Patients. Pediatric Cranial Ultrasound Revisited: A Comprehensive Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1