Tsutomu Tanno, Akira Hasuike, Koji Naito, Chihiro Ishikura, Akiyoshi Funato
{"title":"利用唇侧牙根扭矩开发正畸种植部位:带 CBCT 分析的病例系列。","authors":"Tsutomu Tanno, Akira Hasuike, Koji Naito, Chihiro Ishikura, Akiyoshi Funato","doi":"10.11607/prd.7094","DOIUrl":null,"url":null,"abstract":"<p><p>This case series assessed the efficacy of Orthodontic Implant Site Development with Labial Root Torque (OISD-LRT) as a nonsurgical technique for addressing labial bone deficiencies in seven patients. The procedure involved strategically placing a multi-bracket of 2-3 mm apically on the hopeless teeth, gradually shifting them with Ni-Ti wires at the rate of 2 mm per month and maintaining overcorrection for 2 months before extraction. OISD-LRT consistently augmented tissue for flapless guided implant surgery, with an average treatment duration of 404Å}311.7 days. Cone-beam computed tomography (CBCT) scans at various stages revealed increases in both vertical and horizontal bone dimensions, especially in the sockets with complete labial bone loss. Despite inevitable post-extraction reductions in bone height and width, sufficient dimensions were maintained to ensure long-term implant stability. This case series highlights the effectiveness of OISD-LRT as a valuable method for horizontal bone augmentation, particularly in patients with labial bone deficiency. This approach provides a robust foundation for subsequent implant placement, showcasing its success in addressing challenging anatomical conditions and contributing to the broader field of implant dentistry.</p>","PeriodicalId":94231,"journal":{"name":"The International journal of periodontics & restorative dentistry","volume":"0 0","pages":"1-18"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Orthodontic Implant Site Development Using Labial Root Torque: A Case Series with CBCT Analysis.\",\"authors\":\"Tsutomu Tanno, Akira Hasuike, Koji Naito, Chihiro Ishikura, Akiyoshi Funato\",\"doi\":\"10.11607/prd.7094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This case series assessed the efficacy of Orthodontic Implant Site Development with Labial Root Torque (OISD-LRT) as a nonsurgical technique for addressing labial bone deficiencies in seven patients. The procedure involved strategically placing a multi-bracket of 2-3 mm apically on the hopeless teeth, gradually shifting them with Ni-Ti wires at the rate of 2 mm per month and maintaining overcorrection for 2 months before extraction. OISD-LRT consistently augmented tissue for flapless guided implant surgery, with an average treatment duration of 404Å}311.7 days. Cone-beam computed tomography (CBCT) scans at various stages revealed increases in both vertical and horizontal bone dimensions, especially in the sockets with complete labial bone loss. Despite inevitable post-extraction reductions in bone height and width, sufficient dimensions were maintained to ensure long-term implant stability. This case series highlights the effectiveness of OISD-LRT as a valuable method for horizontal bone augmentation, particularly in patients with labial bone deficiency. This approach provides a robust foundation for subsequent implant placement, showcasing its success in addressing challenging anatomical conditions and contributing to the broader field of implant dentistry.</p>\",\"PeriodicalId\":94231,\"journal\":{\"name\":\"The International journal of periodontics & restorative dentistry\",\"volume\":\"0 0\",\"pages\":\"1-18\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of periodontics & restorative dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/prd.7094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of periodontics & restorative dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/prd.7094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Orthodontic Implant Site Development Using Labial Root Torque: A Case Series with CBCT Analysis.
This case series assessed the efficacy of Orthodontic Implant Site Development with Labial Root Torque (OISD-LRT) as a nonsurgical technique for addressing labial bone deficiencies in seven patients. The procedure involved strategically placing a multi-bracket of 2-3 mm apically on the hopeless teeth, gradually shifting them with Ni-Ti wires at the rate of 2 mm per month and maintaining overcorrection for 2 months before extraction. OISD-LRT consistently augmented tissue for flapless guided implant surgery, with an average treatment duration of 404Å}311.7 days. Cone-beam computed tomography (CBCT) scans at various stages revealed increases in both vertical and horizontal bone dimensions, especially in the sockets with complete labial bone loss. Despite inevitable post-extraction reductions in bone height and width, sufficient dimensions were maintained to ensure long-term implant stability. This case series highlights the effectiveness of OISD-LRT as a valuable method for horizontal bone augmentation, particularly in patients with labial bone deficiency. This approach provides a robust foundation for subsequent implant placement, showcasing its success in addressing challenging anatomical conditions and contributing to the broader field of implant dentistry.