用于改进复杂介质中生物传感的抗污聚合物或肽修饰电化学生物传感器

Survanshu Saxena, Payel Sen, Leyla Soleymani, T. Hoare
{"title":"用于改进复杂介质中生物传感的抗污聚合物或肽修饰电化学生物传感器","authors":"Survanshu Saxena, Payel Sen, Leyla Soleymani, T. Hoare","doi":"10.1002/adsr.202300170","DOIUrl":null,"url":null,"abstract":"Electrochemical biosensing represents a highly effective technology for detecting disease biomarkers given its high sensitivity, low and clinically relevant limit of detection, and cost effectiveness. However, in complex media such as urine, blood, sweat or saliva, biosensing performance can be significantly impacted by electrode biofouling by proteins, cells, lipids, and other matrix components. Such biofouling leads to reduced signal from the target analyte coupled with an elevated background signal, resulting in poor signal‐to‐noise ratios (SNRs), reduced sensitivity, and lower specificity. This comprehensive review describes the design of anti‐fouling polymers and peptides as a potential solution to prevent or suppress electrochemical biosensor fouling. Various anti‐fouling polymers and peptides developed for improved biosensing in complex media are summarized in the context of their mechanism(s) of anti‐fouling, methods of deposition, and practical applications. Recent advances and persistent challenges in the field are also reviewed to provide perspectives on new directions toward enhancing anti‐fouling in electrochemical biosensors.","PeriodicalId":100037,"journal":{"name":"Advanced Sensor Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Anti‐Fouling Polymer or Peptide‐Modified Electrochemical Biosensors for Improved Biosensing in Complex Media\",\"authors\":\"Survanshu Saxena, Payel Sen, Leyla Soleymani, T. Hoare\",\"doi\":\"10.1002/adsr.202300170\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrochemical biosensing represents a highly effective technology for detecting disease biomarkers given its high sensitivity, low and clinically relevant limit of detection, and cost effectiveness. However, in complex media such as urine, blood, sweat or saliva, biosensing performance can be significantly impacted by electrode biofouling by proteins, cells, lipids, and other matrix components. Such biofouling leads to reduced signal from the target analyte coupled with an elevated background signal, resulting in poor signal‐to‐noise ratios (SNRs), reduced sensitivity, and lower specificity. This comprehensive review describes the design of anti‐fouling polymers and peptides as a potential solution to prevent or suppress electrochemical biosensor fouling. Various anti‐fouling polymers and peptides developed for improved biosensing in complex media are summarized in the context of their mechanism(s) of anti‐fouling, methods of deposition, and practical applications. Recent advances and persistent challenges in the field are also reviewed to provide perspectives on new directions toward enhancing anti‐fouling in electrochemical biosensors.\",\"PeriodicalId\":100037,\"journal\":{\"name\":\"Advanced Sensor Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Sensor Research\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.1002/adsr.202300170\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Sensor Research","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.1002/adsr.202300170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电化学生物传感技术具有灵敏度高、检出限低且与临床相关以及成本效益高等优点,是检测疾病生物标志物的高效技术。然而,在尿液、血液、汗液或唾液等复杂介质中,蛋白质、细胞、脂质和其他基质成分造成的电极生物污染会严重影响生物传感性能。这种生物污染会导致目标分析物的信号降低,同时背景信号升高,从而导致信噪比 (SNR) 变差、灵敏度降低和特异性降低。本综述介绍了防污聚合物和多肽的设计,它们是防止或抑制电化学生物传感器污垢的潜在解决方案。文章从防污机理、沉积方法和实际应用等方面概述了为改善复杂介质中的生物传感而开发的各种防污聚合物和多肽。此外,还回顾了该领域的最新进展和长期挑战,为加强电化学生物传感器的抗污能力提供了新的视角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Anti‐Fouling Polymer or Peptide‐Modified Electrochemical Biosensors for Improved Biosensing in Complex Media
Electrochemical biosensing represents a highly effective technology for detecting disease biomarkers given its high sensitivity, low and clinically relevant limit of detection, and cost effectiveness. However, in complex media such as urine, blood, sweat or saliva, biosensing performance can be significantly impacted by electrode biofouling by proteins, cells, lipids, and other matrix components. Such biofouling leads to reduced signal from the target analyte coupled with an elevated background signal, resulting in poor signal‐to‐noise ratios (SNRs), reduced sensitivity, and lower specificity. This comprehensive review describes the design of anti‐fouling polymers and peptides as a potential solution to prevent or suppress electrochemical biosensor fouling. Various anti‐fouling polymers and peptides developed for improved biosensing in complex media are summarized in the context of their mechanism(s) of anti‐fouling, methods of deposition, and practical applications. Recent advances and persistent challenges in the field are also reviewed to provide perspectives on new directions toward enhancing anti‐fouling in electrochemical biosensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Smart Hydrogel Sensors for Health Monitoring and Early Warning (Adv. Sensor Res. 9/2024) Masthead (Adv. Sensor Res. 9/2024) Integrated Microwave Photonic Sensors Based on Microresonators (Adv. Sensor Res. 8/2024) Development of Kirigami-Patterned Stretchable Tactile Sensor Array with Soft Hinges for Highly Sensitive Force Detection (Adv. Sensor Res. 8/2024) Masthead (Adv. Sensor Res. 8/2024)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1