{"title":"使用微型探针对患有动脉导管未闭的小型犬进行经食道超声心动图检查,以确定经导管程序的候选资格、装置选择和程序监测","authors":"S. Wesselowski, A.B. Saunders","doi":"10.1016/j.jvc.2024.02.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Small dogs with patent ductus arteriosus (PDA) may be unable to undergo transesophageal echocardiography (TEE) with traditional probes.</p></div><div><h3>Objectives</h3><p>To report the utility of TEE using a microprobe in dogs weighing less than 4 kg diagnosed with PDA for determination of transcatheter procedural candidacy, device selection, and intraoperative procedural guidance.</p></div><div><h3>Animals</h3><p>Eight dogs weighing less than 4 kg diagnosed with PDA.</p></div><div><h3>Materials and methods</h3><p>All dogs had standard transthoracic echocardiography and microprobe TEE imaging. The quality of TEE images was graded as optimal, adequate, or poor. The ability of TEE to assess PDA anatomy, determine procedural candidacy, provide procedural guidance, detect deployed devices, and assess residual flow was recorded.</p></div><div><h3>Results</h3><p>The median age of included dogs was 6.4 months (range: 3.2–15.7 months) and the median body weight was 2.2 kg (range: 1.4–3.8 kg). Microprobe TEE images were adequate or optimal in all dogs and were integral for guiding procedural candidacy decisions. Transcatheter procedures were not pursued in two dogs based on TEE images. In the other six dogs, TEE procedural guidance was useful during transvenous (n = 5) and transarterial (n = 1) PDA occlusion attempts. Each deployed device (n = 4) was easily detected with the TEE microprobe. Real-time confirmation of adequate device sizing and placement was possible prior to release and residual flow could be monitored after release.</p></div><div><h3>Conclusions</h3><p>Transesophageal echocardiography using a microprobe in dogs weighing less than 4 kg diagnosed with PDA allowed for characterization of PDA anatomy and determination of transcatheter procedural candidacy. Microprobe TEE images were integral for PDA device selection and offered valuable intraoperative procedural guidance.</p></div>","PeriodicalId":48788,"journal":{"name":"Journal of Veterinary Cardiology","volume":"52 ","pages":"Pages 35-42"},"PeriodicalIF":1.5000,"publicationDate":"2024-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transesophageal echocardiography using a microprobe for determination of transcatheter procedural candidacy, device selection, and procedural monitoring in small dogs with patent ductus arteriosus\",\"authors\":\"S. Wesselowski, A.B. Saunders\",\"doi\":\"10.1016/j.jvc.2024.02.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Small dogs with patent ductus arteriosus (PDA) may be unable to undergo transesophageal echocardiography (TEE) with traditional probes.</p></div><div><h3>Objectives</h3><p>To report the utility of TEE using a microprobe in dogs weighing less than 4 kg diagnosed with PDA for determination of transcatheter procedural candidacy, device selection, and intraoperative procedural guidance.</p></div><div><h3>Animals</h3><p>Eight dogs weighing less than 4 kg diagnosed with PDA.</p></div><div><h3>Materials and methods</h3><p>All dogs had standard transthoracic echocardiography and microprobe TEE imaging. The quality of TEE images was graded as optimal, adequate, or poor. The ability of TEE to assess PDA anatomy, determine procedural candidacy, provide procedural guidance, detect deployed devices, and assess residual flow was recorded.</p></div><div><h3>Results</h3><p>The median age of included dogs was 6.4 months (range: 3.2–15.7 months) and the median body weight was 2.2 kg (range: 1.4–3.8 kg). Microprobe TEE images were adequate or optimal in all dogs and were integral for guiding procedural candidacy decisions. Transcatheter procedures were not pursued in two dogs based on TEE images. In the other six dogs, TEE procedural guidance was useful during transvenous (n = 5) and transarterial (n = 1) PDA occlusion attempts. Each deployed device (n = 4) was easily detected with the TEE microprobe. Real-time confirmation of adequate device sizing and placement was possible prior to release and residual flow could be monitored after release.</p></div><div><h3>Conclusions</h3><p>Transesophageal echocardiography using a microprobe in dogs weighing less than 4 kg diagnosed with PDA allowed for characterization of PDA anatomy and determination of transcatheter procedural candidacy. Microprobe TEE images were integral for PDA device selection and offered valuable intraoperative procedural guidance.</p></div>\",\"PeriodicalId\":48788,\"journal\":{\"name\":\"Journal of Veterinary Cardiology\",\"volume\":\"52 \",\"pages\":\"Pages 35-42\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-02-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Veterinary Cardiology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1760273424000109\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Cardiology","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1760273424000109","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
目的 报告使用微探针对体重小于 4 千克、诊断为 PDA 的犬进行经食道超声心动图检查的实用性,以确定经导管手术的候选资格、设备选择和术中手术指导。TEE 图像的质量分为最佳、足够和较差。记录了 TEE 评估 PDA 解剖学、确定程序候选资格、提供程序指导、检测已部署的装置和评估残余血流的能力。结果纳入犬的中位年龄为 6.4 个月(范围:3.2-15.7 个月),中位体重为 2.2 千克(范围:1.4-3.8 千克)。所有病犬的微探针 TEE 图像均达到或达到最佳水平,对指导手术候选决定至关重要。根据 TEE 图像,有两只狗没有接受经导管手术。另外六只狗在尝试经静脉(5 只)和经动脉(1 只)PDA 闭塞时,TEE 程序指导非常有用。使用 TEE 微型探针很容易检测到每个已部署的装置(n = 4)。结论使用微探针对体重小于 4 千克的 PDA 诊断犬进行经食道超声心动图检查,可确定 PDA 解剖学特征并确定是否适合经导管手术。微探头超声心动图图像是选择 PDA 装置的必要条件,并为术中程序提供了宝贵的指导。
Transesophageal echocardiography using a microprobe for determination of transcatheter procedural candidacy, device selection, and procedural monitoring in small dogs with patent ductus arteriosus
Introduction
Small dogs with patent ductus arteriosus (PDA) may be unable to undergo transesophageal echocardiography (TEE) with traditional probes.
Objectives
To report the utility of TEE using a microprobe in dogs weighing less than 4 kg diagnosed with PDA for determination of transcatheter procedural candidacy, device selection, and intraoperative procedural guidance.
Animals
Eight dogs weighing less than 4 kg diagnosed with PDA.
Materials and methods
All dogs had standard transthoracic echocardiography and microprobe TEE imaging. The quality of TEE images was graded as optimal, adequate, or poor. The ability of TEE to assess PDA anatomy, determine procedural candidacy, provide procedural guidance, detect deployed devices, and assess residual flow was recorded.
Results
The median age of included dogs was 6.4 months (range: 3.2–15.7 months) and the median body weight was 2.2 kg (range: 1.4–3.8 kg). Microprobe TEE images were adequate or optimal in all dogs and were integral for guiding procedural candidacy decisions. Transcatheter procedures were not pursued in two dogs based on TEE images. In the other six dogs, TEE procedural guidance was useful during transvenous (n = 5) and transarterial (n = 1) PDA occlusion attempts. Each deployed device (n = 4) was easily detected with the TEE microprobe. Real-time confirmation of adequate device sizing and placement was possible prior to release and residual flow could be monitored after release.
Conclusions
Transesophageal echocardiography using a microprobe in dogs weighing less than 4 kg diagnosed with PDA allowed for characterization of PDA anatomy and determination of transcatheter procedural candidacy. Microprobe TEE images were integral for PDA device selection and offered valuable intraoperative procedural guidance.
期刊介绍:
The mission of the Journal of Veterinary Cardiology is to publish peer-reviewed reports of the highest quality that promote greater understanding of cardiovascular disease, and enhance the health and well being of animals and humans. The Journal of Veterinary Cardiology publishes original contributions involving research and clinical practice that include prospective and retrospective studies, clinical trials, epidemiology, observational studies, and advances in applied and basic research.
The Journal invites submission of original manuscripts. Specific content areas of interest include heart failure, arrhythmias, congenital heart disease, cardiovascular medicine, surgery, hypertension, health outcomes research, diagnostic imaging, interventional techniques, genetics, molecular cardiology, and cardiovascular pathology, pharmacology, and toxicology.