{"title":"为资源贫乏环境开发本地制造的多元件超声波成像传感器。","authors":"A.J. Wilson ,&nbsp;R.W. Taylor ,&nbsp;S.E. Burrows ,&nbsp;S.M. Dixon","doi":"10.1016/j.ipemt.2024.100023","DOIUrl":null,"url":null,"abstract":"<div><p>This paper investigates techniques and materials for making a multi-element ultrasound imaging transducer with craft-based techniques available in resource poor environments. The transducer housing can be conveniently divided into three parts: the body supporting the piezoelectric (PZT) elements and other components; the matching layer between the PZT elements and the human body; and the backing layer behind the PZT elements. Low-cost 3D printing systems based on photopolymers were found to be suitable for manufacturing the body. Finite Element Modelling (FEM) showed that the material characteristics of the backing layer and the thickness of the matching layer were much less critical than predicted by ultrasound plane wave theory and transmission line theory, respectively. The backing and matching layers are normally made from epoxy-tungsten composites that are pourable in the uncured state. However, the composite required for the backing layer was putty-like when uncured. When the tungsten was allowed to settle under gravity during curing, a 20 % by volume uncured tungsten-epoxy composite gave a 30 % by volume concentration of tungsten at the bottom when cured at 20–30 °C. These findings, when coupled with the findings from the FEM modelling, suggests that constructing a multi-element ultrasound imaging transducer using craft-based techniques is feasible.</p></div>","PeriodicalId":73507,"journal":{"name":"IPEM-translation","volume":"9 ","pages":"Article 100023"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667258824000013/pdfft?md5=2a3b6a3d10cb4d9ed4c4f796bcfba694&pid=1-s2.0-S2667258824000013-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Towards a locally constructed multi-element ultrasound imaging transducer for resource poor environments\",\"authors\":\"A.J. Wilson ,&nbsp;R.W. Taylor ,&nbsp;S.E. Burrows ,&nbsp;S.M. Dixon\",\"doi\":\"10.1016/j.ipemt.2024.100023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This paper investigates techniques and materials for making a multi-element ultrasound imaging transducer with craft-based techniques available in resource poor environments. The transducer housing can be conveniently divided into three parts: the body supporting the piezoelectric (PZT) elements and other components; the matching layer between the PZT elements and the human body; and the backing layer behind the PZT elements. Low-cost 3D printing systems based on photopolymers were found to be suitable for manufacturing the body. Finite Element Modelling (FEM) showed that the material characteristics of the backing layer and the thickness of the matching layer were much less critical than predicted by ultrasound plane wave theory and transmission line theory, respectively. The backing and matching layers are normally made from epoxy-tungsten composites that are pourable in the uncured state. However, the composite required for the backing layer was putty-like when uncured. When the tungsten was allowed to settle under gravity during curing, a 20 % by volume uncured tungsten-epoxy composite gave a 30 % by volume concentration of tungsten at the bottom when cured at 20–30 °C. These findings, when coupled with the findings from the FEM modelling, suggests that constructing a multi-element ultrasound imaging transducer using craft-based techniques is feasible.</p></div>\",\"PeriodicalId\":73507,\"journal\":{\"name\":\"IPEM-translation\",\"volume\":\"9 \",\"pages\":\"Article 100023\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2667258824000013/pdfft?md5=2a3b6a3d10cb4d9ed4c4f796bcfba694&pid=1-s2.0-S2667258824000013-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IPEM-translation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667258824000013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IPEM-translation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667258824000013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了在资源匮乏的环境中利用手工技术制作多元件超声波成像换能器的技术和材料。换能器外壳可方便地分为三部分:支撑压电(PZT)元件和其他组件的主体;PZT元件与人体之间的匹配层;PZT元件后面的支撑层。研究发现,基于光聚合物的低成本三维打印系统适用于制造人体。有限元建模(FEM)显示,背衬层的材料特性和匹配层的厚度分别比超声平面波理论和传输线理论预测的要小得多。背层和匹配层通常由环氧-钨复合材料制成,在未固化状态下可以浇注。然而,背层所需的复合材料在未固化时呈油灰状。如果在固化过程中让钨在重力作用下沉淀,那么在 20-30 °C 的固化温度下,20%(体积)未固化的钨-环氧树脂复合材料底部的钨浓度为 30%(体积)。这些发现加上有限元建模的结果表明,利用基于工艺的技术制造多元件超声波成像传感器是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Towards a locally constructed multi-element ultrasound imaging transducer for resource poor environments

This paper investigates techniques and materials for making a multi-element ultrasound imaging transducer with craft-based techniques available in resource poor environments. The transducer housing can be conveniently divided into three parts: the body supporting the piezoelectric (PZT) elements and other components; the matching layer between the PZT elements and the human body; and the backing layer behind the PZT elements. Low-cost 3D printing systems based on photopolymers were found to be suitable for manufacturing the body. Finite Element Modelling (FEM) showed that the material characteristics of the backing layer and the thickness of the matching layer were much less critical than predicted by ultrasound plane wave theory and transmission line theory, respectively. The backing and matching layers are normally made from epoxy-tungsten composites that are pourable in the uncured state. However, the composite required for the backing layer was putty-like when uncured. When the tungsten was allowed to settle under gravity during curing, a 20 % by volume uncured tungsten-epoxy composite gave a 30 % by volume concentration of tungsten at the bottom when cured at 20–30 °C. These findings, when coupled with the findings from the FEM modelling, suggests that constructing a multi-element ultrasound imaging transducer using craft-based techniques is feasible.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IPEM-translation
IPEM-translation Medicine and Dentistry (General)
自引率
0.00%
发文量
0
审稿时长
63 days
期刊最新文献
National radiotherapy dosimetry audit in the UK – A vision and roadmap A review of the clinical value of mechanical ventilators and extracorporeal membrane oxygenation (ECMO) equipment Experimental measurement of dosimetric parameters relevant to radioactive needlestick injury The use of solar film elements on a neonate manikin surface to estimate the received output power of neonatal phototherapy lamp systems Role of Coriolis flow measurement technology in validation of model of syringe driver performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1