使用稳定性指示高效液相色谱、液相色谱-质谱和高分辨质谱技术分离和定量药物剂型中抗组胺药物羟嗪的有机相关杂质

IF 1.3 Q4 CHEMISTRY, ANALYTICAL SEPARATION SCIENCE PLUS Pub Date : 2024-02-13 DOI:10.1002/sscp.202300157
N. V. V. D. P. Boppy, S. Haridasyam, Niroja Vadagam, M. Venkatanarayana, Sanjeeva R. Chinnakadoori, Dr. Narasimha S. Lakka, PhD
{"title":"使用稳定性指示高效液相色谱、液相色谱-质谱和高分辨质谱技术分离和定量药物剂型中抗组胺药物羟嗪的有机相关杂质","authors":"N. V. V. D. P. Boppy, S. Haridasyam, Niroja Vadagam, M. Venkatanarayana, Sanjeeva R. Chinnakadoori, Dr. Narasimha S. Lakka, PhD","doi":"10.1002/sscp.202300157","DOIUrl":null,"url":null,"abstract":"A simple and robust high‐performance liquid chromatography (HPLC) method was developed for organic impurities of hydroxyzine hydrochloride in pharmaceuticals. The developed method was designed to estimate all organic impurities of hydroxyzine. The HPLC separation was achieved using C18 column (150 × 3.9 mm, 5 μm) along with a binary gradient consisting of mobile phases A (0.1%, trifluoroacetic acid in purified water) and B (0.05%, trifluoroacetic acid in acetonitrile), a flow rate of 0.7–mL/min, a column temperature of 30°C and a sample temperature of 25°C. The detection wavelength used was 230 nm for the estimation of impurity‐A, impurity‐B, and all unspecified impurities and degradation products, whereas impurity‐C was quantitated using 254 nm. The stability‐indicating property of the developed HPLC technique was assessed using stress testing conditions of hydrolysis, oxidation, thermal, photo‐light, and humidity. The validation study was performed for the limit of detection and limit of quantification, linearity, and recoveries were 0.03%, 0.05%, and 0.1132–2.9920 μg/mL (R2 > 0.999), and 84.09%–109.74%, respectively. The proposed method is highly suitable for the determination of assay, organic impurities, and degradation products of the hydroxyzine. The chemical structure of degradation product 1 (hydroxyzine N‐Oxide) and degradation product 2 (O‐Acetyl hydroxyzine) were identified with the supporting data of LC‐mass spectrometry (LC‐MS) and high‐resolution MS.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Separation and quantification of organic‐related impurities of anti‐histamine drug hydroxyzine in pharmaceutical dosage forms using stability‐indicating high‐performance liquid chromatography, liquid chromatography‐mass spectrometry, and high‐resolution mass spectrometry techniques\",\"authors\":\"N. V. V. D. P. Boppy, S. Haridasyam, Niroja Vadagam, M. Venkatanarayana, Sanjeeva R. Chinnakadoori, Dr. Narasimha S. Lakka, PhD\",\"doi\":\"10.1002/sscp.202300157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple and robust high‐performance liquid chromatography (HPLC) method was developed for organic impurities of hydroxyzine hydrochloride in pharmaceuticals. The developed method was designed to estimate all organic impurities of hydroxyzine. The HPLC separation was achieved using C18 column (150 × 3.9 mm, 5 μm) along with a binary gradient consisting of mobile phases A (0.1%, trifluoroacetic acid in purified water) and B (0.05%, trifluoroacetic acid in acetonitrile), a flow rate of 0.7–mL/min, a column temperature of 30°C and a sample temperature of 25°C. The detection wavelength used was 230 nm for the estimation of impurity‐A, impurity‐B, and all unspecified impurities and degradation products, whereas impurity‐C was quantitated using 254 nm. The stability‐indicating property of the developed HPLC technique was assessed using stress testing conditions of hydrolysis, oxidation, thermal, photo‐light, and humidity. The validation study was performed for the limit of detection and limit of quantification, linearity, and recoveries were 0.03%, 0.05%, and 0.1132–2.9920 μg/mL (R2 > 0.999), and 84.09%–109.74%, respectively. The proposed method is highly suitable for the determination of assay, organic impurities, and degradation products of the hydroxyzine. The chemical structure of degradation product 1 (hydroxyzine N‐Oxide) and degradation product 2 (O‐Acetyl hydroxyzine) were identified with the supporting data of LC‐mass spectrometry (LC‐MS) and high‐resolution MS.\",\"PeriodicalId\":21639,\"journal\":{\"name\":\"SEPARATION SCIENCE PLUS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SEPARATION SCIENCE PLUS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/sscp.202300157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

针对药品中盐酸羟嗪的有机杂质,建立了一种简便、稳健的高效液相色谱(HPLC)方法。所建立的方法可用于盐酸羟嗪所有有机杂质的检测。采用C18色谱柱(150×3.9 mm,5 μm),流动相为A(0.1%三氟乙酸溶于纯水)和B(0.05%三氟乙酸溶于乙腈),流速为0.7 mL/min,柱温为30℃,样品温度为25℃。杂质-A、杂质-B 以及所有未指定杂质和降解产物的检测波长为 230 nm,杂质-C 的定量检测波长为 254 nm。在水解、氧化、热、光照和湿度等应力测试条件下,对所开发的高效液相色谱技术的稳定性进行了评估。该方法的检出限、定量限、线性和回收率分别为 0.03%、0.05%、0.1132-2.9920 μg/mL(R2 > 0.999)和 84.09%-109.74%。该方法适用于羟嗪的测定、有机杂质和降解产物的检测。利用液相色谱-质谱和高分辨质谱的支持数据确定了降解产物1(羟嗪N-氧化物)和降解产物2(O-乙酰基羟嗪)的化学结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Separation and quantification of organic‐related impurities of anti‐histamine drug hydroxyzine in pharmaceutical dosage forms using stability‐indicating high‐performance liquid chromatography, liquid chromatography‐mass spectrometry, and high‐resolution mass spectrometry techniques
A simple and robust high‐performance liquid chromatography (HPLC) method was developed for organic impurities of hydroxyzine hydrochloride in pharmaceuticals. The developed method was designed to estimate all organic impurities of hydroxyzine. The HPLC separation was achieved using C18 column (150 × 3.9 mm, 5 μm) along with a binary gradient consisting of mobile phases A (0.1%, trifluoroacetic acid in purified water) and B (0.05%, trifluoroacetic acid in acetonitrile), a flow rate of 0.7–mL/min, a column temperature of 30°C and a sample temperature of 25°C. The detection wavelength used was 230 nm for the estimation of impurity‐A, impurity‐B, and all unspecified impurities and degradation products, whereas impurity‐C was quantitated using 254 nm. The stability‐indicating property of the developed HPLC technique was assessed using stress testing conditions of hydrolysis, oxidation, thermal, photo‐light, and humidity. The validation study was performed for the limit of detection and limit of quantification, linearity, and recoveries were 0.03%, 0.05%, and 0.1132–2.9920 μg/mL (R2 > 0.999), and 84.09%–109.74%, respectively. The proposed method is highly suitable for the determination of assay, organic impurities, and degradation products of the hydroxyzine. The chemical structure of degradation product 1 (hydroxyzine N‐Oxide) and degradation product 2 (O‐Acetyl hydroxyzine) were identified with the supporting data of LC‐mass spectrometry (LC‐MS) and high‐resolution MS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
期刊最新文献
Removal of Residual DNA and Host Cell Proteins for the Purification of Recombinant Staphylokinase Expressed in Escherichia coli Green Analytical Approach for HPLC Method Development for Quantification of Sorafenib and Its Pharmacopeia Impurities: LC–MS/MS Characterization and Toxicity Prediction of Stress Degradation Products A Cartridge Structure Facilitates Clinical Mass Spectrometry Pretreatment and Can be Integrated Into a High‐Throughput Instrument Comparison of Polysaccharide Profiles of Different Seaweeds Based on Ion Chromatography and Ultrahigh‐Performance Liquid Chromatography Quantification of Recycled Polypropylene Stabilizers for Quality Control by Liquid Chromatography–Tandem Mass Spectrometry Using Simple, Fast and Efficient Ultrasonic Extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1