{"title":"用于植入式双相神经刺激器的 3 毫伏精密双模控制快速充电平衡器。","authors":"Kai Cui;Yaxue Jin;Xiaoya Fan;Yanzhao Ma","doi":"10.1109/TBCAS.2024.3366518","DOIUrl":null,"url":null,"abstract":"This paper 5 presents a novel charge balancing (CB) with a current-control (CC) mode and a voltage-control (VC) mode for implantable biphasic stimulators, which can achieve one-step accurate anodic pulse generating. Compared with the conventional short-pulse-injection-based CB, the proposed method could reduce the balancing time and avoid inducing undesired artifact. The CC operation compensates the majority stimulation charge at high speed, while the VC operation guarantees a high CB precision. In order to eliminate the oscillation during the mode transition, a smooth CC-VC transition method is adopted. In addition, a digital auxiliary monitoring loop is introduced against the variations of the tissue-electrode interface impedance during the stimulation process to meet long-term CB requirement. The proposed stimulator has been fabricated in a 0.18 μm BCD process with 10 V voltage compliance, and the measured CB precision is less than 3 mV. The functionalities of the proposed CB have been verified successfully through \n<italic>in vitro</i>\n experiments.","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 3-mV Precision Dual-Mode-Controlled Fast Charge Balancing for Implantable Biphasic Neural Stimulators\",\"authors\":\"Kai Cui;Yaxue Jin;Xiaoya Fan;Yanzhao Ma\",\"doi\":\"10.1109/TBCAS.2024.3366518\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper 5 presents a novel charge balancing (CB) with a current-control (CC) mode and a voltage-control (VC) mode for implantable biphasic stimulators, which can achieve one-step accurate anodic pulse generating. Compared with the conventional short-pulse-injection-based CB, the proposed method could reduce the balancing time and avoid inducing undesired artifact. The CC operation compensates the majority stimulation charge at high speed, while the VC operation guarantees a high CB precision. In order to eliminate the oscillation during the mode transition, a smooth CC-VC transition method is adopted. In addition, a digital auxiliary monitoring loop is introduced against the variations of the tissue-electrode interface impedance during the stimulation process to meet long-term CB requirement. The proposed stimulator has been fabricated in a 0.18 μm BCD process with 10 V voltage compliance, and the measured CB precision is less than 3 mV. The functionalities of the proposed CB have been verified successfully through \\n<italic>in vitro</i>\\n experiments.\",\"PeriodicalId\":94031,\"journal\":{\"name\":\"IEEE transactions on biomedical circuits and systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on biomedical circuits and systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10444610/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10444610/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 3-mV Precision Dual-Mode-Controlled Fast Charge Balancing for Implantable Biphasic Neural Stimulators
This paper 5 presents a novel charge balancing (CB) with a current-control (CC) mode and a voltage-control (VC) mode for implantable biphasic stimulators, which can achieve one-step accurate anodic pulse generating. Compared with the conventional short-pulse-injection-based CB, the proposed method could reduce the balancing time and avoid inducing undesired artifact. The CC operation compensates the majority stimulation charge at high speed, while the VC operation guarantees a high CB precision. In order to eliminate the oscillation during the mode transition, a smooth CC-VC transition method is adopted. In addition, a digital auxiliary monitoring loop is introduced against the variations of the tissue-electrode interface impedance during the stimulation process to meet long-term CB requirement. The proposed stimulator has been fabricated in a 0.18 μm BCD process with 10 V voltage compliance, and the measured CB precision is less than 3 mV. The functionalities of the proposed CB have been verified successfully through
in vitro
experiments.