{"title":"基于热水力学性能参数的挫面粗化太阳能空气加热器实验研究","authors":"Dharam Singh, Vikash Kumar","doi":"10.1177/09576509241227754","DOIUrl":null,"url":null,"abstract":"An outdoor experimental investigation was conducted to explore the thermohydraulic characteristic (Nusselt no. and friction factor) of artificial roughened solar air heater (ARSAH) having frustrum shaped roughened element on absorber plate. Data were recorded and further processed to generate Nusselt number and friction factor correlation to predict the effect of flow and roughness parameter on performance of ARSAH. The investigation was conducted by varying Reynolds number in range of 2500–12,500. Dimensionless parameter for Frustrum shaped roughness was relative frustum height (e/D<jats:sub>h</jats:sub>) from 0.013 to 0.054, relative frustum pitch (p/e) from 8 to 14, Relative frustum height to base diameter (e/d<jats:sub>1</jats:sub>) from 0.37 to 0.75, relative frustum diametral ratio (d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub>) from 1 to 3. Maximum performance for ARSAH was obtained corresponding to the optimum value of flow and geometric parameter. The geometric orientation of the proposed roughness geometry produced tremendous rise in Nu with an acceptable rise in friction (f). Maximum enhancement in Nu for varying p/e, e/D<jats:sub>h</jats:sub>, e/d<jats:sub>1</jats:sub>, and d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub> was, 4.58, 5.21, 6.62 and 6.09 times and that of friction was 5.59, 4.69, 4.92 and 4.66 times respectively over conventional SAH. Maximum Thermohydraulic performance was 3.7, 3.6, 3.9 and 3.8 at p/e = 12, e/D<jats:sub>h</jats:sub> = 0.054, e/d<jats:sub>1</jats:sub> = 0.75 and d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub> = 3.","PeriodicalId":20705,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":"2 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2024-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermohydraulic performance parameter based experimental investigation of frustum shaped roughened solar air heater\",\"authors\":\"Dharam Singh, Vikash Kumar\",\"doi\":\"10.1177/09576509241227754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An outdoor experimental investigation was conducted to explore the thermohydraulic characteristic (Nusselt no. and friction factor) of artificial roughened solar air heater (ARSAH) having frustrum shaped roughened element on absorber plate. Data were recorded and further processed to generate Nusselt number and friction factor correlation to predict the effect of flow and roughness parameter on performance of ARSAH. The investigation was conducted by varying Reynolds number in range of 2500–12,500. Dimensionless parameter for Frustrum shaped roughness was relative frustum height (e/D<jats:sub>h</jats:sub>) from 0.013 to 0.054, relative frustum pitch (p/e) from 8 to 14, Relative frustum height to base diameter (e/d<jats:sub>1</jats:sub>) from 0.37 to 0.75, relative frustum diametral ratio (d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub>) from 1 to 3. Maximum performance for ARSAH was obtained corresponding to the optimum value of flow and geometric parameter. The geometric orientation of the proposed roughness geometry produced tremendous rise in Nu with an acceptable rise in friction (f). Maximum enhancement in Nu for varying p/e, e/D<jats:sub>h</jats:sub>, e/d<jats:sub>1</jats:sub>, and d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub> was, 4.58, 5.21, 6.62 and 6.09 times and that of friction was 5.59, 4.69, 4.92 and 4.66 times respectively over conventional SAH. Maximum Thermohydraulic performance was 3.7, 3.6, 3.9 and 3.8 at p/e = 12, e/D<jats:sub>h</jats:sub> = 0.054, e/d<jats:sub>1</jats:sub> = 0.75 and d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub> = 3.\",\"PeriodicalId\":20705,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-01-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09576509241227754\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09576509241227754","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Thermohydraulic performance parameter based experimental investigation of frustum shaped roughened solar air heater
An outdoor experimental investigation was conducted to explore the thermohydraulic characteristic (Nusselt no. and friction factor) of artificial roughened solar air heater (ARSAH) having frustrum shaped roughened element on absorber plate. Data were recorded and further processed to generate Nusselt number and friction factor correlation to predict the effect of flow and roughness parameter on performance of ARSAH. The investigation was conducted by varying Reynolds number in range of 2500–12,500. Dimensionless parameter for Frustrum shaped roughness was relative frustum height (e/Dh) from 0.013 to 0.054, relative frustum pitch (p/e) from 8 to 14, Relative frustum height to base diameter (e/d1) from 0.37 to 0.75, relative frustum diametral ratio (d1/d2) from 1 to 3. Maximum performance for ARSAH was obtained corresponding to the optimum value of flow and geometric parameter. The geometric orientation of the proposed roughness geometry produced tremendous rise in Nu with an acceptable rise in friction (f). Maximum enhancement in Nu for varying p/e, e/Dh, e/d1, and d1/d2 was, 4.58, 5.21, 6.62 and 6.09 times and that of friction was 5.59, 4.69, 4.92 and 4.66 times respectively over conventional SAH. Maximum Thermohydraulic performance was 3.7, 3.6, 3.9 and 3.8 at p/e = 12, e/Dh = 0.054, e/d1 = 0.75 and d1/d2 = 3.
期刊介绍:
The Journal of Power and Energy, Part A of the Proceedings of the Institution of Mechanical Engineers, is dedicated to publishing peer-reviewed papers of high scientific quality on all aspects of the technology of energy conversion systems.