{"title":"用于片剂盐酸二甲双胍电位测定的丝网印刷微芯片的验证与应用","authors":"Mohammed Alqarni, Abdullah A. Alshehri, Hassan Arida","doi":"10.1155/2024/8664723","DOIUrl":null,"url":null,"abstract":"Metformin is an oral biguanides hypoglycaemic agent, which used to lower the blood glucose levels in people with type 2 diabetes mellitus. Many analytical techniques have been used to quantify the drug in different pharmaceutical dosage forms; however, most of these methods have limited throughput in the quality control application. A disposable potentiometric microsensor responsive to metformin has recently been reported. For the first time, herein, this method of analysis has been validated according to IUPAC recommendations and successfully applied in the determination of metformin drug in some dosage form. Different drug formulations of metformin hydrochloride have been collected from the local pharmaceutical stores in Saudi Arabia and analysed using the validated microchip-based method of analysis. Subsequently, the results of this study showed that the validated method was linear, specific, precise, and accurate. The linear range was 1 × 10<sup>−1</sup>–1 × 10<sup>−5</sup> mol L<sup>−1</sup> and the correlation coefficient was 0.999. The limit of detection was 2.89 × 10<sup>−6</sup> mol L<sup>−1</sup>, and the limit of quantification was 8.77 × 10<sup>−6</sup> mol L<sup>−1</sup>. This method demonstrated high precision, with an RSD% of less than 2.22%. The accuracy of this method was obtained by comparing the recovery percentage with percentage values less than 5%. The results obtained showed that there was no significant difference between the references, label, and recovery of less than 5%.","PeriodicalId":13888,"journal":{"name":"International Journal of Analytical Chemistry","volume":"79 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation and Application of Screen-Printed Microchip for Potentiometric Determination of Metformin Hydrochloride in Tablet Dosage Form\",\"authors\":\"Mohammed Alqarni, Abdullah A. Alshehri, Hassan Arida\",\"doi\":\"10.1155/2024/8664723\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Metformin is an oral biguanides hypoglycaemic agent, which used to lower the blood glucose levels in people with type 2 diabetes mellitus. Many analytical techniques have been used to quantify the drug in different pharmaceutical dosage forms; however, most of these methods have limited throughput in the quality control application. A disposable potentiometric microsensor responsive to metformin has recently been reported. For the first time, herein, this method of analysis has been validated according to IUPAC recommendations and successfully applied in the determination of metformin drug in some dosage form. Different drug formulations of metformin hydrochloride have been collected from the local pharmaceutical stores in Saudi Arabia and analysed using the validated microchip-based method of analysis. Subsequently, the results of this study showed that the validated method was linear, specific, precise, and accurate. The linear range was 1 × 10<sup>−1</sup>–1 × 10<sup>−5</sup> mol L<sup>−1</sup> and the correlation coefficient was 0.999. The limit of detection was 2.89 × 10<sup>−6</sup> mol L<sup>−1</sup>, and the limit of quantification was 8.77 × 10<sup>−6</sup> mol L<sup>−1</sup>. This method demonstrated high precision, with an RSD% of less than 2.22%. The accuracy of this method was obtained by comparing the recovery percentage with percentage values less than 5%. The results obtained showed that there was no significant difference between the references, label, and recovery of less than 5%.\",\"PeriodicalId\":13888,\"journal\":{\"name\":\"International Journal of Analytical Chemistry\",\"volume\":\"79 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/8664723\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2024/8664723","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

二甲双胍是一种口服双胍类降血糖药,用于降低 2 型糖尿病患者的血糖水平。许多分析技术已被用于定量分析不同药物剂型中的二甲双胍,但大多数方法在质量控制应用中的通量有限。最近有报道称,一种一次性电位微传感器对二甲双胍有反应。本文首次根据国际理论化学和应用化学联合会(IUPAC)的建议对该分析方法进行了验证,并将其成功应用于某些剂型中二甲双胍药物的测定。我们从沙特阿拉伯当地的药店收集了盐酸二甲双胍的不同药物制剂,并使用经过验证的微芯片分析方法进行了分析。研究结果表明,该方法线性、特异、精密、准确。线性范围为 1 × 10-1-1 × 10-5 mol L-1,相关系数为 0.999。检出限为 2.89 × 10-6 mol L-1,定量限为 8.77 × 10-6 mol L-1。该方法的精密度高,RSD%小于 2.22%。该方法的准确度是通过比较回收率与小于 5%的百分比值得出的。结果表明,参照物、标签和小于 5%的回收率之间没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation and Application of Screen-Printed Microchip for Potentiometric Determination of Metformin Hydrochloride in Tablet Dosage Form
Metformin is an oral biguanides hypoglycaemic agent, which used to lower the blood glucose levels in people with type 2 diabetes mellitus. Many analytical techniques have been used to quantify the drug in different pharmaceutical dosage forms; however, most of these methods have limited throughput in the quality control application. A disposable potentiometric microsensor responsive to metformin has recently been reported. For the first time, herein, this method of analysis has been validated according to IUPAC recommendations and successfully applied in the determination of metformin drug in some dosage form. Different drug formulations of metformin hydrochloride have been collected from the local pharmaceutical stores in Saudi Arabia and analysed using the validated microchip-based method of analysis. Subsequently, the results of this study showed that the validated method was linear, specific, precise, and accurate. The linear range was 1 × 10−1–1 × 10−5 mol L−1 and the correlation coefficient was 0.999. The limit of detection was 2.89 × 10−6 mol L−1, and the limit of quantification was 8.77 × 10−6 mol L−1. This method demonstrated high precision, with an RSD% of less than 2.22%. The accuracy of this method was obtained by comparing the recovery percentage with percentage values less than 5%. The results obtained showed that there was no significant difference between the references, label, and recovery of less than 5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
5.60%
发文量
117
期刊介绍: International Journal of Analytical Chemistry publishes original research articles that report new experimental results and methods, especially in relation to important analytes, difficult matrices, and topical samples. Investigations may be fundamental, or else related to specific applications; examples being biological, environmental and food testing, and analysis in chemical synthesis and materials processing. As well as original research, the International Journal of Analytical Chemistry also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.
期刊最新文献
Formation and Physicochemical Properties of Freeze-Dried Amyloid-Like Fibrils From Pinto Bean Protein: Amyloid-Like Fibrils From Pinto Bean Protein. Prediction of Lycii Cortex Quality Marker Based on Network Pharmacology and Chemometrics Methods. Determination of Alzheimer's Drugs in a Human Urine Sample by Different Chemometric Methods: Chemometric Determination of Alzheimer's Drugs. Development of the Pipette-Tip Micro-Solid-Phase Extraction for Extraction of Rutin From Moringa oleifera Lam. Using Activated Hollow Carbon Nanospheres as Sorbents. Establishment of a Generalizable Industrial Crop Model for Microwave Extraction of Unsaturated Fatty Acids.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1