虹吸管形态对 C7 节段动脉瘤形成风险的影响:病例对照 CFD 研究。

IF 2.8 3区 医学 Q2 Medicine Clinical Neuroradiology Pub Date : 2024-06-01 Epub Date: 2024-02-28 DOI:10.1007/s00062-024-01394-3
Ying Wang, Bo Chen, Laixin Song, Yuzhe Li, Ming Xu, Tianxiang Huang, Feiyue Zeng
{"title":"虹吸管形态对 C7 节段动脉瘤形成风险的影响:病例对照 CFD 研究。","authors":"Ying Wang, Bo Chen, Laixin Song, Yuzhe Li, Ming Xu, Tianxiang Huang, Feiyue Zeng","doi":"10.1007/s00062-024-01394-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Tortuosity of the internal carotid artery (ICA) is associated with intracranial aneurysms (IAs). The siphon is the most curved segment of the ICA, but its morphology has controversial effects on IAs. This study aimed to explore the morphometric features of the siphon and the potential hemodynamic mechanisms that may affect C7 aneurysm formation.</p><p><strong>Methods: </strong>In this study 32 patients with C7 aneurysms diagnosed at Xiangya Hospital between 2019 and 2021 and 32 control subjects were enrolled after propensity score matching. Computed tomography angiography (CTA) images were acquired to measure morphologic features, and then, by combining clinical data, simplified carotid siphon models were constructed, and computational fluid dynamics (CFD) analysis was performed.</p><p><strong>Results: </strong>The presence of C7 aneurysms was associated with the height of the C4-C6 curved arteries (odds ratio [OR] 0.028, 95% confidence interval [CI] 0.003-0.201; P < 0.001). The heights of the C4-C6 curved arteries in the aneurysm group were significantly shorter than those in the control group. The CFD analysis revealed that shorter C4-C6 bends led to greater blood velocity and pressure in the C7 segment arteries.</p><p><strong>Conclusion: </strong>A shorter C4-C6 bend was associated with distal C7 aneurysm formation, and an elaborate hemodynamic mechanism may underlie this association.</p>","PeriodicalId":10391,"journal":{"name":"Clinical Neuroradiology","volume":" ","pages":"485-494"},"PeriodicalIF":2.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130050/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of Siphon Morphology on the Risk of C7 Segment Aneurysm Formation : A Case-control CFD Study.\",\"authors\":\"Ying Wang, Bo Chen, Laixin Song, Yuzhe Li, Ming Xu, Tianxiang Huang, Feiyue Zeng\",\"doi\":\"10.1007/s00062-024-01394-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Tortuosity of the internal carotid artery (ICA) is associated with intracranial aneurysms (IAs). The siphon is the most curved segment of the ICA, but its morphology has controversial effects on IAs. This study aimed to explore the morphometric features of the siphon and the potential hemodynamic mechanisms that may affect C7 aneurysm formation.</p><p><strong>Methods: </strong>In this study 32 patients with C7 aneurysms diagnosed at Xiangya Hospital between 2019 and 2021 and 32 control subjects were enrolled after propensity score matching. Computed tomography angiography (CTA) images were acquired to measure morphologic features, and then, by combining clinical data, simplified carotid siphon models were constructed, and computational fluid dynamics (CFD) analysis was performed.</p><p><strong>Results: </strong>The presence of C7 aneurysms was associated with the height of the C4-C6 curved arteries (odds ratio [OR] 0.028, 95% confidence interval [CI] 0.003-0.201; P < 0.001). The heights of the C4-C6 curved arteries in the aneurysm group were significantly shorter than those in the control group. The CFD analysis revealed that shorter C4-C6 bends led to greater blood velocity and pressure in the C7 segment arteries.</p><p><strong>Conclusion: </strong>A shorter C4-C6 bend was associated with distal C7 aneurysm formation, and an elaborate hemodynamic mechanism may underlie this association.</p>\",\"PeriodicalId\":10391,\"journal\":{\"name\":\"Clinical Neuroradiology\",\"volume\":\" \",\"pages\":\"485-494\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130050/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00062-024-01394-3\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00062-024-01394-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:颈内动脉(ICA)的迂曲与颅内动脉瘤(IAs)有关。虹吸管是颈内动脉最弯曲的部分,但其形态对颅内动脉瘤的影响存在争议。本研究旨在探讨虹吸管的形态特征以及可能影响 C7 动脉瘤形成的潜在血液动力学机制:本研究中,湘雅医院在2019年至2021年期间确诊的32例C7动脉瘤患者和32例对照受试者经倾向评分匹配后入选。采集计算机断层扫描血管造影(CTA)图像测量形态学特征,然后结合临床数据,构建简化颈动脉虹吸管模型,并进行计算流体动力学(CFD)分析:结果:C7动脉瘤的存在与C4-C6弯曲动脉的高度有关(几率比[OR]0.028,95%置信区间[CI]0.003-0.201;P 结论:C7动脉瘤的存在与C4-C6弯曲动脉的高度有关:较短的C4-C6弯曲动脉与C7远端动脉瘤的形成有关,这种关联可能是一种复杂的血液动力学机制造成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Siphon Morphology on the Risk of C7 Segment Aneurysm Formation : A Case-control CFD Study.

Purpose: Tortuosity of the internal carotid artery (ICA) is associated with intracranial aneurysms (IAs). The siphon is the most curved segment of the ICA, but its morphology has controversial effects on IAs. This study aimed to explore the morphometric features of the siphon and the potential hemodynamic mechanisms that may affect C7 aneurysm formation.

Methods: In this study 32 patients with C7 aneurysms diagnosed at Xiangya Hospital between 2019 and 2021 and 32 control subjects were enrolled after propensity score matching. Computed tomography angiography (CTA) images were acquired to measure morphologic features, and then, by combining clinical data, simplified carotid siphon models were constructed, and computational fluid dynamics (CFD) analysis was performed.

Results: The presence of C7 aneurysms was associated with the height of the C4-C6 curved arteries (odds ratio [OR] 0.028, 95% confidence interval [CI] 0.003-0.201; P < 0.001). The heights of the C4-C6 curved arteries in the aneurysm group were significantly shorter than those in the control group. The CFD analysis revealed that shorter C4-C6 bends led to greater blood velocity and pressure in the C7 segment arteries.

Conclusion: A shorter C4-C6 bend was associated with distal C7 aneurysm formation, and an elaborate hemodynamic mechanism may underlie this association.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Neuroradiology
Clinical Neuroradiology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.90
自引率
3.60%
发文量
0
期刊介绍: Clinical Neuroradiology provides current information, original contributions, and reviews in the field of neuroradiology. An interdisciplinary approach is accomplished by diagnostic and therapeutic contributions related to associated subjects. The international coverage and relevance of the journal is underlined by its being the official journal of the German, Swiss, and Austrian Societies of Neuroradiology.
期刊最新文献
Societies' Communications. Long-term Safety and Efficacy of the Derivo Embolization Device in a Single-center Series. Clinical Use of Hematoma Volume Based On Automated Segmentation of Chronic Subdural Hematoma Using 3D U-Net. Radiomics Analysis of Quantitative Maps from Synthetic MRI for Predicting Grades and Molecular Subtypes of Diffuse Gliomas. Propensity Score-matched Comparison of WEB 17 and WEB 21 with 4-7 mm Device Sizes for the Treatment of Unruptured Intracranial Aneurysms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1