原发性先天性青光眼患者视野缺损的八爪鱼周边测量法检测和定性。

L. Morales-Fernández , J.M. Martínez-de-la-Casa , F. Sáenz-Francés , P. Pérez-García , L. Borrego-Sanz , J. García-Feijóo
{"title":"原发性先天性青光眼患者视野缺损的八爪鱼周边测量法检测和定性。","authors":"L. Morales-Fernández ,&nbsp;J.M. Martínez-de-la-Casa ,&nbsp;F. Sáenz-Francés ,&nbsp;P. Pérez-García ,&nbsp;L. Borrego-Sanz ,&nbsp;J. García-Feijóo","doi":"10.1016/j.oftal.2023.10.014","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration.</p></div><div><h3>Material and methods</h3><p>Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed.</p></div><div><h3>Results</h3><p>Median age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD<!--> <!-->=<!--> <!-->23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n<!--> <!-->=<!--> <!-->15), nasal step (n<!--> <!-->=<!--> <!-->8), adding arcuate defect (n<!--> <!-->=<!--> <!-->2), half ring-shaped (n<!--> <!-->=<!--> <!-->13) and concentric defect with a central island (n<!--> <!-->=<!--> <!-->9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2<!--> <!-->min 12<!--> <!-->s (SD: 21.6<!--> <!-->s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all <em>P</em> <!-->&lt;<!--> <!-->.001).</p></div><div><h3>Conclusion</h3><p>A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.</p></div>","PeriodicalId":8348,"journal":{"name":"Archivos De La Sociedad Espanola De Oftalmologia","volume":"99 3","pages":"Pages 91-97"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detección y caracterización de defectos del campo visual mediante perimetría Octopus en glaucoma congénito primario\",\"authors\":\"L. Morales-Fernández ,&nbsp;J.M. Martínez-de-la-Casa ,&nbsp;F. Sáenz-Francés ,&nbsp;P. Pérez-García ,&nbsp;L. Borrego-Sanz ,&nbsp;J. García-Feijóo\",\"doi\":\"10.1016/j.oftal.2023.10.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration.</p></div><div><h3>Material and methods</h3><p>Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed.</p></div><div><h3>Results</h3><p>Median age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD<!--> <!-->=<!--> <!-->23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n<!--> <!-->=<!--> <!-->15), nasal step (n<!--> <!-->=<!--> <!-->8), adding arcuate defect (n<!--> <!-->=<!--> <!-->2), half ring-shaped (n<!--> <!-->=<!--> <!-->13) and concentric defect with a central island (n<!--> <!-->=<!--> <!-->9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2<!--> <!-->min 12<!--> <!-->s (SD: 21.6<!--> <!-->s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all <em>P</em> <!-->&lt;<!--> <!-->.001).</p></div><div><h3>Conclusion</h3><p>A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.</p></div>\",\"PeriodicalId\":8348,\"journal\":{\"name\":\"Archivos De La Sociedad Espanola De Oftalmologia\",\"volume\":\"99 3\",\"pages\":\"Pages 91-97\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivos De La Sociedad Espanola De Oftalmologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0365669123002083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos De La Sociedad Espanola De Oftalmologia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0365669123002083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的 使用静态八达通验光仪检测原发性先天性青光眼(PCG)患者的视野(VF)缺陷并确定其特征,同时确定 VF 的质量和持续时间。使用 Octopus 900 进行评估,每只眼均使用趋势导向型验光仪 (G-TOP) 算法进行评估。收集的 VF 定量数据包括:质量数据(假阳性和假阴性反应以及持续时间)、平均偏差(MD)和损失方差平方根(sLV)的结果。收集的定性数据包括:是否存在弥漫性和局部性缺损、受影响的半视野以及采用 Aulhorn 和 Karmeyer 分类法得出的缺损等级。结果平均年龄为 11(8-17)岁。65.9%(58/88)的 PCG 眼睛出现 VF 缺陷。在 10/58 只眼睛(16.94%)中观察到弥漫性缺陷(平均 MD = 23.92 [SD: 2.52]) dB),在 48/58 只眼睛(82.75%)中观察到局部缺陷。最常见的缺损是点状/卒中样/原发性旁中心视网膜障(15 例)、鼻阶(8 例)、弧形缺损(2 例)、半环形(13 例)和带中心岛的同心圆缺损(9 例)。最常受影响的视半球是下半球。平均测试时间为 2 分 12 秒(标准差:21.6 秒)。MD 和 sLV 值与最佳矫正视力 (BCVA)、杯盘比和抗青光眼手术次数相关(均为 P < .001)。最常见的缺陷是旁中心视网膜障,下半视野受影响最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detección y caracterización de defectos del campo visual mediante perimetría Octopus en glaucoma congénito primario

Purpose

To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration.

Material and methods

Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed.

Results

Median age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD = 23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n = 15), nasal step (n = 8), adding arcuate defect (n = 2), half ring-shaped (n = 13) and concentric defect with a central island (n = 9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2 min 12 s (SD: 21.6 s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P < .001).

Conclusion

A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
109
审稿时长
78 days
期刊介绍: La revista Archivos de la Sociedad Española de Oftalmología, editada mensualmente por la propia Sociedad, tiene como objetivo publicar trabajos de investigación básica y clínica como artículos originales; casos clínicos, innovaciones técnicas y correlaciones clinicopatológicas en forma de comunicaciones cortas; editoriales; revisiones; cartas al editor; comentarios de libros; información de eventos; noticias personales y anuncios comerciales, así como trabajos de temas históricos y motivos inconográficos relacionados con la Oftalmología. El título abreviado es Arch Soc Esp Oftalmol, y debe ser utilizado en bibliografías, notas a pie de página y referencias bibliográficas.
期刊最新文献
Tomografía de coherencia óptica de segmento anterior para el diagnóstico diferencial de quiste de iris Prevalencia y factores de riesgo para padecer una uveítis inmunomediada con mal pronóstico ocular: experiencia en un hospital de tercer nivel Hallazgos en la tomografía de coherencia óptica de segmento anterior (OCT-SA) en la cirugía de glaucoma tras el implante del Preserflo® Microshunt Propuesta de incidentes graves en productos sanitarios utilizados en la cirugía del segmento anterior. Proponiendo ideas (II) Neovascularización coroidea en niños: etiología, características clínicas y resultados del tratamiento
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1