Florian van Dellen, Tabea Aurich-Schuler, Carla Burkhardt, Rob Labruyère
{"title":"具体指令很重要:一项关于儿童和青少年使用机器人行走时的设备参数和指令类型的横断面研究。","authors":"Florian van Dellen, Tabea Aurich-Schuler, Carla Burkhardt, Rob Labruyère","doi":"10.1097/PHM.0000000000002472","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the study is to evaluate how gait kinematics and muscle activity during robot-assisted gait training are affected by different combinations of parameter settings and a number of instruction types, ranging from no instructions to goal-specific instructions.</p><p><strong>Design: </strong>Robots for gait therapy provide a haptic guidance, but too much guidance can limit the active participation. Therapists can stimulate this active participation either with instructions or by adapting device parameters. How these two factors interact is still unknown. In the present study, we test the interaction of three different parameter settings and four instruction types in a cross-sectional study with 20 children and adolescents without impairment. Gait kinematics and surface electromyography were measured to evaluate the immediate effects.</p><p><strong>Results: </strong>We found that only goal-specific instructions in combination with a low guidance led to a moderate but significant change in gait kinematics. The muscle activity was altered by all instructions, but the biggest effect was found for goal-specific instructions with a 2.5 times higher surface electromyography amplitude compared to no instruction.</p><p><strong>Conclusions: </strong>Goal-specific instructions are a key element of robot-assisted gait therapy interventions and device parameter adjustments may be used to modulate their effects. Therapists should pay close attention to how they instruct patients.</p>","PeriodicalId":7850,"journal":{"name":"American Journal of Physical Medicine & Rehabilitation","volume":" ","pages":"904-910"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Specific Instructions Are Important: A Cross-sectional Study on Device Parameters and Instruction Types While Walking With a Robot in Children and Adolescents.\",\"authors\":\"Florian van Dellen, Tabea Aurich-Schuler, Carla Burkhardt, Rob Labruyère\",\"doi\":\"10.1097/PHM.0000000000002472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of the study is to evaluate how gait kinematics and muscle activity during robot-assisted gait training are affected by different combinations of parameter settings and a number of instruction types, ranging from no instructions to goal-specific instructions.</p><p><strong>Design: </strong>Robots for gait therapy provide a haptic guidance, but too much guidance can limit the active participation. Therapists can stimulate this active participation either with instructions or by adapting device parameters. How these two factors interact is still unknown. In the present study, we test the interaction of three different parameter settings and four instruction types in a cross-sectional study with 20 children and adolescents without impairment. Gait kinematics and surface electromyography were measured to evaluate the immediate effects.</p><p><strong>Results: </strong>We found that only goal-specific instructions in combination with a low guidance led to a moderate but significant change in gait kinematics. The muscle activity was altered by all instructions, but the biggest effect was found for goal-specific instructions with a 2.5 times higher surface electromyography amplitude compared to no instruction.</p><p><strong>Conclusions: </strong>Goal-specific instructions are a key element of robot-assisted gait therapy interventions and device parameter adjustments may be used to modulate their effects. Therapists should pay close attention to how they instruct patients.</p>\",\"PeriodicalId\":7850,\"journal\":{\"name\":\"American Journal of Physical Medicine & Rehabilitation\",\"volume\":\" \",\"pages\":\"904-910\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Physical Medicine & Rehabilitation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PHM.0000000000002472\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Physical Medicine & Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PHM.0000000000002472","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
Specific Instructions Are Important: A Cross-sectional Study on Device Parameters and Instruction Types While Walking With a Robot in Children and Adolescents.
Objective: The aim of the study is to evaluate how gait kinematics and muscle activity during robot-assisted gait training are affected by different combinations of parameter settings and a number of instruction types, ranging from no instructions to goal-specific instructions.
Design: Robots for gait therapy provide a haptic guidance, but too much guidance can limit the active participation. Therapists can stimulate this active participation either with instructions or by adapting device parameters. How these two factors interact is still unknown. In the present study, we test the interaction of three different parameter settings and four instruction types in a cross-sectional study with 20 children and adolescents without impairment. Gait kinematics and surface electromyography were measured to evaluate the immediate effects.
Results: We found that only goal-specific instructions in combination with a low guidance led to a moderate but significant change in gait kinematics. The muscle activity was altered by all instructions, but the biggest effect was found for goal-specific instructions with a 2.5 times higher surface electromyography amplitude compared to no instruction.
Conclusions: Goal-specific instructions are a key element of robot-assisted gait therapy interventions and device parameter adjustments may be used to modulate their effects. Therapists should pay close attention to how they instruct patients.
期刊介绍:
American Journal of Physical Medicine & Rehabilitation focuses on the practice, research and educational aspects of physical medicine and rehabilitation. Monthly issues keep physiatrists up-to-date on the optimal functional restoration of patients with disabilities, physical treatment of neuromuscular impairments, the development of new rehabilitative technologies, and the use of electrodiagnostic studies. The Journal publishes cutting-edge basic and clinical research, clinical case reports and in-depth topical reviews of interest to rehabilitation professionals.
Topics include prevention, diagnosis, treatment, and rehabilitation of musculoskeletal conditions, brain injury, spinal cord injury, cardiopulmonary disease, trauma, acute and chronic pain, amputation, prosthetics and orthotics, mobility, gait, and pediatrics as well as areas related to education and administration. Other important areas of interest include cancer rehabilitation, aging, and exercise. The Journal has recently published a series of articles on the topic of outcomes research. This well-established journal is the official scholarly publication of the Association of Academic Physiatrists (AAP).