基于商用现成 CMOS 图像传感器的小动物样本高分辨率 X 射线成像。

IF 1.7 3区 医学 Q3 INSTRUMENTS & INSTRUMENTATION Journal of X-Ray Science and Technology Pub Date : 2024-01-01 DOI:10.3233/XST-230232
MartÍn Pérez, Gerardo M Lado, Germán Mato, Diego G Franco, Ignacio Artola Vinciguerra, Mariano Gómez Berisso, Federico J Pomiro, José Lipovetzky, Luciano Marpegan
{"title":"基于商用现成 CMOS 图像传感器的小动物样本高分辨率 X 射线成像。","authors":"MartÍn Pérez, Gerardo M Lado, Germán Mato, Diego G Franco, Ignacio Artola Vinciguerra, Mariano Gómez Berisso, Federico J Pomiro, José Lipovetzky, Luciano Marpegan","doi":"10.3233/XST-230232","DOIUrl":null,"url":null,"abstract":"<p><p> An automated system for acquiring microscopic-resolution radiographic images of biological samples was developed. Mass-produced, low-cost, and easily automated components were used, such as Commercial-Off-The-Self CMOS image sensors (CIS), stepper motors, and control boards based on Arduino and RaspberryPi. System configuration, imaging protocols, and Image processing (filtering and stitching) were defined to obtain high-resolution images and for successful computational image reconstruction. Radiographic images were obtained for animal samples including the widely used animal models zebrafish (Danio rerio) and the fruit-fly (Drosophila melanogaster), as well as other small animal samples. The use of phosphotungstic acid (PTA) as a contrast agent was also studied. Radiographic images with resolutions of up to (7±0.6)μm were obtained, making this system comparable to commercial ones. This work constitutes a starting point for the development of more complex systems such as X-ray attenuation micro-tomography systems based on low-cost off-the-shelf technology. It will also bring the possibility to expand the studies that can be carried out with small animal models at many institutions (mostly those working on tight budgets), particularly those on the effects of ionizing radiation and absorption of heavy metal contaminants in animal tissues.</p>","PeriodicalId":49948,"journal":{"name":"Journal of X-Ray Science and Technology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-resolution X-Ray imaging of small animal samples based on Commercial-Off-The-Shelf CMOS image sensors.\",\"authors\":\"MartÍn Pérez, Gerardo M Lado, Germán Mato, Diego G Franco, Ignacio Artola Vinciguerra, Mariano Gómez Berisso, Federico J Pomiro, José Lipovetzky, Luciano Marpegan\",\"doi\":\"10.3233/XST-230232\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p> An automated system for acquiring microscopic-resolution radiographic images of biological samples was developed. Mass-produced, low-cost, and easily automated components were used, such as Commercial-Off-The-Self CMOS image sensors (CIS), stepper motors, and control boards based on Arduino and RaspberryPi. System configuration, imaging protocols, and Image processing (filtering and stitching) were defined to obtain high-resolution images and for successful computational image reconstruction. Radiographic images were obtained for animal samples including the widely used animal models zebrafish (Danio rerio) and the fruit-fly (Drosophila melanogaster), as well as other small animal samples. The use of phosphotungstic acid (PTA) as a contrast agent was also studied. Radiographic images with resolutions of up to (7±0.6)μm were obtained, making this system comparable to commercial ones. This work constitutes a starting point for the development of more complex systems such as X-ray attenuation micro-tomography systems based on low-cost off-the-shelf technology. It will also bring the possibility to expand the studies that can be carried out with small animal models at many institutions (mostly those working on tight budgets), particularly those on the effects of ionizing radiation and absorption of heavy metal contaminants in animal tissues.</p>\",\"PeriodicalId\":49948,\"journal\":{\"name\":\"Journal of X-Ray Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of X-Ray Science and Technology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/XST-230232\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of X-Ray Science and Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/XST-230232","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

我们开发了一种自动系统,用于获取生物样本的显微分辨率射线图像。该系统使用了批量生产、低成本和易于自动化的组件,如商用自产 CMOS 图像传感器 (CIS)、步进电机和基于 Arduino 和 RaspberryPi 的控制板。系统配置、成像协议和图像处理(滤波和拼接)的定义是为了获得高分辨率图像和成功的计算图像重建。获得了动物样本的放射图像,包括广泛使用的动物模型斑马鱼(Danio rerio)和果蝇(Drosophila melanogaster),以及其他小动物样本。此外,还研究了磷钨酸(PTA)作为造影剂的用途。该系统获得了分辨率高达 (7±0.6) μm 的射线图像,可与商用系统媲美。这项工作为开发更复杂的系统(如基于低成本现成技术的 X 射线衰减微层析成像系统)提供了一个起点。它还将为许多机构(主要是那些预算紧张的机构)扩大利用小型动物模型开展的研究提供可能,特别是那些关于电离辐射影响和动物组织吸收重金属污染物的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-resolution X-Ray imaging of small animal samples based on Commercial-Off-The-Shelf CMOS image sensors.

 An automated system for acquiring microscopic-resolution radiographic images of biological samples was developed. Mass-produced, low-cost, and easily automated components were used, such as Commercial-Off-The-Self CMOS image sensors (CIS), stepper motors, and control boards based on Arduino and RaspberryPi. System configuration, imaging protocols, and Image processing (filtering and stitching) were defined to obtain high-resolution images and for successful computational image reconstruction. Radiographic images were obtained for animal samples including the widely used animal models zebrafish (Danio rerio) and the fruit-fly (Drosophila melanogaster), as well as other small animal samples. The use of phosphotungstic acid (PTA) as a contrast agent was also studied. Radiographic images with resolutions of up to (7±0.6)μm were obtained, making this system comparable to commercial ones. This work constitutes a starting point for the development of more complex systems such as X-ray attenuation micro-tomography systems based on low-cost off-the-shelf technology. It will also bring the possibility to expand the studies that can be carried out with small animal models at many institutions (mostly those working on tight budgets), particularly those on the effects of ionizing radiation and absorption of heavy metal contaminants in animal tissues.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.90
自引率
23.30%
发文量
150
审稿时长
3 months
期刊介绍: Research areas within the scope of the journal include: Interaction of x-rays with matter: x-ray phenomena, biological effects of radiation, radiation safety and optical constants X-ray sources: x-rays from synchrotrons, x-ray lasers, plasmas, and other sources, conventional or unconventional Optical elements: grazing incidence optics, multilayer mirrors, zone plates, gratings, other diffraction optics Optical instruments: interferometers, spectrometers, microscopes, telescopes, microprobes
期刊最新文献
Adaptive prior image constrained total generalized variation for low-dose dynamic cerebral perfusion CT reconstruction. A comprehensive guide to content-based image retrieval algorithms with visualsift ensembling. Multiscale unsupervised network for deformable image registration. Extracellular volume fraction of liver and pancreas using spectral CT in hypertensive patients: A comparative study. Dosimetric effect of collimator rotation on intensity modulated radiotherapy and volumetric modulated arc therapy for rectal cancer radiotherapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1