{"title":"利用分裂树在微电极点阵数字微流控生物芯片上制备样品时尽量减少反应物和废物","authors":"","doi":"10.1007/s10836-024-06103-z","DOIUrl":null,"url":null,"abstract":"<h3>Abstract</h3> <p>Biological assays around “lab-on-a-chip (LoC)” are required in multiple concentration (or dilution) factors, satisfying specific sample concentrations. Unfortunately, most of them suffer from non-locality and are non-protectable, requiring a large footprint and high purchase cost. A digital geometric technique can generate arbitrary gradient profiles for digital microfluidic biochips (DMFBs). A next- generation DMFB has been proposed based on the microelectrode-dot-array (MEDA) architectures are shown to produce and disperse droplets by channel dispensing and lamination mixing. Prior work in this area must address the problem of reactant and waste minimization and concurrent sample preparation for multiple target concentrations. This paper proposes the first splitting-droplet sharing algorithm for reactant and waste minimization of multiple target concentrations on MEDAs. The proposed algorithm not only minimizes the consumption of reagents but also reduces the number of waste droplets by preparing the target concentrations concurrently. Experimental results on a sequence of exponential gradients are presented in support of the proposed method and demonstrate its effectiveness and efficiency. Compared to prior work, the proposed algorithm can achieve up to a 24.8% reduction in sample usage and reach an average of 50% reduction in waste droplets.</p>","PeriodicalId":501485,"journal":{"name":"Journal of Electronic Testing","volume":"73 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reactant and Waste Minimization during Sample Preparation on Micro-Electrode-Dot-Array Digital Microfluidic Biochips using Splitting Trees\",\"authors\":\"\",\"doi\":\"10.1007/s10836-024-06103-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3>Abstract</h3> <p>Biological assays around “lab-on-a-chip (LoC)” are required in multiple concentration (or dilution) factors, satisfying specific sample concentrations. Unfortunately, most of them suffer from non-locality and are non-protectable, requiring a large footprint and high purchase cost. A digital geometric technique can generate arbitrary gradient profiles for digital microfluidic biochips (DMFBs). A next- generation DMFB has been proposed based on the microelectrode-dot-array (MEDA) architectures are shown to produce and disperse droplets by channel dispensing and lamination mixing. Prior work in this area must address the problem of reactant and waste minimization and concurrent sample preparation for multiple target concentrations. This paper proposes the first splitting-droplet sharing algorithm for reactant and waste minimization of multiple target concentrations on MEDAs. The proposed algorithm not only minimizes the consumption of reagents but also reduces the number of waste droplets by preparing the target concentrations concurrently. Experimental results on a sequence of exponential gradients are presented in support of the proposed method and demonstrate its effectiveness and efficiency. Compared to prior work, the proposed algorithm can achieve up to a 24.8% reduction in sample usage and reach an average of 50% reduction in waste droplets.</p>\",\"PeriodicalId\":501485,\"journal\":{\"name\":\"Journal of Electronic Testing\",\"volume\":\"73 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electronic Testing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10836-024-06103-z\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronic Testing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10836-024-06103-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要 围绕 "片上实验室(LoC)"的生物检测需要多种浓度(或稀释)因子,以满足特定样品浓度的要求。遗憾的是,它们大多具有非定位性和不可保护性,需要占用大量空间,购买成本高昂。数字几何技术可为数字微流控生物芯片(DMFB)生成任意梯度曲线。基于微电极点阵(MEDA)结构的下一代 DMFB 已被提出,该结构可通过通道分配和层叠混合来产生和分散液滴。该领域的前期工作必须解决反应物和废物最小化以及同时制备多目标浓度样品的问题。本文首次提出了在 MEDA 上实现多目标浓度反应物和废物最小化的分裂-液滴共享算法。所提出的算法不仅最大限度地减少了试剂消耗,还通过同时制备目标浓度样品减少了废液滴的数量。为了支持所提出的方法,我们展示了一系列指数梯度的实验结果,证明了该方法的有效性和高效性。与之前的工作相比,所提出的算法最多可减少 24.8% 的样品用量,平均减少 50% 的废液滴。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reactant and Waste Minimization during Sample Preparation on Micro-Electrode-Dot-Array Digital Microfluidic Biochips using Splitting Trees

Abstract

Biological assays around “lab-on-a-chip (LoC)” are required in multiple concentration (or dilution) factors, satisfying specific sample concentrations. Unfortunately, most of them suffer from non-locality and are non-protectable, requiring a large footprint and high purchase cost. A digital geometric technique can generate arbitrary gradient profiles for digital microfluidic biochips (DMFBs). A next- generation DMFB has been proposed based on the microelectrode-dot-array (MEDA) architectures are shown to produce and disperse droplets by channel dispensing and lamination mixing. Prior work in this area must address the problem of reactant and waste minimization and concurrent sample preparation for multiple target concentrations. This paper proposes the first splitting-droplet sharing algorithm for reactant and waste minimization of multiple target concentrations on MEDAs. The proposed algorithm not only minimizes the consumption of reagents but also reduces the number of waste droplets by preparing the target concentrations concurrently. Experimental results on a sequence of exponential gradients are presented in support of the proposed method and demonstrate its effectiveness and efficiency. Compared to prior work, the proposed algorithm can achieve up to a 24.8% reduction in sample usage and reach an average of 50% reduction in waste droplets.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Automatic Software Testing Method to Discover Hard-to-Detect Faults Using Hybrid Olympiad Optimization Algorithm High-Dimensional Feature Fault Diagnosis Method Based on HEFS-LGBM Pebble Traversal-Based Fault Detection and Advanced Reconfiguration Technique for Digital Microfluidic Biochips Predicting Energy Dissipation in QCA-Based Layered-T Gates Under Cell Defects and Polarisation: A Study with Machine-Learning Models Investigation of Silicon Aging Effects in Dopingless PUF for Reliable Security Solution
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1