Zainal Arifin, Fachruroji Fachruroji, Muhammad Huda
{"title":"通过负荷优化提高高层建筑冷水机系统的性能","authors":"Zainal Arifin, Fachruroji Fachruroji, Muhammad Huda","doi":"10.11591/ijape.v13.i1.pp113-122","DOIUrl":null,"url":null,"abstract":"Recently, the construction of high-rise buildings has been increasing significantly along with economic growth. Therefore, electricity is also going up due to the energy demand of the building. The air conditioning system is the enormous energy consumption in high buildings. The green building concept has been introduced regarding the energy efficiency of a high-rise building. This study investigated the energy consumption in a high building (47 floors) using the load optimization method for the chiller system. The load optimization was conducted by configuring five chillers systems consisting of integral compressors, cooling towers, and pumps. This study obtained the decreasing energy consumption by the chiller's operation load sequencing based on 24-hour data optimization. Optimized chiller performance satisfied the green building standards. However, load optimization on high buildings is highly recommended as an effective way to achieve green building status. Further research is recommended for implementing such optimization at other facilities, such as industrial plants, hospitals, airports, and manufacturing plants.","PeriodicalId":340072,"journal":{"name":"International Journal of Applied Power Engineering (IJAPE)","volume":"123 42","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Increasing performance of chiller systems in high-rise buildings by load optimization\",\"authors\":\"Zainal Arifin, Fachruroji Fachruroji, Muhammad Huda\",\"doi\":\"10.11591/ijape.v13.i1.pp113-122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, the construction of high-rise buildings has been increasing significantly along with economic growth. Therefore, electricity is also going up due to the energy demand of the building. The air conditioning system is the enormous energy consumption in high buildings. The green building concept has been introduced regarding the energy efficiency of a high-rise building. This study investigated the energy consumption in a high building (47 floors) using the load optimization method for the chiller system. The load optimization was conducted by configuring five chillers systems consisting of integral compressors, cooling towers, and pumps. This study obtained the decreasing energy consumption by the chiller's operation load sequencing based on 24-hour data optimization. Optimized chiller performance satisfied the green building standards. However, load optimization on high buildings is highly recommended as an effective way to achieve green building status. Further research is recommended for implementing such optimization at other facilities, such as industrial plants, hospitals, airports, and manufacturing plants.\",\"PeriodicalId\":340072,\"journal\":{\"name\":\"International Journal of Applied Power Engineering (IJAPE)\",\"volume\":\"123 42\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering (IJAPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/ijape.v13.i1.pp113-122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering (IJAPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijape.v13.i1.pp113-122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Increasing performance of chiller systems in high-rise buildings by load optimization
Recently, the construction of high-rise buildings has been increasing significantly along with economic growth. Therefore, electricity is also going up due to the energy demand of the building. The air conditioning system is the enormous energy consumption in high buildings. The green building concept has been introduced regarding the energy efficiency of a high-rise building. This study investigated the energy consumption in a high building (47 floors) using the load optimization method for the chiller system. The load optimization was conducted by configuring five chillers systems consisting of integral compressors, cooling towers, and pumps. This study obtained the decreasing energy consumption by the chiller's operation load sequencing based on 24-hour data optimization. Optimized chiller performance satisfied the green building standards. However, load optimization on high buildings is highly recommended as an effective way to achieve green building status. Further research is recommended for implementing such optimization at other facilities, such as industrial plants, hospitals, airports, and manufacturing plants.