{"title":"用于心肌病一级预防的植入式心律转复除颤器。","authors":"Vineetha Kanneganti , Ajay Bahl , Manoj Kumar Rohit , Saurabh Mehrotra","doi":"10.1016/j.ihj.2024.03.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Implantable cardioverter defibrillators (ICD) are often used as primary prevention strategy for sudden cardiac death (SCD) in young individuals. This study analyzed appropriate therapies, complications and inappropriate shocks in the real-world Indian population.</p></div><div><h3>Methods</h3><p>All patients in the cardiomyopathy cohort under follow up who had ICD implanted as a primary prevention strategy were studied. The objective was to assess the incidence of appropriate ICD therapies, inappropriate therapies and complications. ICD was interrogated and stored electrograms analyzed. Underlying arrhythmia or conditions resulting in appropriate or inappropriate ICD therapy were studied. Correlation and regression studies was done to assess for the predictors of appropriate therapy.</p></div><div><h3>Results</h3><p>Fifty patients were followed up for a mean follow-up duration of 4.4 ± 3.1 years with total follow up of 220.2 patient years. Appropriate ICD therapy was delivered in 16 out of 50 (32%) patients, with 65 appropriate therapies (median 2 per patient, range: 0–20). Inappropriate therapy delivered in 7 of the 50 (14%) patients, with 44 inappropriate therapies (median 5 per patient, range: 0–20). Complications occurred in 8 of the 50 (16%) patients. Overall, the rate of appropriate therapy was 29.5 per 100 patient years, that of inappropriate therapy was 19.9 per 100 patient years and the rate of complications was 3.6 per 100 patient years.</p></div><div><h3>Conclusions</h3><p>When implanted for primary prevention in patients with cardiomyopathies over a mean period of 4.4 ± 3.1 years, appropriate ICD therapy was delivered in 32% patients. However, inappropriate therapy (14% patients) and complications (16% patients) were also common.</p></div>","PeriodicalId":13384,"journal":{"name":"Indian heart journal","volume":"76 2","pages":"Pages 118-122"},"PeriodicalIF":1.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143500/pdf/","citationCount":"0","resultStr":"{\"title\":\"Implantable cardioverter defibrillators for primary prevention in cardiomyopathies\",\"authors\":\"Vineetha Kanneganti , Ajay Bahl , Manoj Kumar Rohit , Saurabh Mehrotra\",\"doi\":\"10.1016/j.ihj.2024.03.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Implantable cardioverter defibrillators (ICD) are often used as primary prevention strategy for sudden cardiac death (SCD) in young individuals. This study analyzed appropriate therapies, complications and inappropriate shocks in the real-world Indian population.</p></div><div><h3>Methods</h3><p>All patients in the cardiomyopathy cohort under follow up who had ICD implanted as a primary prevention strategy were studied. The objective was to assess the incidence of appropriate ICD therapies, inappropriate therapies and complications. ICD was interrogated and stored electrograms analyzed. Underlying arrhythmia or conditions resulting in appropriate or inappropriate ICD therapy were studied. Correlation and regression studies was done to assess for the predictors of appropriate therapy.</p></div><div><h3>Results</h3><p>Fifty patients were followed up for a mean follow-up duration of 4.4 ± 3.1 years with total follow up of 220.2 patient years. Appropriate ICD therapy was delivered in 16 out of 50 (32%) patients, with 65 appropriate therapies (median 2 per patient, range: 0–20). Inappropriate therapy delivered in 7 of the 50 (14%) patients, with 44 inappropriate therapies (median 5 per patient, range: 0–20). Complications occurred in 8 of the 50 (16%) patients. Overall, the rate of appropriate therapy was 29.5 per 100 patient years, that of inappropriate therapy was 19.9 per 100 patient years and the rate of complications was 3.6 per 100 patient years.</p></div><div><h3>Conclusions</h3><p>When implanted for primary prevention in patients with cardiomyopathies over a mean period of 4.4 ± 3.1 years, appropriate ICD therapy was delivered in 32% patients. However, inappropriate therapy (14% patients) and complications (16% patients) were also common.</p></div>\",\"PeriodicalId\":13384,\"journal\":{\"name\":\"Indian heart journal\",\"volume\":\"76 2\",\"pages\":\"Pages 118-122\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143500/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian heart journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0019483224000506\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian heart journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019483224000506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Implantable cardioverter defibrillators for primary prevention in cardiomyopathies
Background
Implantable cardioverter defibrillators (ICD) are often used as primary prevention strategy for sudden cardiac death (SCD) in young individuals. This study analyzed appropriate therapies, complications and inappropriate shocks in the real-world Indian population.
Methods
All patients in the cardiomyopathy cohort under follow up who had ICD implanted as a primary prevention strategy were studied. The objective was to assess the incidence of appropriate ICD therapies, inappropriate therapies and complications. ICD was interrogated and stored electrograms analyzed. Underlying arrhythmia or conditions resulting in appropriate or inappropriate ICD therapy were studied. Correlation and regression studies was done to assess for the predictors of appropriate therapy.
Results
Fifty patients were followed up for a mean follow-up duration of 4.4 ± 3.1 years with total follow up of 220.2 patient years. Appropriate ICD therapy was delivered in 16 out of 50 (32%) patients, with 65 appropriate therapies (median 2 per patient, range: 0–20). Inappropriate therapy delivered in 7 of the 50 (14%) patients, with 44 inappropriate therapies (median 5 per patient, range: 0–20). Complications occurred in 8 of the 50 (16%) patients. Overall, the rate of appropriate therapy was 29.5 per 100 patient years, that of inappropriate therapy was 19.9 per 100 patient years and the rate of complications was 3.6 per 100 patient years.
Conclusions
When implanted for primary prevention in patients with cardiomyopathies over a mean period of 4.4 ± 3.1 years, appropriate ICD therapy was delivered in 32% patients. However, inappropriate therapy (14% patients) and complications (16% patients) were also common.
期刊介绍:
Indian Heart Journal (IHJ) is the official peer-reviewed open access journal of Cardiological Society of India and accepts articles for publication from across the globe. The journal aims to promote high quality research and serve as a platform for dissemination of scientific information in cardiology with particular focus on South Asia. The journal aims to publish cutting edge research in the field of clinical as well as non-clinical cardiology - including cardiovascular medicine and surgery. Some of the topics covered are Heart Failure, Coronary Artery Disease, Hypertension, Interventional Cardiology, Cardiac Surgery, Valvular Heart Disease, Pulmonary Hypertension and Infective Endocarditis. IHJ open access invites original research articles, research briefs, perspective, case reports, case vignette, cardiovascular images, cardiovascular graphics, research letters, correspondence, reader forum, and interesting photographs, for publication. IHJ open access also publishes theme-based special issues and abstracts of papers presented at the annual conference of the Cardiological Society of India.