{"title":"用于手部卫生的集成共面介质阻挡放电装置的特性和性能","authors":"Shiyun Liu, Haosheng Jin, Yunyang Lu, Li Wan, Danhua Mei, Zhi Fang","doi":"10.1002/ppap.202400011","DOIUrl":null,"url":null,"abstract":"A touchable plasma device based on coplanar dielectric barrier discharge (CDBD) is designed for hand hygiene. The biological safety is evaluated from the aspects of electrical and thermal properties. The peak value of current through the human body (~3.5 mA) and the highest device surface temperature (~40°C) are lower than the threshold of perception current and thermal damage temperature, respectively. The typical bacteria that are present on our hands in daily life <jats:italic>Escherichia coli</jats:italic> and <jats:italic>Staphylococcus aureus</jats:italic> are selected to verify the sterilization performance of the device. The results of human contact safety evaluation and sterilization test have demonstrated that this proposed CDBD device is reliable and user‐friendly for applications in hand hygiene.","PeriodicalId":20135,"journal":{"name":"Plasma Processes and Polymers","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characteristics and performance of an integrated coplanar dielectric barrier discharge device for hand hygiene\",\"authors\":\"Shiyun Liu, Haosheng Jin, Yunyang Lu, Li Wan, Danhua Mei, Zhi Fang\",\"doi\":\"10.1002/ppap.202400011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A touchable plasma device based on coplanar dielectric barrier discharge (CDBD) is designed for hand hygiene. The biological safety is evaluated from the aspects of electrical and thermal properties. The peak value of current through the human body (~3.5 mA) and the highest device surface temperature (~40°C) are lower than the threshold of perception current and thermal damage temperature, respectively. The typical bacteria that are present on our hands in daily life <jats:italic>Escherichia coli</jats:italic> and <jats:italic>Staphylococcus aureus</jats:italic> are selected to verify the sterilization performance of the device. The results of human contact safety evaluation and sterilization test have demonstrated that this proposed CDBD device is reliable and user‐friendly for applications in hand hygiene.\",\"PeriodicalId\":20135,\"journal\":{\"name\":\"Plasma Processes and Polymers\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasma Processes and Polymers\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1002/ppap.202400011\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Processes and Polymers","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1002/ppap.202400011","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
Characteristics and performance of an integrated coplanar dielectric barrier discharge device for hand hygiene
A touchable plasma device based on coplanar dielectric barrier discharge (CDBD) is designed for hand hygiene. The biological safety is evaluated from the aspects of electrical and thermal properties. The peak value of current through the human body (~3.5 mA) and the highest device surface temperature (~40°C) are lower than the threshold of perception current and thermal damage temperature, respectively. The typical bacteria that are present on our hands in daily life Escherichia coli and Staphylococcus aureus are selected to verify the sterilization performance of the device. The results of human contact safety evaluation and sterilization test have demonstrated that this proposed CDBD device is reliable and user‐friendly for applications in hand hygiene.
期刊介绍:
Plasma Processes & Polymers focuses on the interdisciplinary field of low temperature plasma science, covering both experimental and theoretical aspects of fundamental and applied research in materials science, physics, chemistry and engineering in the area of plasma sources and plasma-based treatments.