{"title":"利用 cn-85 、cr-39 和 lr-115 核轨道探测器进行紫外线辐射剂量测定","authors":"Firas Al-Jomaily, H. Al-jobouri, Ahmed Mheemeed","doi":"10.24996/iraqijournalofscience.v53i3.12754","DOIUrl":null,"url":null,"abstract":"Ultraviolet radiation dosimetry was determined by using CN-85 , CR-39 ,LR-115 nuclear track detectors – NTD with measuring of ; number of track-NT , etching time-TB , nuclear track diameter - DT and etching velocity -VD . By this study appear the increasing in etching time-TB of NTD samples which irradiated by UV-radiation do not pure effect on the number of track - NT , comparing with un-irradiated samples . The increasing in UV-irradiation make decreasing in etching time- Topt for CR-39 , CN-85 , LR-115 nuclear track detectors with percent of 20% , 25% , 50% respectively , comparing with un– irradiated sample at the radiation dose 3.77x103 erg /mm2 . . The increasing of irradiation dose make increasing in nuclear track diameter-DT with increase in etching time-TB at the radiation dose 300x103erg / mm2 for LR-115 detector . This study showing there was increasing in the percent value of etching velocity -VB with increasing inradiation dose for CR-39 , CN-85 . The increasing in nuclear track diameter- DTwith increasing in radiation dose was appearing as a resulted of energy of radiationand producted free radicals which interact with chemical etching solution . Thisstudy optioned by using nuclear track detectors CN-85 , CR-39 for determinationthe radiation dosimetry through measuring of etching velocity -VB butter than LR-115 detector","PeriodicalId":14698,"journal":{"name":"Iraqi Journal of Science","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ULTRAVIOLET RADIATION DOSIMETRY BY USING OF CN-85 , CR-39, LR-115 NUCLEAR TRACK DETECTORS\",\"authors\":\"Firas Al-Jomaily, H. Al-jobouri, Ahmed Mheemeed\",\"doi\":\"10.24996/iraqijournalofscience.v53i3.12754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ultraviolet radiation dosimetry was determined by using CN-85 , CR-39 ,LR-115 nuclear track detectors – NTD with measuring of ; number of track-NT , etching time-TB , nuclear track diameter - DT and etching velocity -VD . By this study appear the increasing in etching time-TB of NTD samples which irradiated by UV-radiation do not pure effect on the number of track - NT , comparing with un-irradiated samples . The increasing in UV-irradiation make decreasing in etching time- Topt for CR-39 , CN-85 , LR-115 nuclear track detectors with percent of 20% , 25% , 50% respectively , comparing with un– irradiated sample at the radiation dose 3.77x103 erg /mm2 . . The increasing of irradiation dose make increasing in nuclear track diameter-DT with increase in etching time-TB at the radiation dose 300x103erg / mm2 for LR-115 detector . This study showing there was increasing in the percent value of etching velocity -VB with increasing inradiation dose for CR-39 , CN-85 . The increasing in nuclear track diameter- DTwith increasing in radiation dose was appearing as a resulted of energy of radiationand producted free radicals which interact with chemical etching solution . Thisstudy optioned by using nuclear track detectors CN-85 , CR-39 for determinationthe radiation dosimetry through measuring of etching velocity -VB butter than LR-115 detector\",\"PeriodicalId\":14698,\"journal\":{\"name\":\"Iraqi Journal of Science\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iraqi Journal of Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24996/iraqijournalofscience.v53i3.12754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Earth and Planetary Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iraqi Journal of Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24996/iraqijournalofscience.v53i3.12754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Earth and Planetary Sciences","Score":null,"Total":0}
ULTRAVIOLET RADIATION DOSIMETRY BY USING OF CN-85 , CR-39, LR-115 NUCLEAR TRACK DETECTORS
Ultraviolet radiation dosimetry was determined by using CN-85 , CR-39 ,LR-115 nuclear track detectors – NTD with measuring of ; number of track-NT , etching time-TB , nuclear track diameter - DT and etching velocity -VD . By this study appear the increasing in etching time-TB of NTD samples which irradiated by UV-radiation do not pure effect on the number of track - NT , comparing with un-irradiated samples . The increasing in UV-irradiation make decreasing in etching time- Topt for CR-39 , CN-85 , LR-115 nuclear track detectors with percent of 20% , 25% , 50% respectively , comparing with un– irradiated sample at the radiation dose 3.77x103 erg /mm2 . . The increasing of irradiation dose make increasing in nuclear track diameter-DT with increase in etching time-TB at the radiation dose 300x103erg / mm2 for LR-115 detector . This study showing there was increasing in the percent value of etching velocity -VB with increasing inradiation dose for CR-39 , CN-85 . The increasing in nuclear track diameter- DTwith increasing in radiation dose was appearing as a resulted of energy of radiationand producted free radicals which interact with chemical etching solution . Thisstudy optioned by using nuclear track detectors CN-85 , CR-39 for determinationthe radiation dosimetry through measuring of etching velocity -VB butter than LR-115 detector