评估在配水交叉路口下游安置住户接头的最小距离

R. Mompremier, Jersain Gómez-Núñez, R. Guadarrama-Pérez, J. Ramírez-Muñoz
{"title":"评估在配水交叉路口下游安置住户接头的最小距离","authors":"R. Mompremier, Jersain Gómez-Núñez, R. Guadarrama-Pérez, J. Ramírez-Muñoz","doi":"10.2166/aqua.2024.296","DOIUrl":null,"url":null,"abstract":"\n \n This study investigates the solute (chlorine residual) mixing phenomena downstream of a cross junction, considering its critical role in household connections. Experiments were conducted under turbulent flow conditions in a cross junction with two inlets at 90°, varying flow and chlorine concentration ratios at the inlets, i.e., simulating conditions commonly found in real water distribution systems. Results show that outlet chlorine concentrations primarily depend on the flow ratio at the inlets as well as on the inlet chlorine concentrations. Three-dimensional simulations were conducted to predict chlorine concentrations downstream of the cross junction. To evaluate the degree of downstream mixing, the percent coefficient of variation of tracer concentration (%CV) as a function of the axial position at different chlorine and flow ratios was computed from simulations. It was found that the flow ratio strongly affects it at downstream distances less than 50 pipe diameters, whereas the inlet chlorine concentration ratio has a weak effect. A novel correlation was derived as a function of flow ratio to ascertain the minimal distance for achieving the intended mixing level of %CV = 5 downstream of cross junctions. This correlation holds potential as a criterion for household connection location within water distribution networks for high-quality water delivery.","PeriodicalId":513288,"journal":{"name":"AQUA — Water Infrastructure, Ecosystems and Society","volume":"2 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of the minimal distance for placing household connections downstream of water distribution cross junctions\",\"authors\":\"R. Mompremier, Jersain Gómez-Núñez, R. Guadarrama-Pérez, J. Ramírez-Muñoz\",\"doi\":\"10.2166/aqua.2024.296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n \\n This study investigates the solute (chlorine residual) mixing phenomena downstream of a cross junction, considering its critical role in household connections. Experiments were conducted under turbulent flow conditions in a cross junction with two inlets at 90°, varying flow and chlorine concentration ratios at the inlets, i.e., simulating conditions commonly found in real water distribution systems. Results show that outlet chlorine concentrations primarily depend on the flow ratio at the inlets as well as on the inlet chlorine concentrations. Three-dimensional simulations were conducted to predict chlorine concentrations downstream of the cross junction. To evaluate the degree of downstream mixing, the percent coefficient of variation of tracer concentration (%CV) as a function of the axial position at different chlorine and flow ratios was computed from simulations. It was found that the flow ratio strongly affects it at downstream distances less than 50 pipe diameters, whereas the inlet chlorine concentration ratio has a weak effect. A novel correlation was derived as a function of flow ratio to ascertain the minimal distance for achieving the intended mixing level of %CV = 5 downstream of cross junctions. This correlation holds potential as a criterion for household connection location within water distribution networks for high-quality water delivery.\",\"PeriodicalId\":513288,\"journal\":{\"name\":\"AQUA — Water Infrastructure, Ecosystems and Society\",\"volume\":\"2 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AQUA — Water Infrastructure, Ecosystems and Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/aqua.2024.296\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AQUA — Water Infrastructure, Ecosystems and Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/aqua.2024.296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

考虑到十字交叉口在家庭连接中的关键作用,本研究调查了十字交叉口下游的溶质(余氯)混合现象。实验是在两个入口成 90°的十字交叉口的紊流条件下进行的,改变了入口处的流量和余氯浓度比,即模拟了实际输水系统中常见的条件。结果表明,出水口的氯浓度主要取决于进水口的流量比和进水口的氯浓度。我们进行了三维模拟,以预测交叉口下游的氯浓度。为了评估下游的混合程度,模拟计算了不同氯浓度和流量比时示踪剂浓度的百分比变化系数(%CV)与轴向位置的函数关系。结果发现,在下游距离小于 50 管径时,流量比对其影响很大,而入口氯浓度比的影响较小。作为流量比的函数,得出了一种新的相关关系,以确定在交叉口下游达到预期混合水平 %CV = 5 的最小距离。这种相关性可作为优质供水配水管网中家庭连接位置的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of the minimal distance for placing household connections downstream of water distribution cross junctions
This study investigates the solute (chlorine residual) mixing phenomena downstream of a cross junction, considering its critical role in household connections. Experiments were conducted under turbulent flow conditions in a cross junction with two inlets at 90°, varying flow and chlorine concentration ratios at the inlets, i.e., simulating conditions commonly found in real water distribution systems. Results show that outlet chlorine concentrations primarily depend on the flow ratio at the inlets as well as on the inlet chlorine concentrations. Three-dimensional simulations were conducted to predict chlorine concentrations downstream of the cross junction. To evaluate the degree of downstream mixing, the percent coefficient of variation of tracer concentration (%CV) as a function of the axial position at different chlorine and flow ratios was computed from simulations. It was found that the flow ratio strongly affects it at downstream distances less than 50 pipe diameters, whereas the inlet chlorine concentration ratio has a weak effect. A novel correlation was derived as a function of flow ratio to ascertain the minimal distance for achieving the intended mixing level of %CV = 5 downstream of cross junctions. This correlation holds potential as a criterion for household connection location within water distribution networks for high-quality water delivery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Photocatalytic performance of TiO2 modified with graphene derivatives and Fe (Ⅲ) at different thermal reduction temperatures Why do people save water? A systematic review of household water consumption behaviour in times of water availability uncertainty The socio-technical short-term implications of drinking water hoarding on supply reliability Hydraulic investigation of flows at high-head overflow spillway with multiple aerators: a physical and numerical study of Mohmand Dam, Pakistan Water quality ensemble prediction model for the urban water reservoir based on the hybrid long short-term memory (LSTM) network analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1