办公楼内空气传播微生物的公共卫生风险评估和种类划分

IF 3.9 3区 环境科学与生态学 Q2 ENGINEERING, CHEMICAL Journal of Aerosol Science Pub Date : 2024-03-20 DOI:10.1016/j.jaerosci.2024.106362
Abhaysinh R. Salunkhe, Swapnil Dudhwadkar, Neenu P. Raju, Shalini Tandon
{"title":"办公楼内空气传播微生物的公共卫生风险评估和种类划分","authors":"Abhaysinh R. Salunkhe,&nbsp;Swapnil Dudhwadkar,&nbsp;Neenu P. Raju,&nbsp;Shalini Tandon","doi":"10.1016/j.jaerosci.2024.106362","DOIUrl":null,"url":null,"abstract":"<div><p>This study focuses on speciation of air borne microbes in an office building and health impacts of these microbes in terms of Quantitative Microbial Risk Assessment (QMRA), Hazard Quotient (HQ) and Hazard Index (HI). This is important in the wake of Sustainability Development Goal 3 (Public Health and well-being) specially when there is a lack of standards in terms of microbial air quality in office buildings where people spend 8–10 h indoors. Air borne bacterial and fungal species in different floors of the office building with varying occupancy and work profile were identified. The load of bacterial count on an average for the entire building was found to be 1917 CFU/m3. Overall, Gram-positive bacteria were predominant (&gt;53%). Based on V3–V4 sequencing <em>Staphylococcus scuiri</em> (causing UTIs) was the most abundant (93.7%) and other bacterial species found were <em>Lactobacillus hamsteri, Prevotella copri, Bacteroides plebeius Faecalibacterium prausnitzii, Bacillus coagulans</em> (gut commensals), <em>Shigella boydii</em> (causes bacillary dysentery), and <em>Propionibacterium acnes</em> (acne producing). Fungal load was 4000 CFU/m3. Based on ITS sequencing <em>Aspergillus</em> (45.6%) was the dominant fungus and other fungi found were <em>Cunninghamella</em>, <em>Lichtheimia, Fusarium,</em> and <em>Circinella Grammothele</em>, <em>Chondrostereum</em>, and <em>Pseudolagarobasidium</em>, <em>Candida</em> sp., <em>Chondrostereum, Sarocladium</em>. The QMRA of gram-negative air borne bacteria showed a high disease burden, well over the WHO benchmark values even though Hazard Quotient (HQ) and Hazard Index (HI) was found to be negligible. These findings can contribute to the development of guidelines for seemingly safe workplaces that may harbour disease-causing microbes and calls for an immediate attention from policy makers as it is a major cause of concern for public health.</p></div>","PeriodicalId":14880,"journal":{"name":"Journal of Aerosol Science","volume":null,"pages":null},"PeriodicalIF":3.9000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Public health risk assessment and speciation of air-borne microorganisms in an office building\",\"authors\":\"Abhaysinh R. Salunkhe,&nbsp;Swapnil Dudhwadkar,&nbsp;Neenu P. Raju,&nbsp;Shalini Tandon\",\"doi\":\"10.1016/j.jaerosci.2024.106362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study focuses on speciation of air borne microbes in an office building and health impacts of these microbes in terms of Quantitative Microbial Risk Assessment (QMRA), Hazard Quotient (HQ) and Hazard Index (HI). This is important in the wake of Sustainability Development Goal 3 (Public Health and well-being) specially when there is a lack of standards in terms of microbial air quality in office buildings where people spend 8–10 h indoors. Air borne bacterial and fungal species in different floors of the office building with varying occupancy and work profile were identified. The load of bacterial count on an average for the entire building was found to be 1917 CFU/m3. Overall, Gram-positive bacteria were predominant (&gt;53%). Based on V3–V4 sequencing <em>Staphylococcus scuiri</em> (causing UTIs) was the most abundant (93.7%) and other bacterial species found were <em>Lactobacillus hamsteri, Prevotella copri, Bacteroides plebeius Faecalibacterium prausnitzii, Bacillus coagulans</em> (gut commensals), <em>Shigella boydii</em> (causes bacillary dysentery), and <em>Propionibacterium acnes</em> (acne producing). Fungal load was 4000 CFU/m3. Based on ITS sequencing <em>Aspergillus</em> (45.6%) was the dominant fungus and other fungi found were <em>Cunninghamella</em>, <em>Lichtheimia, Fusarium,</em> and <em>Circinella Grammothele</em>, <em>Chondrostereum</em>, and <em>Pseudolagarobasidium</em>, <em>Candida</em> sp., <em>Chondrostereum, Sarocladium</em>. The QMRA of gram-negative air borne bacteria showed a high disease burden, well over the WHO benchmark values even though Hazard Quotient (HQ) and Hazard Index (HI) was found to be negligible. These findings can contribute to the development of guidelines for seemingly safe workplaces that may harbour disease-causing microbes and calls for an immediate attention from policy makers as it is a major cause of concern for public health.</p></div>\",\"PeriodicalId\":14880,\"journal\":{\"name\":\"Journal of Aerosol Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Aerosol Science\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0021850224000296\",\"RegionNum\":3,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aerosol Science","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021850224000296","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究的重点是办公楼空气中微生物的种类,以及这些微生物在微生物风险定量评估(QMRA)、危害商数(HQ)和危害指数(HI)方面对健康的影响。这对于实现可持续发展目标 3(公众健康和福祉)非常重要,尤其是当人们在室内度过 8-10 个小时的办公楼缺乏微生物空气质量标准时。我们对办公楼不同楼层的不同入住率和工作情况下空气中的细菌和真菌种类进行了鉴定。结果发现,整栋大楼的平均细菌数量为 1917 CFU/m3。总体而言,革兰氏阳性细菌占主导地位(53%)。根据 V3-V4 测序,数量最多的细菌是 Staphylococcus scuiri(导致尿道炎)(93.7%),其他细菌种类包括 Lactobacillus hamsteri、Prevotella copri、Bacteroides plebeius Faecalibacterium prausnitzii、Bacillus coagulans(肠道共生菌)、Shigella boydii(导致细菌性痢疾)和 Propionibacterium acnes(产生痤疮)。真菌数量为 4000 CFU/m3。根据 ITS 测序,曲霉(45.6%)是最主要的真菌,其他真菌包括秃霉(Cunninghamella)、Lichtheimia、镰刀菌(Fusarium)、Circinella Grammothele、Chondrostereum、Pseudolagarobasidium、念珠菌(Candida sp.)、Chondrostereum、Sarocladium。革兰氏阴性空气传播细菌的 QMRA 显示了很高的疾病负担,远远超过了世界卫生组织的基准值,尽管发现危害商数(HQ)和危害指数(HI)微不足道。这些发现有助于为看似安全的工作场所制定指导方针,因为这些工作场所可能会滋生致病微生物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Public health risk assessment and speciation of air-borne microorganisms in an office building

This study focuses on speciation of air borne microbes in an office building and health impacts of these microbes in terms of Quantitative Microbial Risk Assessment (QMRA), Hazard Quotient (HQ) and Hazard Index (HI). This is important in the wake of Sustainability Development Goal 3 (Public Health and well-being) specially when there is a lack of standards in terms of microbial air quality in office buildings where people spend 8–10 h indoors. Air borne bacterial and fungal species in different floors of the office building with varying occupancy and work profile were identified. The load of bacterial count on an average for the entire building was found to be 1917 CFU/m3. Overall, Gram-positive bacteria were predominant (>53%). Based on V3–V4 sequencing Staphylococcus scuiri (causing UTIs) was the most abundant (93.7%) and other bacterial species found were Lactobacillus hamsteri, Prevotella copri, Bacteroides plebeius Faecalibacterium prausnitzii, Bacillus coagulans (gut commensals), Shigella boydii (causes bacillary dysentery), and Propionibacterium acnes (acne producing). Fungal load was 4000 CFU/m3. Based on ITS sequencing Aspergillus (45.6%) was the dominant fungus and other fungi found were Cunninghamella, Lichtheimia, Fusarium, and Circinella Grammothele, Chondrostereum, and Pseudolagarobasidium, Candida sp., Chondrostereum, Sarocladium. The QMRA of gram-negative air borne bacteria showed a high disease burden, well over the WHO benchmark values even though Hazard Quotient (HQ) and Hazard Index (HI) was found to be negligible. These findings can contribute to the development of guidelines for seemingly safe workplaces that may harbour disease-causing microbes and calls for an immediate attention from policy makers as it is a major cause of concern for public health.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Aerosol Science
Journal of Aerosol Science 环境科学-工程:化工
CiteScore
8.80
自引率
8.90%
发文量
127
审稿时长
35 days
期刊介绍: Founded in 1970, the Journal of Aerosol Science considers itself the prime vehicle for the publication of original work as well as reviews related to fundamental and applied aerosol research, as well as aerosol instrumentation. Its content is directed at scientists working in engineering disciplines, as well as physics, chemistry, and environmental sciences. The editors welcome submissions of papers describing recent experimental, numerical, and theoretical research related to the following topics: 1. Fundamental Aerosol Science. 2. Applied Aerosol Science. 3. Instrumentation & Measurement Methods.
期刊最新文献
Non-linear optics for an online probing of the specific surface area of nanoparticles in the aerosol phase Computational and experimental investigation of an aerosol extraction device for use in dentistry Collision frequencies across collision regimes in two-component systems Enhanced organic aerosol formation induced by inorganic aerosol formed in laboratory photochemical experiments Development of a source-term migration model for a large bubble formed in a core disruptive accident
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1