Hao Liu;Fengwei Liang;Tianyu Hu;Jichao Hong;Huimin Ma
{"title":"基于门控递归单元的多尺度融合模型,用于提高电池储能系统的充电状态预测精度","authors":"Hao Liu;Fengwei Liang;Tianyu Hu;Jichao Hong;Huimin Ma","doi":"10.35833/MPCE.2023.000726","DOIUrl":null,"url":null,"abstract":"Accurate prediction of the state-of-charge (SOC) of battery energy storage system (BESS) is critical for its safety and lifespan in electric vehicles. To overcome the imbalance of existing methods between multi-scale feature fusion and global feature extraction, this paper introduces a novel multi-scale fusion (MSF) model based on gated recurrent unit (GRU), which is specifically designed for complex multi-step SOC prediction in practical BESSs. Pearson correlation analysis is first employed to identify SOC-related parameters. These parameters are then input into a multi-layer GRU for point-wise feature extraction. Concurrently, the parameters undergo patching before entering a dual-stage multi-layer GRU, thus enabling the model to capture nuanced information across varying time intervals. Ultimately, by means of adaptive weight fusion and a fully connected network, multi-step SOC predictions are rendered. Following extensive validation over multiple days, it is illustrated that the proposed model achieves an absolute error of less than 1.5% in real-time SOC prediction.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"12 2","pages":"405-414"},"PeriodicalIF":5.7000,"publicationDate":"2024-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10478435","citationCount":"0","resultStr":"{\"title\":\"Multi-Scale Fusion Model Based on Gated Recurrent Unit for Enhancing Prediction Accuracy of State-of-Charge in Battery Energy Storage Systems\",\"authors\":\"Hao Liu;Fengwei Liang;Tianyu Hu;Jichao Hong;Huimin Ma\",\"doi\":\"10.35833/MPCE.2023.000726\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate prediction of the state-of-charge (SOC) of battery energy storage system (BESS) is critical for its safety and lifespan in electric vehicles. To overcome the imbalance of existing methods between multi-scale feature fusion and global feature extraction, this paper introduces a novel multi-scale fusion (MSF) model based on gated recurrent unit (GRU), which is specifically designed for complex multi-step SOC prediction in practical BESSs. Pearson correlation analysis is first employed to identify SOC-related parameters. These parameters are then input into a multi-layer GRU for point-wise feature extraction. Concurrently, the parameters undergo patching before entering a dual-stage multi-layer GRU, thus enabling the model to capture nuanced information across varying time intervals. Ultimately, by means of adaptive weight fusion and a fully connected network, multi-step SOC predictions are rendered. Following extensive validation over multiple days, it is illustrated that the proposed model achieves an absolute error of less than 1.5% in real-time SOC prediction.\",\"PeriodicalId\":51326,\"journal\":{\"name\":\"Journal of Modern Power Systems and Clean Energy\",\"volume\":\"12 2\",\"pages\":\"405-414\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10478435\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Modern Power Systems and Clean Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10478435/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10478435/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Multi-Scale Fusion Model Based on Gated Recurrent Unit for Enhancing Prediction Accuracy of State-of-Charge in Battery Energy Storage Systems
Accurate prediction of the state-of-charge (SOC) of battery energy storage system (BESS) is critical for its safety and lifespan in electric vehicles. To overcome the imbalance of existing methods between multi-scale feature fusion and global feature extraction, this paper introduces a novel multi-scale fusion (MSF) model based on gated recurrent unit (GRU), which is specifically designed for complex multi-step SOC prediction in practical BESSs. Pearson correlation analysis is first employed to identify SOC-related parameters. These parameters are then input into a multi-layer GRU for point-wise feature extraction. Concurrently, the parameters undergo patching before entering a dual-stage multi-layer GRU, thus enabling the model to capture nuanced information across varying time intervals. Ultimately, by means of adaptive weight fusion and a fully connected network, multi-step SOC predictions are rendered. Following extensive validation over multiple days, it is illustrated that the proposed model achieves an absolute error of less than 1.5% in real-time SOC prediction.
期刊介绍:
Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.