SuperMap 算法:一种用于绘制和消除高难度心律失常的高效、安全和准确的模式。

IF 1.6 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Future cardiology Pub Date : 2024-02-01 Epub Date: 2024-03-26 DOI:10.2217/fca-2023-0123
Charlie Lin, Andrew Nguyen, Ian Ling, Rod Partow-Navid, Steven Leung, Andrew Zadeh, Ivan Ho, Junaid Ab Zaman
{"title":"SuperMap 算法:一种用于绘制和消除高难度心律失常的高效、安全和准确的模式。","authors":"Charlie Lin, Andrew Nguyen, Ian Ling, Rod Partow-Navid, Steven Leung, Andrew Zadeh, Ivan Ho, Junaid Ab Zaman","doi":"10.2217/fca-2023-0123","DOIUrl":null,"url":null,"abstract":"<p><p>Even with the development of advanced catheter-based mapping systems, there remain several challenges in the electrophysiological evaluation and elimination of atrial arrhythmias. For instance, atrial tachycardias with irregular rates cannot be reliably mapped by systems that require stability in order to sequentially gather data points to be organized thereafter. Separately, these arrhythmias often arise following initial ablation for atrial fibrillation, posing logistic challenges. Here, we present the available literature summarizing the use of a non-contact mapping catheter, the AcQMap catheter, in conjunction with SuperMap, an algorithm that compiles a large number of non-contact data points from multiple catheter positions within the atria. These studies demonstrate the efficiency, safety and accuracy of this technology.</p>","PeriodicalId":12589,"journal":{"name":"Future cardiology","volume":"20 2","pages":"45-53"},"PeriodicalIF":1.6000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SuperMap algorithm: an efficient, safe and accurate modality for mapping and eliminating challenging cardiac arrhythmias.\",\"authors\":\"Charlie Lin, Andrew Nguyen, Ian Ling, Rod Partow-Navid, Steven Leung, Andrew Zadeh, Ivan Ho, Junaid Ab Zaman\",\"doi\":\"10.2217/fca-2023-0123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Even with the development of advanced catheter-based mapping systems, there remain several challenges in the electrophysiological evaluation and elimination of atrial arrhythmias. For instance, atrial tachycardias with irregular rates cannot be reliably mapped by systems that require stability in order to sequentially gather data points to be organized thereafter. Separately, these arrhythmias often arise following initial ablation for atrial fibrillation, posing logistic challenges. Here, we present the available literature summarizing the use of a non-contact mapping catheter, the AcQMap catheter, in conjunction with SuperMap, an algorithm that compiles a large number of non-contact data points from multiple catheter positions within the atria. These studies demonstrate the efficiency, safety and accuracy of this technology.</p>\",\"PeriodicalId\":12589,\"journal\":{\"name\":\"Future cardiology\",\"volume\":\"20 2\",\"pages\":\"45-53\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Future cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2217/fca-2023-0123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Future cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2217/fca-2023-0123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

即使开发出了先进的导管映射系统,在电生理评估和消除房性心律失常方面仍存在一些挑战。例如,心率不规则的房性心动过速无法通过系统进行可靠的映射,因为系统需要保持稳定才能按顺序收集数据点,然后进行整理。另外,这些心律失常往往出现在房颤的初始消融术之后,给后勤工作带来了挑战。在此,我们介绍了现有的文献,总结了非接触式绘图导管 AcQMap 导管与 SuperMap(一种从心房内多个导管位置汇编大量非接触式数据点的算法)的结合使用情况。这些研究证明了该技术的高效性、安全性和准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SuperMap algorithm: an efficient, safe and accurate modality for mapping and eliminating challenging cardiac arrhythmias.

Even with the development of advanced catheter-based mapping systems, there remain several challenges in the electrophysiological evaluation and elimination of atrial arrhythmias. For instance, atrial tachycardias with irregular rates cannot be reliably mapped by systems that require stability in order to sequentially gather data points to be organized thereafter. Separately, these arrhythmias often arise following initial ablation for atrial fibrillation, posing logistic challenges. Here, we present the available literature summarizing the use of a non-contact mapping catheter, the AcQMap catheter, in conjunction with SuperMap, an algorithm that compiles a large number of non-contact data points from multiple catheter positions within the atria. These studies demonstrate the efficiency, safety and accuracy of this technology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Future cardiology
Future cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.80
自引率
5.90%
发文量
87
期刊介绍: Research advances have contributed to improved outcomes across all specialties, but the rate of advancement in cardiology has been exceptional. Concurrently, the population of patients with cardiac conditions continues to grow and greater public awareness has increased patients" expectations of new drugs and devices. Future Cardiology (ISSN 1479-6678) reflects this new era of cardiology and highlights the new molecular approach to advancing cardiovascular therapy. Coverage will also reflect the major technological advances in bioengineering in cardiology in terms of advanced and robust devices, miniaturization, imaging, system modeling and information management issues.
期刊最新文献
Electrocardiographic and biochemical predictors of left ventricular remodeling early after ST-segment elevation myocardial infarction. Severe acute recoil following transcatheter aortic valve replacement with a self-expanding prosthesis in a heavily calcified bicuspid aortic valve. Single-center initial experience with a new pulsed-field ablation system: pulmonary vein isolation lesions and beyond. Soft drinks, fish oil and atrial fibrillation. Cardiovascular magnetic resonance versus echocardiography derived left ventricular ejection fraction for decision-making.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1