体重正常化对老年妇女肌肉横截面积和运动表现结果之间相关性的影响。

Medical ultrasonography Pub Date : 2024-06-21 Epub Date: 2024-01-30 DOI:10.11152/mu-4324
Ty B Palmer, Bailey M Palmer
{"title":"体重正常化对老年妇女肌肉横截面积和运动表现结果之间相关性的影响。","authors":"Ty B Palmer, Bailey M Palmer","doi":"10.11152/mu-4324","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Normalization is a method used to account for body mass in clinical practice and research. It is unclear if this method will improve the correlation between muscle cross-sectional area (CSA) and physical performance. We examined the correlations between quadriceps muscle morphology parameters and physical performance outcomes in older women. Material and methods: Twenty older women participated in this study. Ultrasound imaging was used to measure quadriceps muscle CSA and echo intensity. Muscle CSA was expressed as an absolute value (cm2) and as a relative value normalized to body mass (cm2/kg). Physical performance was assessed from timed up-and-go and 6-min walk tests.</p><p><strong>Results: </strong>Relative CSA was significantly related to timed up-and-go scores (r=-0.489, p=0.029) and 6-min walking speed (r=0.606, p=0.005), whereas absolute CSA was not significantly associated with these performances (r=-0.231, p=0.327 and r=0.373, p=0.105). There was a significant correlation between absolute CSA and body mass (r=0.456, p=0.043). There were also significant correlations between echo intensity and timed up-and-go scores (r=0.556, p=0.011) and 6-min walking speed (r=-0.484, p=0.031).</p><p><strong>Conclusions: </strong> Our study showed that relative CSA correlated better than absolute CSA with physical performance. These findings support the need to normalize measurements of muscle CSA to body mass in older adults.</p>","PeriodicalId":94138,"journal":{"name":"Medical ultrasonography","volume":" ","pages":"153-159"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of body mass normalization on the correlations between muscle cross-sectional area and physical performance outcomes in older women.\",\"authors\":\"Ty B Palmer, Bailey M Palmer\",\"doi\":\"10.11152/mu-4324\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Normalization is a method used to account for body mass in clinical practice and research. It is unclear if this method will improve the correlation between muscle cross-sectional area (CSA) and physical performance. We examined the correlations between quadriceps muscle morphology parameters and physical performance outcomes in older women. Material and methods: Twenty older women participated in this study. Ultrasound imaging was used to measure quadriceps muscle CSA and echo intensity. Muscle CSA was expressed as an absolute value (cm2) and as a relative value normalized to body mass (cm2/kg). Physical performance was assessed from timed up-and-go and 6-min walk tests.</p><p><strong>Results: </strong>Relative CSA was significantly related to timed up-and-go scores (r=-0.489, p=0.029) and 6-min walking speed (r=0.606, p=0.005), whereas absolute CSA was not significantly associated with these performances (r=-0.231, p=0.327 and r=0.373, p=0.105). There was a significant correlation between absolute CSA and body mass (r=0.456, p=0.043). There were also significant correlations between echo intensity and timed up-and-go scores (r=0.556, p=0.011) and 6-min walking speed (r=-0.484, p=0.031).</p><p><strong>Conclusions: </strong> Our study showed that relative CSA correlated better than absolute CSA with physical performance. These findings support the need to normalize measurements of muscle CSA to body mass in older adults.</p>\",\"PeriodicalId\":94138,\"journal\":{\"name\":\"Medical ultrasonography\",\"volume\":\" \",\"pages\":\"153-159\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical ultrasonography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11152/mu-4324\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical ultrasonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11152/mu-4324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:在临床实践和研究中,归一化是一种用于计算体重的方法。目前还不清楚这种方法能否改善肌肉横截面积(CSA)与运动表现之间的相关性。我们研究了老年女性股四头肌形态参数与体能表现结果之间的相关性。材料和方法20 名老年妇女参与了这项研究。超声波成像用于测量股四头肌CSA和回声强度。肌肉 CSA 以绝对值(cm2)和与体重(cm2/kg)归一化的相对值表示。体能通过定时起立行走和 6 分钟步行测试进行评估:结果:相对 CSA 与定时上下楼梯得分(r=-0.489,p=0.029)和 6 分钟步行速度(r=0.606,p=0.005)明显相关,而绝对 CSA 与这些表现无明显关联(r=-0.231,p=0.327 和 r=0.373,p=0.105)。绝对 CSA 与体重之间存在明显的相关性(r=0.456,p=0.043)。回声强度与定时上下楼评分(r=0.556,p=0.011)和 6 分钟步行速度(r=-0.484,p=0.031)之间也存在明显的相关性: 我们的研究表明,相对 CSA 比绝对 CSA 与体能表现的相关性更好。结论:我们的研究表明,相对 CSA 比绝对 CSA 与体能表现的相关性更好。这些研究结果支持了将老年人肌肉 CSA 测量值与体重正常化的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of body mass normalization on the correlations between muscle cross-sectional area and physical performance outcomes in older women.

Aims: Normalization is a method used to account for body mass in clinical practice and research. It is unclear if this method will improve the correlation between muscle cross-sectional area (CSA) and physical performance. We examined the correlations between quadriceps muscle morphology parameters and physical performance outcomes in older women. Material and methods: Twenty older women participated in this study. Ultrasound imaging was used to measure quadriceps muscle CSA and echo intensity. Muscle CSA was expressed as an absolute value (cm2) and as a relative value normalized to body mass (cm2/kg). Physical performance was assessed from timed up-and-go and 6-min walk tests.

Results: Relative CSA was significantly related to timed up-and-go scores (r=-0.489, p=0.029) and 6-min walking speed (r=0.606, p=0.005), whereas absolute CSA was not significantly associated with these performances (r=-0.231, p=0.327 and r=0.373, p=0.105). There was a significant correlation between absolute CSA and body mass (r=0.456, p=0.043). There were also significant correlations between echo intensity and timed up-and-go scores (r=0.556, p=0.011) and 6-min walking speed (r=-0.484, p=0.031).

Conclusions:  Our study showed that relative CSA correlated better than absolute CSA with physical performance. These findings support the need to normalize measurements of muscle CSA to body mass in older adults.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic accuracy of transcranial ultrasonography for detecting stenosis in patients with acute ischaemic stroke: a systematic review and meta-analysis. Pancreatic cancer liver metastasis mimicking focal nodular hyperplasia. A case report. The impact of bowel preparation on MRI scans for confirming rectosigmoid endometriosis detected by transvaginal ultrasonography. Advancements and challenges in Shear-Wave Elastography of tendons: a comprehensive review. An [illustrative] update on pediatric emergency ultrasound: part 3 - cerebral, musculoskeletal and other applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1